Mounting and Operating Instructions DualGuard-S ESF30 KV
40071860406 (A) March 2022 www.eaton.com
2 Safety
2.4 Responsibility of the operator
These operating instructions must be kept in the immediate
vicinity of the unit and must be accessible at all times to
persons working on and with the unit. The unit may only be
operated if it is in a technically perfect and operationally safe
condition. The unit must be checked for integrity before each
start-up. The information in the operating instructions must
be followed completely and without restriction!
2.5 Requirements for the personnel
These operating instructions must be read and understood in
the immediate vicinity of the appliance and only authorised
and trained personnel may work with the appliance. The
personnel must have received instruction on any hazards that
may occur. Qualified personnel are those who, on the basis
of their technical training, knowledge and experience as well
as knowledge of the relevant regulations, are able to assess
the work assigned to them and recognise possible dangers.
2.6 Occupational safety
By following the safety information and instructions in this
manual can prevent personal injury and damage during work
with and on the unit can be avoided.
The electrical distribution board with function maintenance
type DualGuard-S ESF30 is used for the battery-supported
monitoring and power supply for emergency lighting. It may
only be:
- used as intended and
- be used in a safe and proper condition.
used in a safe condition. When handling the products and
for the correct the cable entry, please follow these operating
instructions exactly. Any other use is considered improper.
CEAG Notlichtsysteme is not liable for any damage or con-
sequential damage resulting from this.
2.2 Contents of the assembly and installation
instructions
Every person who is assigned to carry out work on or with
the unit must have read and understood the operating instruc-
tions before starting work on the unit. This also applies if the
person concerned has already worked with such a device
or similar devices or has been trained by the manufacturer.
2.3 Modifications and conversions to the
unit
To avoid hazards and to ensure optimum performance, no mo-
difications, additions or conversions may be made to the unit
that have not been expressly approved by the manufacturer..
Type
DualGuard-S
ESF30 SOU5
DualGuard-S
ESF30 SOU4 IO
DualGuard-S
ESF30 SOU3
DualGuard-S
ESF30 SOU2
DualGuard-S
ESF30 SOU1
Certificates
Empty enclosure
DIBT
DIBT
DIBT
DIBT
DIBT
Fire exposure
from outside (min)
30
30
30
30
30
Housing data
Housing
Fire protection panels
Fire protection panels
Fire protection panels
Fire protection panels
Fire protection panels
Degree of protection
IP54
IP54
IP54
IP54
IP54
Protection class
II
II
II
II
II
Dimensions
(H x W x D in mm)
1228 x 478 x 295
1228 x 478 x 295
928 x 478 x 295
778 x 478 x 295
628 x 478 x 295
Weight (kg) Raw cabinet
103
103
80
69
60
Closing
Swivelling lever with
Double pin
Swivelling lever with
Double pin
Swivelling lever with
Double pin
Swivelling lever with
Double pin
Swivelling lever with
Double pin
Electrical data
Rated voltage
230 V 50/60 Hz
230 V 50/60 Hz
230 V 50/60 Hz
230 V 50/60 Hz
230 V 50/60 Hz
Number of module slots
5
4
3
2
1
Max. Cable cross-section
End circuits (mm²)
4
4
4
4
4
Max. Individual conductor
cross-section (mm²)
10
10
10
10
10
Max. Total conductor
cross-section (mm²)
143
248
113
98
83
3 Technical data