background image

IOM  Controls 

04/2020

 

REV B. 

Page 9 of 9 

Eaton  Filtration  LLC,  44 Apple Street, Tinton  Falls, NJ 07724    www.eaton.com/filtration    Phone: 732-212-4700 

 

 

Installation, Operation & Maintenance Manual 

Control Panels for Automatic Self-Cleaning Strainers 

Model 596 and Model 2596

 

 

TYPICAL INSTALLATION

 

 

 
 
 

 
 
 

 
 
 

 
 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 
 
 
 
 
 

 
 
 
 

 
 

 

 

 

North America

 

44 Apple Street  
Tinton Falls, NJ 07724 

Toll Free: 800 656-3344 
(North America only) 

Tel: +1 732 212-4700 

 
 
Europe/Africa/Middle East

 

Auf der Heide 2 
53947 Nettersheim, Germany 

Tel: +49 2486 809-0 

Friedensstraße 41 
68804 Altlußheim, Germany 

Tel: +49 6205 2094-0 

An den Nahewiesen 24 
55450 Langenlonsheim, Germany 

Tel: +49 6704 204-0 

China

 

No. 3, Lane 280, 
Linhong Road  
Changning District, 200335  
Shanghai, P.R. China 

Tel: +86 21 5200-0099 

 
 
Singapore

 

100G Pasir Panjang Road #07-08 
Singapore 118523 

Tel: +65 6825-1668 

 
 
Brazil

 

Av. Ermano Marchetti, 1435 - 
Água Branca, São Paulo - SP, 
05038-001, Brazil  

Tel: +55 11 3616-8461 

For more information, please  
email us at 

[email protected]  

or visit

 www.eaton.com/filtration 

© 2020 Eaton. All rights reserved. All trademarks and 
registered trademarks are the property of their respective 
owners. All information and recommendations appearing in 
this brochure concerning the use of products described 
herein are based on tests believed to be reliable. However, 
it is the user’s responsibility to determine the suitability for 
his own use of such products. Since the actual use by 
others is beyond our control, no guarantee, expressed or 
implied, is made by Eaton as to the effects of such use or 
the results to be obtained. Eaton assumes no liability 
arising out of the use by others of such products. Nor is the 
information herein to be construed as absolutely complete, 
since additional information may be necessary or desirable 
when particular or exceptional conditions or circumstances 
exist or because of applicable laws or government 
regulations. 

US 

04-2020 

 

Содержание 2596

Страница 1: ... Timed Cycle 2 Valves 2 Valve Selection 2 Backwash Blow Down Drain Valve 3 Electric Actuators 3 Pneumatic Actuators 3 Differential Pressure Switches 4 Switch Description 4 Mounting Piping and Wiring 4 Adjustment 4 Control Panel 5 Description 5 Cycle Time Sequence 5 Standard Features 5 Operating Modes 6 Changing Backwash Timer Settings 6 SmartWire DT Error Messages 7 System Error Messages 7 Electri...

Страница 2: ...d protection and fused disconnect STRAINER MODE OF OPERATION AUTOMATIC BACKWASH TIMED CYCLE The preferred mode of operation for a self cleaning strainer is one where the control system will permit both intermittent and continuous backwash as required by operating conditions The drain line requires a blow down drain valve which may be manually operated Normal valve position is CLOSED The backwash l...

Страница 3: ...PNEUMATIC ACTUATORS A double acting piston design that uses a clean air supply of 40 125 psi pressure powers the actuator properly Using an electric signal a solenoid pilot valve controls the air supply to the actuator Most actuators have pipe thread connections NPT located so that the solenoid valves may be mounted with minimal tubing runs Customer must run wiring and conduit from the control pan...

Страница 4: ...ure connections furnished on the inlet discharge nozzles of the strainer as shown in Fig 1 Customer must supply and run wiring and conduit between the differential pressure switch and the control panel See Fig 2 for wiring connections DIFFERENTIAL SWITCH ADJUSTMENT While it is possible to use other equipment than what is described below any installation should have the items described here Equipme...

Страница 5: ... supply The ACS line of control panels allows operation either in the Manual or Auto modes In the Manual mode the strainer will continuously backwash In the Auto mode the strainer is allowed to backwash according to the preset timing cycle or when the differential pressure switch is activated NOTE The customer determines the timing cycle length and changes it as required The control logic protects...

Страница 6: ... closes then HIGH DIFFERENTIAL indicator illuminated HI DP alarm contact closes AUTO MODE Timer range limits for BACKWASH ON valve open is 1 to 1440 minutes Timer range limits for BACKWASH OFF valve closed is 1 to 1440 minutes CHANGING THE BACKWASH TIMER SETTINGS To change timer settings press ALT button Use the UP or DOWN arrow buttons to move the cursor to select lines BW Open SP or BW Close SP ...

Страница 7: ...errors If a hardware error occurs the screen will display what device and node is damaged or disconnected If more than one node is damaged or disconnected the screen will cycle though all errors present SYSTEM ERROR MESSAGES Motor Overload If there is a motor overload the following message will flash on the screen Hi DP Backwash Hi DP backwash is indicated by the red LED and with a change of state...

Страница 8: ...ge 8 of 9 Eaton Filtration LLC 44Apple Street Tinton Falls NJ 07724 www eaton com filtration Phone 732 212 4700 Installation Operation Maintenance Manual Control Panels for Automatic Self Cleaning Strainers Model 596 and Model 2596 ...

Страница 9: ...ranca São Paulo SP 05038 001 Brazil Tel 55 11 3616 8461 For more information please email us at filtration eaton com or visit www eaton com filtration 2020 Eaton All rights reserved All trademarks and registered trademarks are the property of their respective owners All information and recommendations appearing in this brochure concerning the use of products described herein are based on tests bel...

Отзывы: