RM-208 CB.13.01 Easy Line Documentation  

RDN 10000795 

2

 

20.03.2019 

Table of Contents 

1  Safety instructions ..................................................................................................................................... 3

 

2  Equipment specification ............................................................................................................................. 3

 

3  Assembly ................................................................................................................................................... 4

 

4  “Step by step” installation........................................................................................................................... 5

 

5  “Step by step” settings ............................................................................................................................... 7

 

5.1  Function when shipped ................................................................................................................... 7

 

5.2  Setting parameters .......................................................................................................................... 7

 

5.3  Parameter list .................................................................................................................................. 9

 

6  Operating modes ..................................................................................................................................... 10

 

6.1  Test mode ..................................................................................................................................... 10

 

6.2  Down time cleaning ....................................................................................................................... 10

 

6.3  Cleaning via start / stop input (external 

p switch) ....................................................................... 10

 

7  Troubleshooting ....................................................................................................................................... 11

 

7.1  Instructions for the replacement of the device fuse ...................................................................... 11

 

7.2  Cleaning the controller .................................................................................................................. 12

 

7.3  Manufacturing ............................................................................................................................... 12

 

8  Text messages on the display ................................................................................................................. 13

 

9  Details on the equipment function ........................................................................................................... 14

 

10  Glossary ................................................................................................................................................. 15

 

11  Technical specifications ......................................................................................................................... 16

 

 

 

 

Regulations 

 
2014/30/EU 

 

2014/35/EU 

 

 

 

 

Legends 

 

 

Warning against physical and health hazards or damages to the product and other properties. 

 

 

 

Attention, make absolutely sure to observe the notes in the documentation! 

 

 

 

Important note 

 

 

 

 

 

 

Identification of safety class II (protective insulation). 

Complete double insulation or reinforced insulation. 

The symbol is affixed to the device. 

 

 

Identification of direct current (DC). 

Содержание RM-208 CB.13.01

Страница 1: ...Operating and Installation Instructions Filter control system RM 208 CB 13 01 EasyLine Supply voltage 110 V AC...

Страница 2: ...structions for the replacement of the device fuse 11 7 2 Cleaning the controller 12 7 3 Manufacturing 12 8 Text messages on the display 13 9 Details on the equipment function 14 10 Glossary 15 11 Tech...

Страница 3: ...cable laws conditions orders and regulations governing the setting up of electrical equipment must be observed with respect to the installation site Setting of equipment with degree of protection IP00...

Страница 4: ...RM 208 CB 13 01 Easy Line Documentation RDN 10000795 4 20 03 2019 3 Assembly Wall mounting of the filter controls is not permitted The device may only be mounted to machine parts...

Страница 5: ...RM 208 CB 13 01 Easy Line Documentation RDN 10000795 5 20 03 2019 4 Step by step installation Supply voltage connection Solenoid valve connection Connection of expansion modules RM LV8 RM LV16...

Страница 6: ...accessible for the user and to be marked as disconnecting device for the equipment The wires and cables used for the connection of the controls must be suitable for an ambient temperature of up to 13...

Страница 7: ...ameters P02 P11 in sequence The parameters already displayed can be accessed by repeatedly pressing the button To change the value of a displayed parameter press the ENTER button for at least one seco...

Страница 8: ...RM 208 CB 13 01 Easy Line Documentation RDN 10000795 8 20 03 2019...

Страница 9: ...ve test 2 Input test 3 5 For manufacturer purposes only Off 0 0 5 P09 P09 Ser run hour Service operating hours P10 P10 Ser run h AL Service operating hours alarm 0 h 0 25000 h P11 P11 Ser r h Code Ser...

Страница 10: ...e down time cleaning perform the following steps Remove the factory fitted wire jumper on input 10 11 Connect a free auxiliary contact make contact of the fan contactor to terminals 10 and 11 The inpu...

Страница 11: ...the fan control Activate signal to input 10 11 Cleaning ineffective Interval time too long Set parameter P02 Interval to a lower value Pressure too low Set pressure to 6 8 bar min 5 bar Set parameter...

Страница 12: ...part of the housing and tighten the six screws evenly Switch on the supply voltage again 7 2 Cleaning the controller Wipe only with a damp cloth if outside of device is soiled 7 3 Manufacturing The f...

Страница 13: ...abled via input 10 11 and stopped via input 12 13 Cleaning Off Val No The control has been enabled via input 10 11 and started via input 12 13 Cleaning On Val No Down time cleaning active DTC Cleaning...

Страница 14: ...Relay output 8 9 to control extractor elements If automatic components for dust removal extractor elements are fitted these need to be in operation during cleaning and during down time cleaning Connec...

Страница 15: ...r element contactor Contactor which switches an extractor element drive unit on and off I O module Input output module module for the input and output of control signals Operation mode Status of the R...

Страница 16: ...ell 5MT 300 mA ESKA UL 521 012 Temperature range 20 C to 50 C Protection class Housing IP 66 not evaluated by UL Type 5 Installation torque of cover screws 1 5 Nm Weight approx 0 8 kg Installation hei...