13
8.1 Application 1
The application examples given below are for illustration only.
8 TYPICAL APPLICATIONS
3
5
6
7
8
11.1
4
4.2
4.1
10
13
13
17
18
11.2
11
11.3
FHL1
FHL2
FHLn
19
20
Outdoor
Indoor
1
4.4
4.3
6.1
9
AHS
13
Code
Assembly unit
Code
Assembly unit
1
Main unit
11
Domestic hot water tank (Field supply)
2
11.1
TBH: Domestic hot water tank booster
heater (Field supply)
3
SV1:3-way valve (Field supply)
11.2
Coil 1, heat exchanger for heat pump
11.3
Coil 2, heat exchanger for Solar energy
4.1
Automatic air purge valve
12
Filter (Accessory)
4.2
Drainage valve
13
Check valve (Field supply)
4.3
Tbt1:
Balance
tank upper temperature
sensor (Optional)
14
Shut-off valve (Field supply)
4.4
Tbt2:
Balance
tank lower temperature
sensor (Optional)
15
Filling valve (Field supply)
5
P_o: Outside circulation pump (Field supply) 16
Drainage valve (Field supply)
6
P_s: Solar pump (Field supply)
17
Tap water inlet pipe (Field supply))
6.1
Tsolar: Solar temperature sensor (Optional) 18
Hot water tap (Field supply)
6.2
Solar panel (Field supply)
19
Collector/distributor (Field supply)
7
P_d: DHW pipe pump (Field supply)
20
Bypass valve (Field supply)
8
T5: Domestic water tank temperature
sensor (Accessory)
FHL
1…n
Floor heating loop (Field supply)
9
T1: Water flow temperature sensor
(Optional)
AHS
Auxiliary heat source (Field supply)
16
2
Modbus
15
16
14
12
14
User interface
4
Balance tank (Field supply)
10
Expansion vessel (Field supply)
6.2
V.1