Table 4-4: Option Board A2 Terminal Descriptions
Figure 4-5: Option Board A2 Terminal Locations
Inverting the Digital Input Signal
The active signal level depends on which potential the common inputs CMA and CMB
(terminals 11 and 17) are connected to. The alternatives are 24V or ground (0V). See
Figure 4-6.
The 24V control voltage and the ground for the digital inputs and the common inputs (CMA,
CMB) can be sourced from either the internal 24V supply or an external supply.
Figure 4-6: Positive/Negative Logic
Positive logic (+24V is the active signal) = the input is active when the switch is closed.
Negative logic (0V is the active signal) = the input is active when the switch is closed.
Terminal
Signal
Technical Information
21
RO1/1
Normally Closed (NC)
Switching Capacity:
24V DC / 8A
250V AC / 8A
125V DC / 0.4A
Min Switching Load: 5V/10 mA
Continuous Capacity: <2 Arms
22
RO1/2
Common
23
RO1/3
Normally Open (NO)
24
RO2/1
Normally Closed (NC)
Switching Capacity:
24V DC / 8A
250V AC / 8A
125V DC / 0.4A
Min Switching Load: 5V/10 mA
Continuous Capacity: <2 Arms
25
RO2/2
Common
26
RO2/3
Normally Open (NO)
21
22
23
24
25
26
DIN1
+24V
DIN2
DIN3
CMA
Ground
DIN1
Ground
DIN2
DIN3
CMA
+24V
1
2