background image

Eaton

Cooper Sécurité SAS

PEE II - Rue Beethoven - BP10184 

63204 RIOM CEDEX FRANCE

Tél. +33 (0)825 826 212  

(0,15  € TTC/min)

www.cooperfrance.com

www.eaton.eu

© 2015 Eaton

ZNO1031100 B - 09/2015

Tous droits réservés.

All Rights Reserved.

Eaton est une marque déposée.

Eaton is a registered trademark.

Toutes les autres marques 

appartiennent à leurs propriétaires 

respectifs. 

All trademarks are property  

of their respective owners.

Smoke Alarm

09/2015

NUG35941

Installation and Operating Manual 

ZNO1031100 B

This self-contained smoke alarm is suitable for:

• 

individual houses and flats;

• 

camper-vans and caravans.

WARNING 

NOT SUITABLE FOR BOATS. 

Read this manual carefully before use and keep it for any 

future use.

1.  Mounting

Do not paint the smoke alarm.
The device should be ceiling-mounted, in a place where it is easy to access 

to facilitate tests and cleansing. 
The smoke alarm must be placed at min. 50 cm 

from closest wall and at max. 10 m from other 

alarm, preferably in the middle of the ceiling. 

Location 

• 

Minimum one alarm between poten-

tial sources of fire and bedrooms.

• 

One optional alarm on each floor, in 

corridors and staircases. 

• 

One optional alarm in each living area, 

bedrooms, living-room - dining room, 

storerooms. 

Do not place 

any smoke alarm:

• 

in dusty rooms;

• 

on top of a steep roof or in a blind angle;

• 

in rooms where temperature can go either below +4ºC or above +38ºC;

• 

in rooms where non-condensing relative humidity can be more than 

90%;

• 

in kitchens, garages, rooms with fireplaces where humidity and smoke 

are frequent.  

Smoke alarm mounting 

1.  Unclip the alarm from its base turning 

counterclockwise

2.  Use the base to mark fixing holes with a pencil 

on the ceiling. Then fix the base to the 

ceiling using provided screws and wall 

plugs.

3.  After installation, press Test button to 

test the alarm. The device will make a 

high pitched and loud sound.

IMPORTANT : Do not remove product 

internal label. It shows important 

information relative to the device.

2.  Operation

Normal mode

LED flashing approximately every 48 seconds without sound.

Alarm mode

LED fl high pitched loud discontinuous sound every second.

Low battery

Short sound + LED flashing every 48 seconds.  

Alarm to be replaced within 30 days. 

Hush Function

In case of false alarm, press Hush button while the alarm is on to cut it off. 

Alarm mode will come back after about 10 minutes.

3.  Test

Test the smoke alarm at first use, once a month and after every battery 

replacement pressing Test button.

• 

Operation OK: Short high pitched and loud sound + LED flash.

4.  Technical features

Alarm

Lithium battery (included)

Type

Photoelectric non-radioactive Not replaceable 

Signal

Repeated high pitched 

sounds (in case of fire) 

IMPORTANT

DO NOT REPLACE THE BATTERY. 

REPLACE THE PRODUCT IF THE 

BATTERY FAILS.

Level

Min. 85 dB at 3 m

5.  Maintenance 

Monthly clean-up: dusting with vacuum cleaner and optional wiping with a 

wet cloth.  
Do not open the alarm.

 

Problem

Cause

Solution

False alarm

Dust particles in the 

chamber filter

or

High condensing humidity

Heavily blow on the mesh 

or vacuum with a vacuum 

cleaner.

Dry the alarm.

No sound when Test 

button is pressed

Battery is probably low.

Replace the alarm.

Replace the smoke alarm every 10 years or if alarm is 

damaged.

 

6.  Recycling

Battery and smoke alarm need a specific treatment. Follow local 

regulations and laws relative to recycling. 

7.  Essential certified characteristics covered by the NF

Type of mounting

Ceiling only

Main power supply

Internal power supply

Battery duration

10 years

Interconnectable device 

No

Suitable for installation in camper-vans

Yes

Connection to external auxiliary devices

No

Radio link

No

Individual alarm indicator 

Yes

Alarm silence facility (10 minutes)

Yes

Non-radioactive infrared technology

Yes

Accessibility Option

No

Sound

Chamber 
filter
Test/Hush 
button / LED

Mounting 
base

10 year Smoke Alarm diameter 4cm

D4-S10

bathroom

optional alarms

minimum alarms

bedroom

bedroom

corridor

living-room

basement

kitchen

bedroom

50 cm min.

Ceiling

Wall

General warranty terms

COOPER SÉCURITÉ SAS (Groupe EATON) warranties these products for a 1-year period (date of 
manufacture as proof), under the general terms set out below.
• 

Full warranty on parts and workmanship.

• 

Any defective luminaires shall be returned carriage paid to

COOPER SÉCURITÉ SAS (Groupe EATON) Parc Européen d’Entreprises II, Rue Beethoven, BP 10184, 
63204 RIOM Cedex, FRANCE.
Self-contained luminaires replaced or repaired under the terms of this warranty shall be shipped back 
carriage paid.
The warranty is void:
• 

if the material has been transformed, modified or repaired outside of COOPER SÉCURITÉ SAS 
(Groupe EATON) workshops;

• 

if the defectiveness is due to misuse or inappropriate connection.

The CE marking on this product is securing the conformity to the European directives that are applicable 
and in conformity to the harmonised specification of EN 14604.
NF – DOMESTIC FIRE SAFETY brand is testing the conformity of this product to the certification NF 292.

DAAF

PA

R

 A

FN

OR

 CE

RTIF

ICATION

www.marque-nf.com

15

0333

EN14604 : 2005 + AC : 2008

Dop No. 2002-011

0333-CPR-292058-12

AFNOR Certification - 11 rue Francis de Pressensé 

FR - 93571 LA PLAINE SAINT DENIS Cedex FRANCE

Отзывы: