Contents
Description
Page
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
1 General Description - Digitrip RMS 510
Trip Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
1 .1 Basic Digitrip RMS 510 Trip Unit . . . . . . . . . . . . . . . . . . . . . . .3
1 .1 .1 Operational Status and Protection TRIP Indicators . . . . . .4
1 .1 .2 General Over-Current Protection . . . . . . . . . . . . . . . . . . . .5
1 .1 .3 Discriminator (High Initial Current Release)
(For Types LS and LSG Trip Units Only) . . . . . . . . . . . . . . .7
1 .1 .4 OVERRIDE (Fixed Instantaneous) . . . . . . . . . . . . . . . . . . .7
1 .1 .5 Zone Interlocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
1 .2 Frame Rating, Sensor Rating (where applicable) and Rating
Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
1 .3 Auxiliary Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
2 UL Listed Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3 Protection Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 .1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 .2 Long Delay Current Setting . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 .3 Long Delay Time Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 .4 Short Delay Current Setting . . . . . . . . . . . . . . . . . . . . . . . . . 10
3 .5 Short Delay Time Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3 .6 Instantaneous Current Setting . . . . . . . . . . . . . . . . . . . . . . . 11
3 .7 No Instantaneous Current Setting . . . . . . . . . . . . . . . . . . . . 11
3 .8 Ground Fault Current Setting . . . . . . . . . . . . . . . . . . . . . . . . 11
3 .9 Ground Fault Time Delay Setting . . . . . . . . . . . . . . . . . . . . .12
4 Test Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4 .1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4 .2 When To Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4 .3 Testing Provisions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
4 .4 Conducting Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4 .4 .1 Control Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
4 .4 .2 Not Tripping the Breaker . . . . . . . . . . . . . . . . . . . . . . . . .13
4 .4 .3 Tripping the Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
4 .5 Testing the Back-up Battery (Inside the Rating Plug) . . . . . .14
4 .5 .1 Back-up Battery Check . . . . . . . . . . . . . . . . . . . . . . . . . .14
4 .5 .2 Replacing the Back-up Battery . . . . . . . . . . . . . . . . . . . .14
5 References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
5 .1 Digitrip RMS Trip Assemblies . . . . . . . . . . . . . . . . . . . . . . . .15
5 .2 Type DS Low-Voltage AC Power Circuit Breakers . . . . . . . . .15
5 .3 Type DS II Low-Voltage AC Power Circuit Breakers . . . . . . .15
5 .4 Type SPB Systems Pow-R . . . . . . . . . . . . . . . . . . . . . . . . . . .15
5 .5 Series C
®
R-Frame Molded Case Circuit Breakers . . . . . . . .15
APPENDIX A: Zone lnterlocking . . . . . . . . . . . . . . . . . . . . . . . . . . .16
List of Figures
Description
Page
Figure 1 . RMS Digitrip 510 Trip Unit - Block Diagram . . . . . . . . . . . . . 3
Figure 2 . Digitrip RMS 510 Trip Unit Type LSIG with Rating Plug . . . . 4
Figure 3 . Digitrip RMS 510 Type Ll . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 4 . Digitrip RMS 510 Type LS . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Figure 5 . Digitrip RMS 510 Type LSI . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 6 . Digitrip RMS 510 Type LIG . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 7 . Digitrip RMS 510 Type LSG . . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 8 . Digitrip RMS 510 Type LSIG . . . . . . . . . . . . . . . . . . . . . . . . 6
Figure 9 . Rating Plug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Figure 10 . Auxiliary Power Module . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Figure 11 . Long Delay Current Settings . . . . . . . . . . . . . . . . . . . . . . .10
Figure 12 . Long Delay Time Settings . . . . . . . . . . . . . . . . . . . . . . . . .10
Figure 13 . Long Time Memory "LTM" Jumper . . . . . . . . . . . . . . . . . .10
Figure 14 . Short Delay Current Settings . . . . . . . . . . . . . . . . . . . . . . .10
Figure 15 . Short Delay Time Settings . . . . . . . . . . . . . . . . . . . . . . . . .11
Figure 16 Instantaneous Current Settings . . . . . . . . . . . . . . . . . . . . .11
Figure 17 . Ground Fault Current Settings . . . . . . . . . . . . . . . . . . . . . .11
Figure 18 . Ground Fault Time Delay Settings . . . . . . . . . . . . . . . . . . .12
Figure 19 . Integral Test Panel (Lower Right Corner of Trip Unit) . . . . .13
Figure A .1 Typical Zone Interlocking (Ground Fault Protection) . . . . .16
Figure A .2 Typical Zone Interlocking Connections with Two Main
Breakers (M1, M2) and a Tie Breaker (T) (Short Delay
Protection) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
List of Tables
Description
Page
Table 1 . Ground Fault Current Settings . . . . . . . . . . . . . . . . . . . . . . 11