Eaton Cutler-Hammer Modbus mMINT Скачать руководство пользователя страница 13

I.L. 66A7508H05

Page 13

Effective September 2003

Objects  -  (complete list)

Register Number

Modbus Address

INCOM Products -  (partial list)

Name

numeric

Units

IEEE

float

Fixed

point

(FP)

IEEE

float

(hex)

Fixed

point

(FP)

(hex)

FP sc

ale f

act

or

IQ-

200

D

P

-4

000

IQ A

n

al

yz

er

IQ Dat

a

IQ Dat

a

 P

lus

Digit

rip OPTIM

 5

5

0

Digit

rip OPTIM

 7

5

0

Digit

rip OPTIM

 1

0

50

Digit

rip 810

Digit

rip 910

D

igit

rip 520M

C

Digit

rip 115

0

IQ Transf

er

 II

M

P

 300

0

Digit

rip 300

0

FP 50

00

MP

CV

 Re

la

y

freq

Hz

404661

406197

1234

1834

10

x

x

x

x

x

x

x

Frequency

freq

Hz

404721

406257

1270

1870

100

x

x

x

x

x

x

x

power (real 3 ph)

W

404715

406251

126A

186A

1

x

x

x

x

x

x

x

x

x

peak demand

W

404697

406233

1258

1858

1

x

x

x

x

x

x

x

x

real 3 ph (power)

W

404651

406187

122A

182A

1

x

x

x

x

x

x

reactive 3 ph

VAR

404653

406189

122C

182C

1

x

x

x

x

x

x

apparent 3 ph

VA

404655

406191

122E

182E

1

x

x

x

x

x

A ph

W

404667

406203

123A

183A

1

x

x

B ph

W

404669

406205

123C

183C

1

x

x

C ph

W

404671

406207

123E

183E

1

x

x

reactive A ph

VAR

404673

406209

1240

1840

1

x

x

reactive B ph

VAR

404675

406211

1242

1842

1

x

x

reactive C ph

VAR

404677

406213

1244

1844

1

x

x

apparent A ph

VA

404679

406215

1246

1846

1

x

x

apparent B ph

VA

404681

406217

1248

1848

1

x

x

Power

apparent C ph

VA

404683

406219

124A

184A

1

x

x

pf (*)

pf

404717

406253

126C

186C

100

x

x

x

x

x

x

x

x

x

displacement 3 ph

pf

404657

406193

1230

1830

100

x

displacement A ph

pf

404685

406221

124C

184C

100

x

x

displacement B ph

pf

404687

406223

124E

184E

100

x

x

displacement C ph

pf

404689

406225

1250

1850

100

x

x

apparent A ph

pf

404691

406227

1252

1852

100

x

x

apparent B ph

pf

404693

406229

1254

1854

100

x

x

apparent C ph

pf

404695

406231

1256

1856

100

x

x

Power factor

apparent

pf

404659

406195

1232

1832

100

x

x

x

x

x

x

K-factor

K-factor

404663

406199

1236

1836

1

x

THD factor

THD factor

404665

406201

1238

1838

1

x

forward

KWh

N/A

406259

N/A

1872

1

x

x

x

x

x

x

x

x

reverse

KWh

N/A

406261

N/A

1874

1

x

x

x

x

x

x

total (*)

KWh

N/A

406263

N/A

1876

1

x

x

x

x

x

x

x

(K) Energy

apparent

KVAh

N/A

406271

N/A

187E

1

x

x

x

x

x

forward

Wh

N/A

406305

N/A

18A0

1

x

x

x

x

x

x

x

x

reverse

Wh

N/A

406309

N/A

18A4

1

x

x

x

x

x

x

total (*)

Wh

N/A

406313

N/A

18A8

1

x

x

x

x

x

x

x

Energy

(4 reg objects)

apparent

VAh

N/A

406329

N/A

18B8

1

x

x

x

x

x

lead

KVARh

N/A

406267

N/A

1878

1

x

x

x

x

lag

KVARh

N/A

406269

N/A

187A

1

x

x

x

x

Reactive

(K) Energy

net

KVARh

N/A

406271

N/A

187C

1

x

x

x

x

lead

VARh

N/A

406317

N/A

18AC

1

x

x

x

x

lag

VARh

N/A

406321

N/A

18B0

1

x

x

x

x

Reactive Energy

(4 reg objects)

net

VARh

N/A

406325

N/A

18B4

1

x

x

x

x

phase unbalance

%

404737

406273

1280

1880

100

x

Motor

thermal capacity

%

404739

406275

1282

1882

100

x

motor winding 1

o

C

404741

406277

1284

1884

1

x

motor winding 2

o

C

404743

406279

1286

1886

1

x

motor winding 3

o

C

404745

406281

1288

1888

1

x

motor winding 4

o

C

404747

406283

128A

188A

1

x

motor winding 5

o

C

404749

406285

128C

188C

1

x

motor winding 6

o

C

404751

406287

128E

188E

1

x

motor bearing 1

o

C

404753

406289

1290

1890

1

x

motor bearing 2

o

C

404755

406291

1292

1892

1

x

load bearing 1

o

C

404757

406293

1294

1894

1

x

load bearing 2

o

C

404759

406295

1296

1896

1

x

auxiliary

o

C

404761

406297

1298

1898

1

x

Temperature

device temperature

o

C

404763

406299

129A

189A

1

x

Table 8:  Modbus Register Map (in Functional Order), continued.

Note: All objects are 2 Registers in length unless specified otherwise.

Содержание Cutler-Hammer Modbus mMINT

Страница 1: ...ations 6 6 6 Command Data Pass Through 6 6 7 Control of INCOM Product 6 6 8 Energy Format 7 6 9 Supported Diagnostic Sub Functions 8 6 10 Exception Codes 8 7 0 Troubleshooting 9 APPENDIX A 9 Notes 19...

Страница 2: ...changes LED indicators for Modbus RS485 transmit and receive communications exchanges Input power for the module from either 120 Vac or 48 to 125 Vdc DIN rail mount package 0 C to 60 C ambient operati...

Страница 3: ...twork Make sure that there is twisted pair wire that is recommended for Modbus RTU network use Use shielded twisted pair wire to connect each slave to the Modbus RTU network daisy chain style The pola...

Страница 4: ...pproximately 1 second ON 1 second OFF However detection of a communications error on either the Modbus or INCOM network will result in an increased flashing rate approximately second ON second OFF The...

Страница 5: ...column of Table 7 or Table 8 can be established for each INCOM product attached to a mMINT Function code 16 1016 is used to load the object assignments for the block of registers The block assignments...

Страница 6: ...the configured sub network address accessed through a sub network master addressed at the INCOM main network address All INCOM Routing Address Configuration registers can be reset to their default st...

Страница 7: ...ter format is presented in units of Kwatthours and is valid for INCOM products reporting energy in watthours or Kwatthours only Products reporting in units greater than Kwatthours e g Mwatthours could...

Страница 8: ...ction exception code 07 NAK is returned If only a partial register is used in the query exception code 84 is returned Sub function No decimal Name in the query use 0 echo query mMINT or INCOM addr 1 r...

Страница 9: ...IN rail mounting 3 Control voltage is 120 VAC 20 or 48 125 VDC 4 Connectors are plug in types from Phoenix Contact 5 Terminal Types supplied with module are 3 point 4 point and 5 point Phoenix Contact...

Страница 10: ...N demand A 404649 406185 1228 1828 10 x real 3 ph power W 404651 406187 122A 182A 1 x x x x x x reactive 3 ph VAR 404653 406189 122C 182C 1 x x x x x x Power apparent 3 ph VA 404655 406191 122E 182E 1...

Страница 11: ...1892 1 x load bearing 1 o C 404757 406293 1294 1894 1 x load bearing 2 o C 404759 406295 1296 1896 1 x auxiliary o C 404761 406297 1298 1898 1 x Temperature device temperature o C 404763 406299 129A 1...

Страница 12: ...159 120E 180E 10 x x x x x x x x VBC V 404625 406161 1210 1810 10 x x x x x x x x VCA V 404627 406163 1212 1812 10 x x x x x x x x L L voltage VLLavg Vavg 404629 406165 1214 1814 10 x VAN V 404631 406...

Страница 13: ...nt B ph pf 404693 406229 1254 1854 100 x x apparent C ph pf 404695 406231 1256 1856 100 x x Power factor apparent pf 404659 406195 1232 1832 100 x x x x x x K factor K factor 404663 406199 1236 1836 1...

Страница 14: ...ed 13 Picked up 14 Phase A Trip 15 Phase B Trip 252 Product Specific Code 252 16 Phase C Trip 253 Product Specific Code 253 17 Neutral Trip 254 Product Specific Code 254 18 Ground Earth Trip 255 Produ...

Страница 15: ...lure 4 16 Over Frequency 55 Diagnostic failure 5 17 Current Unbalance 56 Diagnostic failure 6 18 Voltage Unbalance 57 Diagnostic failure 7 19 Apparent Power Factor 58 Diagnostic failure 8 20 Displacem...

Страница 16: ...ck 94 Load Bearing Temperature 136 Real Time Clock 95 Auxiliary Temperature 137 High Floating Voltage 96 Winding Temperature 138 Trip Blocked 97 Local Temperature 139 Incomplete Sequence 98 External T...

Страница 17: ...er 0 1 18 Reset min max current THD 0 1 19 Reset min max voltage THD 0 1 20 Reset min max per phase power 0 1 22 Reset op count runtime override count 0 1 36 Reset motor data maximum values 0 1 37 Res...

Страница 18: ...fer 5 0 4 Cancel ATS test 5 0 5 Go to emergency 5 0 6 Automatic Transfer Switch Control Cancel Go to emergency 5 0 7 Table 12 Control Slave Action Number Definitions continued Register10 Modbus Addres...

Страница 19: ...rchaser and Cutler Hammer Inc NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OR WARRANTIES ARISING FROM THE COURSE OF DEALING OR USAGE O...

Страница 20: ...Page 20 I L 66A7508H05 Effective September 2003 Cutler Hammer Pittsburgh PA U S A Printed in U S A...

Отзывы: