14 Installation
For units equipped with a takeaway conveyor at the exit of the L-sealer, provision
should be made for exiting packages. For example, a table or bin where packages that
have been sealed will be placed until they can be picked up, or a conveyor that will
move them to the tunnel.
If the L-sealer is part of a longer packaging line, take into consideration the table and
conveyor height in relation to adjacent machinery.
The machine should be placed on a flat, level floor so that it does not rock or move. We
recommend that the machine be securely locked in place when used.
Set up the L-sealer and move it to its location. The casters allow easy movement over
smooth flat surfaces. If you need to lift the unit to move it, you will need to use a pallet
jack, floor crane, or fork lift to move it to its location.
CAUTION!
If the L-sealer must be lifted for moving, use proper
equipment when lifting and moving it to ensure it is secure
and will not shift.
When the L-sealer has been moved to its location, use the levers on the casters to lock
the wheels to prevent rolling and keep the unit in place. A power cord (with optional
electrical plug) should be installed by a licensed electrician.
CAUTION!
Before operating, ensure the following.
1. All shipping ties are removed.
2. All personnel are clear of the equipment.
3. Electrician has stated that all electrical work is complete.
4. Adjust all controls according to the settings sheet.
Refer to instructions in the Operation section for instructions to power up or shut down
the machine.