DRAFT - 07 March 2016
DRAFT - 07 March 2016
INM MTL GECMA WS display rev 2
5
3 .2 Provisions for general operational safety
3 .3 Application
The MTL GECMA 19, 22 and 24 WS display modules are individually certified and
designed for industrial use in the potentially explosive atmospheres of Zone 1 and
Zone 2.
The corresponding certificates are:
19” Sira 14 ATEX5063X
IECEx SIR 14.0032X
22” Sira 14 ATEX5063X
IECEx SIR 14.0032X
24” Sira 14 ATEX5063X
IECEx SIR 14.0032X
The products are marked:
19” Ex mb ib IIC T4 Gb Ta = -30°C to +60°C
22” Ex mb ib IIC T4 Gb Ta = -30°C to +60°C
24” Ex mb ib IIC T4 Gb Ta = -30°C to +60°C
3 .4 Safety guidelines
These safety guidelines contain information and precautions that must be taken into
account for safe operation in the conditions described.
The Safety Provisions chapter must be studied carefully and adhered to.
The Operating Instructions must be read before installing or using the terminal.
We do not accept liability for printing errors and mistakes in these operating instructions.
Should you have any queries or questions please do not hesitate to contact us.
3 .5 ATEX safety Instructions
The following information is in accordance with the Essential Health and Safety
Requirements (Annex II) of the EU Directive 2014/34/EU [the ATEX Directive
- safety of apparatus] and is provided for those locations where the ATEX
Directive is applicable.
General
a. This equipment must only be installed, operated and maintained by competent
personnel. Such personnel shall have undergone training, which included
instruction on the various types of protection and installation practices,
the relevant rules and regulations, and on the general principles of area
classification. Appropriate refresher training shall be given on a regular basis.
[See clause 4.2 of EN 60079-17].
b. This equipment has been designed to provide protection against all the relevant
additional hazards referred to in Annex II of the directive, such as those in
clause
1.2.7.
c. This equipment has been designed to meet the requirements of EN 60079-0,
EN 60079-11 and EN 60079-18.
continued on the next page