8
Installation manual 10679
Effective October 2017
BSPA Type 1 and Type 2 surge protective devices
Eaton.com/bussmannseries
9. Specifications
kA per phase
50, 100, 150, 200
Nominal discharge current
20 kA
Single-phase voltages
120, 240
Split-phase voltages
120/240
Wye system voltages
120/208, 240/415, 277/480, 347/600
Delta system voltages
240, 480, 600
Input power frequency
50/60 Hz
Protection modes
Single-phase L-N, N-G, L-G
Split-phase
L-N, N-G, L-G, L-L
Wye
L-N, N-G, L-G, L-L
Delta
L-G, L-L
Mounting feet torque rating
20.3 lb-in (2.3 N•m)
Conduit locknut torque rating
Not to exceed 200 lb-in (22.5 N•m)
Operating temperature
-40°F to +140°F (-40°C to +60°C)
Relative humidity
5% - 95%, non condensing
Max. altitude
2000 m
Weight, vary per configuration
P1 enclosure ~2.5 lbs
P2 enclosure ~4.0 lbs
Agency information
UL 1449 4
th
Edition, UL1283 6
th
Edition, CSA 269.1-14, 269.2-15,
C22.2 No. 8-13 EMI filter
SPD type
UL 1449 4
th
Edition and CSA Type 1
and Type 2 SPD
RoHS compliant
Yes
Enclosure rating
NEMA 4X, IP65 with mounting feet
10. Maintenance
The BSPA is a self-contained device that requires no maintenance
and contains no serviceable parts. If any LED turns red or yellow,
the unit has lost surge protection and must be replaced. Please
contact your local authorized Bussmann series product distributor or
Bussmann series product representative, as the BSPA may be under
warranty.
11. Liability
This instruction manual is published solely for information purposes
and should not be considered all-inclusive. If further information is
required, you should consult Application Engineering 7:00 a.m. —
5:00 p.m. Central time, Monday-Friday or email FuseTech@eaton.
com. Sale of the product shown in this manual is subject to terms
and conditions outlined in appropriate Bussmann Division selling
policies or other contractual agreements between the parties. This
manual is not intended to and does not enlarge or add to any such
contract. The sole source governing the rights and remedies of any
purchaser of this equipment is the contract between the purchaser
and the Bussmann Division.
NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR
MERCHANTABILITY, OR WARRANTIES ARISING FROM COURSE
OF DEALING OR USAGE OF TRADE, ARE MADE REGARDING
THE INFORMATION, RECOMMENDATIONS AND DESCRIPTIONS
CONTAINED HEREIN.
In no event will the Bussmann Division be responsible to the
purchaser or user in contract, in tort (including negligence),
strict liability or otherwise for any special, indirect, incidental or
consequential damage or loss whatsoever, including but not
limited to damage or loss of equipment use, plant or power
system, cost of capital, loss of power, additional expenses in the
use of existing power facilities or claims against the purchaser or
user by its customers resulting from the use of the information,
recommendations and description contained herein.
12. Catalog number system
The catalog numbering system permits specifying any combination
to meet requirements.
BSPA 200 208Y 8 P
BSPA = Product family
Surge rating per phase
•
050 = 50 kA per phase
•
100 = 100 kA per phase
•
150 = 150 kA per phase
•
200 = 200 kA per phase
Voltage/system code
•
120N = 120 V single-phase (2W +G)
•
240N = 240 V single-phase (2W +G)
•
240S = 120/240 V split-phase (3W +G)
•
240D = 240 V Delta (3W + G)
•
480D = 480 V Delta (3W + G)
•
600D = 600 V Delta (3W + G)
•
208Y = 120/208 V Wye (4W + G)
•
415Y = 240/415 V Wye (4W + G)
•
480Y = 277/480 V Wye (4W + G)
•
600Y = 347/600 V Wye (4W + G)
Options
•
1 = No options (standard configuration), Type 1
•
4 = Form C relay, Type 1
•
5 = Audible alarm and Form C relay, Type 1
•
7 = EMI filtering and Form C relay, Type 2
•
8 = EMI filtering, audible alarm and Form C relay, Type 2
NEMA enclosure
•
P = NEMA 4X