background image

Figure 9

 - Ignition Gap

TROUBLE SHOOTING

WARNING: Service and repair should only be
accomplished by a gas appliance technician or your
gas company.

Problem

 - Main burner(s) will not light.

Solution 

- Check gas shut-off valve is “ON.”  Depending

on the gas line length, it may require further “bleeding” to
remove trapped air.  If no gas is heard escaping the
burner, remove the burner and venturi assembly. 
Carefully unscrew the burner orifice located at the end of
the gas valve.  Inspect the orifice for blockage from
particles in the gas piping system (Do not clean the
orifice by forcing something through the metering hole).

Problem

 - Ignitor will not spark.

Solution

 - Push ignitor button and watch for sparking

between the electrode and ignitor box for the EC30 or
match light carryover for the EC24.  If no sparks are
visible, replace battery by unscrewing the button top.
Additionally check the wire connections at the electrode
and ignitor.  Test again and if no sparks are noted at any
electrodes, replace ignitor.  If sparking at only one
electrode is noted, check electrode for clean grounding. 
Check spark gaps between all electrodes.  The gap
should be approximately 1/4" 

(figure 9)

.

Problem

 - Low flame and/or low heat output.

Solution

 - Check the gas supply shut-off valve.  Make

sure it is fully open.  If the gas supply is an LPG tank,
check the gas quantity.  Check pressure of gas supply
down stream from gas regulator.  Make sure it meets
minimum requirements on rating label located on front of
the grill.

MAINTENANCE

Cleaning and maintenance should be performed at least
annually on your grill.  The following check list will help:

1) Remove grids and stainless ceramic baffles. 

Remove all loose materials from burners and
cabinet.  
Brush area around igniter carefully removing grease
and residue.  
Inspect burners for damaged areas.  
Replace burners if there are any areas that appear
burnt through.  
Replace components per assembly instructions.

2) Check gas supply lines, regulator, and valves for

signs of wear or distress.  
Replace any items that show any signs of cracking or
burning.

3) Rotisserie burner units require the screen to be

cleaned.  Carefully brush loose materials and
residue from the screen.

General cleaning may be accomplished by using a
household cleaning solution and warm water.  The
exterior may be cleaned using the same method.  Badly
soiled areas can be clean using a “scotch brite” pad. 
Always scrub in same direction of material finish.

With proper care your 

EasyChef

 grill will give you years

of trouble free service.  If you have any questions
regarding this product please contact  - Customer
Service, Sierra Products, Inc., Monday thru Friday
8:00am to 4:00pm PST at (775) 241-2586.

For warranty qualification and coverage information,
see enclosed limited warranty sheet.

9

Содержание EC24

Страница 1: ...the vicinity of this or any other appliance 2 An LP tank not connected for use shall not be stored in the vicinity of this or any other appliance WARNING Do not try to light this appliance without rea...

Страница 2: ...e EasyChef has a range of installation options available They include built in cart pedestal and permanent post With some fore thought and planning the EasyChef can be installed with minimum effort Re...

Страница 3: ...r leave your EasyChef barbecue under an unprotected combustible roof or overhang i Your EasyChef is not intended for installation in or on a recreational vehicle or boat i Do not use combustible mater...

Страница 4: ...ves figure 6 If any components have moved or are not aligned loosen the 2 10 nuts securing the burners and re align These nuts may be accessed from underneath the grill If your model includes the roti...

Страница 5: ...y CART PEDESTAL POST ASSEMBLIES The EasyChef Grill may be assembled on one of the following mountings available from your local dealer DESCRIPTION EC24 P N EC30 P N Deluxe Cart 10655 10565 Pedestal Ca...

Страница 6: ...hutter setting of 1 4 for natural gas and 5 8 for LPG gas 5 Check the ignitor cables are snugly connected to the ignitor terminals 6 Follow the LIGHTING instructions on the following pages 7 Once the...

Страница 7: ...tion and wait 5 minutes to let the gas clear before trying again or trying to light with a match ROTIS BURNER Never operate main and rotis burners at the same time with the hood closed The rotis burne...

Страница 8: ...ourses at one time is possible The key to accomplishing this is timing Things like potatoes require 30 minutes at low with fish fillets or lobster requiring 10 minutes or less Consider outdoor conditi...

Страница 9: ...If the gas supply is an LPG tank check the gas quantity Check pressure of gas supply down stream from gas regulator Make sure it meets minimum requirements on rating label located on front of the gri...

Страница 10: ...1006 6a 1 Rotis Front Panel Graphic 140272 22 1 Rotis Motor 110197 7 3 Control Knob 110185 23 2 Prong Forks 110191 8 2 Electrode 120061 24 1 Spit Rod 110246 9 2 Electrode Wire 120063 25 1 Spit Rod Bea...

Страница 11: ...1 Rotis Motor 110197 7 3 Control Knob 110185 23 2 Prong Forks 110191 8 2 Electrode 120061 24 1 Spit Rod 110189 9 2 Electrode Wire 120063 25 1 Spit Rod Bearing 110192 10 2 Control Valve Nat 44 120059...