background image

                                            

INSTALLATION

 

The  plasma cutter is equipped  with power voltage compensation equipment. When 

power voltage fluctuation between

±

15%

 of rated voltage, it still can work normally. 

 

When  the machine is used  with  long cables, in order to prevent voltage 

from

  going 

down, bigger section cable is suggested. If cable is too long, it may affect the performance 

of the power system. So we suggest you use cables of configured length.. 

1.Make sure the intake of the machine not blocked or covered to avoid the malfunction of 

system. 

2.Use cable (section not less than 6mm

)

 to connect the housing and the ground. The way is 

  from the connecting screw in the back of the power source, or make sure ground firmly. 

  For absolute safety, both ways can be used. 

3.Use pressure-resisting air pipe to connect the air intake and compressed air source, and 

  use hoop and other way to tighten the joint. Air source should supply suitable pressure, 

    flow and be dry. If your air source does not meet the above requirements, you 

    should consider using sole compressor of the right power and air-decompressing filter, in 

    order to supply suitable pressure and eliminate the impurity and moisture in the air.   

4.Install the air-electricity system plug to the socket in the panel and fix it clockwise. Air 

plug of the cutting torch and arc-keeping cable(forCUT80/100/160) should be connected 

to relevant socket, and fix the screw.                       

5.Put the loop cable plug to the fastening socket,   

and tighten clockwise, another terminal holds the   

work piece. 

6.According to input voltage grade, connect   

  power cable with power supply box of relevant 

  voltage grade. Make sure there is no mistake 

  and make sure the voltage is different among   

permission range. 

7.Connect the cable as the picture shows. 

You can start cutting. 

 

CUT80/100/160  INSTALLATION  

 

 

Содержание VERSA CUT60

Страница 1: ...USER S MANUAL MODEL...

Страница 2: ...to avoid breathing gas Arc radiation harmful to your eyes and burn your skin Use suitable helmet and light filter wear protective garment to protect eyes and body Use suitable helmet or curtain to pro...

Страница 3: ...a arc It has the functions of arc initiation current arc stop current welding current basic value current current ascending time current descending time gas delay time continuous adjustment What s mor...

Страница 4: ...utput voltage V 104 112 120 144 Duty cycle 60 60 60 60 Efficiency 85 85 85 85 Power factor 0 93 0 93 0 93 0 93 Insulation grade F F F F Housing Protection grade IP21 IP21 IP21 IP21 Arcing Way Untouche...

Страница 5: ...e and compressed air source and use hoop and other way to tighten the joint Air source should supply suitable pressure flow and be dry If your air source does not meet the above requirements you shoul...

Страница 6: ...Make sure power voltage is inside the waved range Output cable connection 1 Make sure tube of pressed air is connected to copper connector by high pressure rubber tube firmly 2 Make sure copper screw...

Страница 7: ...osition 4 Get down the plastic screw and fix the regulator on the shelf 5 Turn on the air valve turn up the pressure adjusting knob Turn the pressure to rated volume meter inside shows KG and then put...

Страница 8: ...Press the control knob of torch electromagnetic valve is starting sound of HF arc striking can be heard and burner of torch should flow out gas Burner of arc supporting cutter should spurt fire 4 It i...

Страница 9: ...result current and air pressure must be matched well So when the current is set the pressure and flow must be adjusted suitably If the air flow is too big and cooling effect is too strong it will caus...

Страница 10: ...of environment User should make sure the working area is adequately ventilated It is important for the performance and the longevity of the machine 2 Do not over load The operator should remember to...

Страница 11: ...ow and input cable is too long C Output current is not up to the rated value When power voltage departs from the rated value it will make the output current not matched with rated value When voltage i...

Страница 12: ...d steam enter into inter machine if they enter into machine please dry inter machine then check insulation of machine 5 If welding machine will not be operated long time it must be put into packing bo...

Страница 13: ...ken or switch broken 3 Control circuit is broken Contact factory Abnormal indicator is lit Meter is normal Fan is normal 1 High pressure device is broken 2 IGBT is broken 3 Rectifier broken 4 Control...