A-44
Appendix
Interface : Host Bus Duall Loop 2Gb Fibre channel
Disk Bus Ultra ATA-1100 * 16
Drives Hot Swap, User Replaceable
Up to 16 x 3.5” drives (1” Height)
Maximum Fault >3.5 TB
Tolerant Capacity
Drive MTBF >1,000,000 hrs
Host Requirement Host Independent
Operating Systems O/S Independent and Transparent
Data Rebuild Automatic Data Regeneration
LCD Display Panel 2 x 16 Characters
Cooling Fans 12cm Ball Bearing Fan
2 Fans
Power Supply Capacity 300W * 3 (2 +1) Independent
Power Supplies
AC Input Voltage 100V ~ 240V ( +/10% ) , 63/47 Hz
Environmental
Relative Humidity 0% to 85% Non-c
condensing
Temperature Operating : 5c~ 40c
Storage : -225c~ 60c
Safety testing UL, CE and FCC Class B
Dimensions 175mm(H) * 483mm(W) * 583mm(D)
Weight 23 kgs ( W/O Disk Drive )
“ * “ Default Settings
*** Various trademarks belong to their respective owners.
Technical Specfication X16P F2R4
Содержание X12P F2R4
Страница 60: ...4 8 8 Advanced Information Step 2 ...
Страница 61: ...4 9 9 Advanced Information Step 3 Enter a name for your Terminal ...
Страница 62: ...4 1 10 Advanced Information Step 4 Select a connecting port in your Terminal ...
Страница 63: ...4 1 11 Advanced Information Step 5 Port parameter setting ...
Страница 64: ...4 1 12 Advanced Information Step 6 ...
Страница 67: ...4 1 15 Advanced Information 2 Press Y to download the new firmware and press Y again to confirm the Update ...
Страница 68: ...4 1 16 Advanced Information 3 Select transfer Send Text File and press Enter ...
Страница 69: ...4 1 17 Advanced Information 4 Locate the new Firmware file on your PC ...
Страница 70: ...4 1 18 Advanced Information 5 Press Go to confirm to download the new firmware ...
Страница 104: ...5 3 3 Hot Swap b Gently pull o out the HDD tray ...
Страница 105: ...5 4 4 Hot Swap c Unscrew and unplug the cables Figure Swap HDD Unplug cables ...