DISPLAY STATUS INDICATION

• 

On startup, the LCD runs through a test sequence in which all elements are activated, the alarm LEDs light up and the sounder beeps.

• 

The CO

2

 sensor may take a few minutes to self-calibrate after startup, before readings are given. During this time keep in fresh air.

The high-contrast LCD shows current, 

maximum and minimum readings, as 
well as alarm and logger status:

Battery level

Minimum Reading

Maximum Reading

Calibration reminder

WiFi signal strength

Warning notification

CO

2

 alarm status

Temperature alarm status

Temperature  reading

Temperature units

CO

2

 reading

CO

2

 units

Humidity alarm status

Humidity reading

Humidity units

Display

Logger Status

Explanation

Startup

The logger is starting 

up, the number 

displayed is the 

firmware version

Not configured

The logger has not 

yet been connected 

to the EasyLog Cloud, 

readings will be 

displayed but not 

uploaded

Setup Mode

The device is in setup 

mode, ready to connect 

to the EasyLog Cloud

Connected to App

The device has 

connected to the 

EasyLog App as part 

of the setup process

Setup Fail

The device has been 

unable to complete the 

setup process, check 

the availability of 

your WiFi network 

and try again

Firmware Update 

The device is loading 

new firmware (you can 

check for updates on 

the EasyLog Cloud)

Display

Logger Status

Explanation

Update Failed

The device has failed 

to load new firmware 

and will automatically 

revert to the previous 

version

CO

2

 Calibration 

Due

You should activate 

the CO

2

 Fresh Air 

Calibration process

CO

2

 Fresh Air 

Calibration

The device is 

recalibrating the CO

2

 

sensor, leave it exposed 

to fresh air during this 

process

CO

2

 Calibration 

Failed

The device was unable 

to calibrate the CO

2

 

sensor, you should 

expose it to fresh air 

and try again

Device warning

Press MIN/MAX to 

cycle through readings 

screens to see warning 

screens

Alarm light and mute button

Содержание EL-IOT-CO2

Страница 1: ...nimum readings for carbon dioxide temperature and humidity as well as alarm and device status The EL IOT CO2 runs from a USB power supply supplied with the product and can use AA batteries to provide...

Страница 2: ...both system and data events Starter and Professional accounts are available always flexible and with no locked in contracts If you choose not to connect your EL IOT CO2 to the Cloud it will still meas...

Страница 3: ...on Not configured The logger has not yet been connected to the EasyLog Cloud readings will be displayed but not uploaded Setup Mode The device is in setup mode ready to connect to the EasyLog Cloud Co...

Страница 4: ...initiate data synchronisation with the Cloud Long Press Enter Setup mode Short Press Reset all active alarms they will immediately re trigger if an alarm threshold is breached Long Press Enter CO2 Fre...

Страница 5: ...300 000 readings Dimensions 97 x 87 x 33mm Operating Temperature Battery Power 18 to 55 C 0 to 131 F USB Power 20 to 60 C 4 to 140 F Environmental Rating IP4X CO2 FRESHAIR CALIBRATION To maintain the...

Страница 6: ...n ambient conditions the response time of the humidity sensor in your data logger is approximately 20 minutes to reach 90 of the reading However if you are measuring step changes in humidity for examp...

Страница 7: ...all Fixing Screws 3 5 x 20mm countersunk head cross recessed stainless steel BATTERYINFORMATION This device is designed to be powered using the USB power supply provided The logger does not lose its s...

Отзывы: