TRANSPORTATION AND STORAGE
The furnace can be transported by any means of transportation as long as conditions mentioned on
the marking are observed.
The furnace should be stored indoors in the original packaging.
TROUBLESHOOTING GUIDE
In case if any malfunctioning has been detected, you should immediately stop exploiting the
furnace and contact our specialists to get a troubleshooting assistance on a possible cause of
this failure and remedial procedures to fix it.
Abnormality in the
combustion process
Smell of smoke
It is di cult to light up the
furnace
Water doesn't get to the
steam generating unit
The safety valve doesn't work
Outgoing vapor has a
specific smell
When hot-water system is
running, walls of water
receiving tank start to inflate
Water in the system boils
Water in the heat-exchange
unit boils, but water in the
water receiving tank is still
cold
Air deficiency in the heater
Di culty of a chimney draft
Di culty of a chimney draft
Insu cient leak-tightness of the
chimney
Chimneys
'
deterioration
Draft
di culty
Back-pressure valve is clogged
Foreign object in the back-
pressure valve
Poor-quality stones
Old stones
Dysfunction of the steam removing
system
Water level is below the minimum
Clogging of inlet pipes
Incorrect installation
1
2
1
2
3
1
2
1
2
Clean the ash box
Clean the chimney
Clean the chimney
Check and seal up
chimneys' joints
Replace the chimney
Clean the chimney
Take o and unclog the
dispensing funnel
Take o and unclog the
dispensing funnel
Replace stones and
clean the heater
Replace stones and
clean the heater
Clean the system
Add some water or drain
the system
Unclog inlet pipes
Consult a manufacturer
2
Failure
Cause of a failure
Remedial procedure
1
2
1
3
2
1
2
1
34