29
6. Disassembly and replacement of the main PCB
Tips
:
The main PCB is of great importance in the control part of a massage chair. Controlled by the
microcomputer, the external equipment of the computer system is more stable than the control circuit. So when
one part is non-functional, first we should check the voltage is supplied by the main PCB or not. Reasoning
should be applied and check all the parts concerning the failure, then you may find out the reason for the failure.
As a matter of fact, you should find the problem of the chair, then repair it. It is inconsiderable to replace all the
parts concerned when on part fails, although it will have the job done. But lots of manpower and material
resources will be wasted. You should learn the principle of the chair, then will find the reason more quickly.
①
Pull out the power cord connector, release the stopper at the bottom of back rest, turn down the back rest
forward.
②
Slacken and remove the screws, 6 pieces, fixing the rear cover under the seat. And you can take out the rear
cover.
③
Bear in mind the connection of the teminals to avoid confusion.Then pull them out.
④
Disconnet the PCB supporter locking the main PCB on the base plate with a nipper pliers, then the PCB can
be taken off.
⑤
Proceed in the reverse order of disassembly when replacing a new one.
PCB supporter
Screws fixing the cover
Terminals on the main PCB