manualshive.com logo in svg
background image

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY

The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation’s 

(“Eaton”) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales 

office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in 

appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser.
THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES 

OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY 

EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE 

CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. 
In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or 

other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to 

damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of 

existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, 

recommendations and descriptions contained herein. The information contained in this manual is subject to change without 

notice. 

ii

COMPANION II BACK-UP CURRENT-LIMITING FUSE INSTALLATION INSTRUCTIONS

  MN132009EN   

Содержание Companion II back-up current-limiting fuse

Страница 1: ...Companion II back up current limiting fuse installation instructions COOPER POWER SERIES Fusing Equipment MN132009EN Effective December 2015 Supersedes S240 64 1 December 2013...

Страница 2: ...ANY EXISTING CONTRACT BETWEEN THE PARTIES ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES In n...

Страница 3: ...ial inspection 1 Handling and storage 1 Quality standards 1 APPLICATION Fuse application 2 INSTALLATION PROCEDURE Installation of the Companion II fuse 2 Installation of terminal options 4 RE FUSING R...

Страница 4: ...Life mission Safety information DANGER Hazardous voltage Contact with hazardous voltage will cause death or severe personal injury Follow all locally approved safety procedures when working around hi...

Страница 5: ...actory It is in good condition when accepted by the carrier for shipment Upon receipt of the Companion II fuse inspect the connector thoroughly for damage and loss of parts incurred during shipment If...

Страница 6: ...of Terminal Options on page 4 1 Remove fuseholder from distribution cutout using a hookstick Always use a loadbreak device to open an energized cutout Follow manufacturer s recommendations for operati...

Страница 7: ...irect expulsion gases towards the Companion II fuse Apply minimal cantilever load to the Companion II fuse 5 Re energize the line using approved safety procedures Figure 4 Companion II fuse mounted fr...

Страница 8: ...ECT ARRESTER CUTOUT FUSE LINK IN FUSE HOLDER TRANSFORMER PRIMARY BUSHING Figure 6 Completely Self Protected CSP transformer mounted Companion II fuse without separate distribution cutout ARRESTER COMP...

Страница 9: ...5 ft lbs Figure 10 Spline stud terminal Terminal code G 1 Insert threaded end of the spline stud into the tapped center hole of the Companion II fuse and torque spline stud to 10 15 ft lbs Figure 11 O...

Страница 10: ...split lock washer onto the bolt and insert the bolt through the connector hole into the tapped center hole of the fuse and torque the bolt to 10 15 ft lbs Figure 15 3 Assemble carriage bolt parallel...

Страница 11: ...fuse should always be tested after an operation of the fuse cutout 1 Perform a continuity check on the Companion II fuse 2 If the Companion II fuse does have continuity go to the Installation Procedu...

Страница 12: ...nformation call 1 877 277 4636 or visit www eaton com cooperpowerseries Eaton 1000 Eaton Boulevard Cleveland OH 44122 United States Eaton com Eaton s Cooper Power Systems Division 2300 Badger Drive Wa...

Отзывы: