background image

www.lascarelectronics.com

Issue 1   06/2022

EL-IOT-CO2

Carbon Dioxide WiFi Cloud-Connected Data Logger

Your data, anytime, anywhere

BUTTON FUNCTIONS

Button

Press

Function

TOP BUTTON

-

Mute alarm sounder (it will 

re-activate when a new 

alarm is activated)

Short Press

Cycle between current, 

minimum and maximum 

readings, and any warning 

screens

Long Press

Reset the maximum and 

minimum values for all 

parameters

Short Press

Create an audit mark in the 

data record and initiate 

data synchronisation with 

the Cloud

Long Press

Enter Setup mode

Short Press

Reset all active alarms 

(they will immediately 

re-trigger if an alarm 

threshold is breached)

Long Press

Enter CO

2

 Fresh Air 

Calibration mode

1

3

Connect the power 
supply and the device 
will turn itself on.

You can now view the EL-IOT-CO2’s data 
and change settings either in the EasyLog 
Cloud App or by visiting your account at: 

www.easylogcloud.com

CONNECTING TO THE CLOUD

2

Download and login to 
the EasyLog Cloud App 
on your mobile device. 
Select “Setup Device” 
and follow the on-
screen instructions to 
add your EL-IOT-CO2.

MIN / MAX

CLEAR M/M

AUDIT

CONFIG

RESET ALARM

CALIBRATION

Содержание EL-IOT-CO2

Страница 1: ...nimum readings for carbon dioxide temperature and humidity as well as alarm and device status The EL IOT CO2 runs from a USB power supply supplied with the product and can use AA batteries to provide...

Страница 2: ...both system and data events Starter and Professional accounts are available always flexible and with no locked in contracts If you choose not to connect your EL IOT CO2 to the Cloud it will still meas...

Страница 3: ...on Not configured The logger has not yet been connected to the EasyLog Cloud readings will be displayed but not uploaded Setup Mode The device is in setup mode ready to connect to the EasyLog Cloud Co...

Страница 4: ...initiate data synchronisation with the Cloud Long Press Enter Setup mode Short Press Reset all active alarms they will immediately re trigger if an alarm threshold is breached Long Press Enter CO2 Fre...

Страница 5: ...300 000 readings Dimensions 97 x 87 x 33mm Operating Temperature Battery Power 18 to 55 C 0 to 131 F USB Power 20 to 60 C 4 to 140 F Environmental Rating IP4X CO2 FRESHAIR CALIBRATION To maintain the...

Страница 6: ...n ambient conditions the response time of the humidity sensor in your data logger is approximately 20 minutes to reach 90 of the reading However if you are measuring step changes in humidity for examp...

Страница 7: ...all Fixing Screws 3 5 x 20mm countersunk head cross recessed stainless steel BATTERYINFORMATION This device is designed to be powered using the USB power supply provided The logger does not lose its s...

Отзывы: