WCB 11060 (PDF Format)
6
© Copyright Eaton Corp., 1998. All rights reserved
June, 1998
Figure 5
NOTE: The coolant outlets should be positioned at the 12 o-clock position.
Table 1
Item
Desciption
Item
Description
1
Mounting Flange Sub-assembly
24
Warning Decal
3
Wear Plate
25
Name Plate
6
Stud
26
Screw
7
Friction Disc Sub-assembly
28
Gear
8
Friction Disc
29
Wear Spacer
9
Friction Disc Core
30
Reaction Plate Sub-assembly
12
Clamp Tube
32
Decal Plate
13
Pressure Plate Sub-assembly
33
Piston
17
Flat Washer
34
Release Spring
18
Locknut
47
Wear Ring
19
Cylinder
57
Flat Head Screw
21
Polypak Seal
59
Stop Tube
Table 2
Tensioner Mounting Register Diameters - In. (mm)
Size
Female Register
Male Register
18WCB
18.250/18.253 (463.5/463.6)
23.250/23.247 (590.5/590.4)
24WCB
24.375/24.378 (619.1/619.2)
29.998/29.995 (761.9/761.8)
36WCB
18.375/18.378 (466.7/466.8)
44.498/44.493 (1130.2/1130.1)
Registers to be .125"-.188"(3.2-4.8mm) deep.