Eaton Cutler-Hammer Modbus mMINT Скачать руководство пользователя страница 12

Page 12

I.L. 66A7508H05

Effective September 2003

Objects  -  (complete list)

Register Number

Modbus Address

INCOM Products -  (partial list)

Name

numeric

Units

IEEE

float

Fixed

point

(FP)

IEEE

float

(hex)

Fixed

point

(FP)

(hex)

FP sc

ale f

act

or

IQ-

200

D

P

-4000

IQ A

n

al

yz

er

IQ Dat

a

IQ Dat

a

 P

lus I

I

Digit

rip OPTIM

 5

5

0

Digit

rip OPTIM

 7

5

0

Digit

rip OPTIM

 1

0

50

Digit

rip 810

Digit

rip 910

Di

gi

tri

p

 5

2

0

MC

Digit

rip 115

0

IQ Transf

er

 II

M

P

 300

0

Digit

rip 300

0

FP 50

00

MP

CV

 Re

la

y

Product ID

prod ID

404719 or 406255

126E or 186E

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

primary

404609  or  406145  hi  byte

1200  or  1800  hi  byte

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

secondary

404609  or  406145  lo  byte

1200  or  1800  lo  byte

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

Status
Cause

cause

404610  or  406146

1201  or  1801

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

I

A

A

404611

406147

1202

1802

10

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

I

B

A

404613

406149

1204

1804

10

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

I

C

A

404615

406151

1206

1806

10

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

I

G

A

404617

406153

1208

1808

10

x

x

x

x

x

x

x

x

x

x

x

I

N

A

404619

406155

120A

180A

10

x

x

x

x

x

x

x

x

x

x

I

Avg

A avg

404621

406157

120C

180C

10

x

x

peak I

A

 demand

A

404641

406177

1220

1820

10

x

x

peak I

B

 demand

A

404643

406179

1222

1822

10

x

x

peak I

C

 demand

A

404645

406181

1224

1824

10

x

x

peak I

G

 demand

A

404647

406183

1226

1826

10

x

Current

peak I

N

 demand

A

404649

406185

1228

1828

10

x

V

AB

V

404623

406159

120E

180E

10

x

x

x

x

x

x

x

x

V

BC

V

404625

406161

1210

1810

10

x

x

x

x

x

x

x

x

V

CA

V

404627

406163

1212

1812

10

x

x

x

x

x

x

x

x

L-L voltage

V

LLavg

Vavg

404629

406165

1214

1814

10

x

V

AN

V

404631

406167

1216

1816

10

x

x

x

x

x

x

x

V

BN

V

404633

406169

1218

1818

10

x

x

x

x

x

x

x

V

CN

V

404635

406171

121A

181A

10

x

x

x

x

x

x

x

L-N voltage

V

LN

V avg

404637

406173

121C

181C

10

x

x

N-G voltage

V

NG

V

404639

406175

121E

181E

10

x

V

AB

V

404699

406235

125A

185A

10

x

V

BC

V

404701

406237

125C

185C

10

x

V

CA

V

404703

406239

125E

185E

10

x

Source 1

freq

Hz

404705

406241

1260

1860

10

x

V

AB

V

404707

406243

1262

1862

10

x

V

BC

V

404709

406245

1264

1864

10

x

V

CA

V

404711

406247

1266

1866

10

x

Source 2

freq

Hz

4047134

406249

1268

1868

10

x

A ph

V

404801

406337

12C0

18C0

10

x

B ph

V

404803

406339

12C2

18C2

10

x

Network

voltage

C ph

V

404805

406341

12C4

18C4

10

x

A ph

V

404807

406343

12C6

18C6

10

x

B ph

V

404809

406345

12C8

18C8

10

x

Transformer

voltage

C ph

V

404811

406347

12CA

18CA

10

x

A ph

V

404813

406349

12CC

18CC

10

x

B ph

V

404815

406351

12CE

18CE

10

x

C ph

V

404817

406353

12D0

18D0

10

x

A ph direct

V

404819

406355

12D2

18D2

10

x

A ph quadrature

V

404821

406357

12D4

18D4

10

x

B ph direct

V

404823

406359

12D6

18D6

10

x

B ph quadrature

V

404825

406361

12D8

18D8

10

x

C ph direct

V

404827

406363

12DA

18DA

10

x

C ph quadrature

V

404829

406365

12DC

18DC

10

x

pos seq direct

V

404831

406367

12DE

18DE

10

x

Phasing

voltage

pos seq quadrature

V

404833

406369

12E0

18E0

10

x

Table 8:  Modbus Register Map (in Functional Order)

Note: All objects are 2 Registers in length unless specified otherwise.

Содержание Cutler-Hammer Modbus mMINT

Страница 1: ...ations 6 6 6 Command Data Pass Through 6 6 7 Control of INCOM Product 6 6 8 Energy Format 7 6 9 Supported Diagnostic Sub Functions 8 6 10 Exception Codes 8 7 0 Troubleshooting 9 APPENDIX A 9 Notes 19...

Страница 2: ...changes LED indicators for Modbus RS485 transmit and receive communications exchanges Input power for the module from either 120 Vac or 48 to 125 Vdc DIN rail mount package 0 C to 60 C ambient operati...

Страница 3: ...twork Make sure that there is twisted pair wire that is recommended for Modbus RTU network use Use shielded twisted pair wire to connect each slave to the Modbus RTU network daisy chain style The pola...

Страница 4: ...pproximately 1 second ON 1 second OFF However detection of a communications error on either the Modbus or INCOM network will result in an increased flashing rate approximately second ON second OFF The...

Страница 5: ...column of Table 7 or Table 8 can be established for each INCOM product attached to a mMINT Function code 16 1016 is used to load the object assignments for the block of registers The block assignments...

Страница 6: ...the configured sub network address accessed through a sub network master addressed at the INCOM main network address All INCOM Routing Address Configuration registers can be reset to their default st...

Страница 7: ...ter format is presented in units of Kwatthours and is valid for INCOM products reporting energy in watthours or Kwatthours only Products reporting in units greater than Kwatthours e g Mwatthours could...

Страница 8: ...ction exception code 07 NAK is returned If only a partial register is used in the query exception code 84 is returned Sub function No decimal Name in the query use 0 echo query mMINT or INCOM addr 1 r...

Страница 9: ...IN rail mounting 3 Control voltage is 120 VAC 20 or 48 125 VDC 4 Connectors are plug in types from Phoenix Contact 5 Terminal Types supplied with module are 3 point 4 point and 5 point Phoenix Contact...

Страница 10: ...N demand A 404649 406185 1228 1828 10 x real 3 ph power W 404651 406187 122A 182A 1 x x x x x x reactive 3 ph VAR 404653 406189 122C 182C 1 x x x x x x Power apparent 3 ph VA 404655 406191 122E 182E 1...

Страница 11: ...1892 1 x load bearing 1 o C 404757 406293 1294 1894 1 x load bearing 2 o C 404759 406295 1296 1896 1 x auxiliary o C 404761 406297 1298 1898 1 x Temperature device temperature o C 404763 406299 129A 1...

Страница 12: ...159 120E 180E 10 x x x x x x x x VBC V 404625 406161 1210 1810 10 x x x x x x x x VCA V 404627 406163 1212 1812 10 x x x x x x x x L L voltage VLLavg Vavg 404629 406165 1214 1814 10 x VAN V 404631 406...

Страница 13: ...nt B ph pf 404693 406229 1254 1854 100 x x apparent C ph pf 404695 406231 1256 1856 100 x x Power factor apparent pf 404659 406195 1232 1832 100 x x x x x x K factor K factor 404663 406199 1236 1836 1...

Страница 14: ...ed 13 Picked up 14 Phase A Trip 15 Phase B Trip 252 Product Specific Code 252 16 Phase C Trip 253 Product Specific Code 253 17 Neutral Trip 254 Product Specific Code 254 18 Ground Earth Trip 255 Produ...

Страница 15: ...lure 4 16 Over Frequency 55 Diagnostic failure 5 17 Current Unbalance 56 Diagnostic failure 6 18 Voltage Unbalance 57 Diagnostic failure 7 19 Apparent Power Factor 58 Diagnostic failure 8 20 Displacem...

Страница 16: ...ck 94 Load Bearing Temperature 136 Real Time Clock 95 Auxiliary Temperature 137 High Floating Voltage 96 Winding Temperature 138 Trip Blocked 97 Local Temperature 139 Incomplete Sequence 98 External T...

Страница 17: ...er 0 1 18 Reset min max current THD 0 1 19 Reset min max voltage THD 0 1 20 Reset min max per phase power 0 1 22 Reset op count runtime override count 0 1 36 Reset motor data maximum values 0 1 37 Res...

Страница 18: ...fer 5 0 4 Cancel ATS test 5 0 5 Go to emergency 5 0 6 Automatic Transfer Switch Control Cancel Go to emergency 5 0 7 Table 12 Control Slave Action Number Definitions continued Register10 Modbus Addres...

Страница 19: ...rchaser and Cutler Hammer Inc NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY OR WARRANTIES ARISING FROM THE COURSE OF DEALING OR USAGE O...

Страница 20: ...Page 20 I L 66A7508H05 Effective September 2003 Cutler Hammer Pittsburgh PA U S A Printed in U S A...