MAINTENANCE 

 

PAGE 15 

BURN RECOMMENDED FUEL

 

This appliance is approved for use with natural dry wood 
only. Burning materials other than natural wood will shorten 
the life of the catalytic combustor. Do not burn particleboard 
or pressed logs using bonding agents as they can produce 
conditions which will deteriorate metal or damage the cata-
lyst. Green or uncured wood does not work well as fuel, 
and can cause increased creosote buildups and plugging 
of the catalytic combustor. The value of green wood as a 
source of heat is limited. Do not overload or use kindling 
wood or mill ends for primary fuel as this may cause overfir-
ing. Overfiring is a condition where excessive temperatures 
are reached, beyond the design capabilities of the fireplace 
insert. The damage that occurs from overfiring is not cov-
ered under the fireplace insert warranty. 
 

WHY SEASON WOOD? 

The key to the success of a good fire that produces heat 
from a wood burning insert is the wood. It needs to be well-
seasoned natural wood. 
 
What does “Well-Seasoned” mean? 
 
When a tree is cut down, the wood is green, full of sap and 
moisture. This moisture content can exceed 80%, which 
must be reduced to less than 20%. Wood properly sea-
soned is then capable of generating the heat the fireplace 
insert was designed to provide. 
 
Green wood does not burn easily. Attempting to burn green 
wood often results in a lot of smoke and very little fire. Time 
is the most important factor in seasoning wood.  Ideally the 
moisture content should be reduced to 11-20%, although 
very few of us will be able to check that figure.  There are 
several steps that should be taken to ensure that that you 
come close to these figures. 
 

SEASONING GUIDE 

Softwoods – 6 months to 18 months 
Hardwoods – 12 months to 24 months 
 
Logs that are 5” diameter across or larger should be split in 
half, three pieces if over 8 inches, and four pieces when 
over a foot across.  If the tree was fell 2 to 4 years ago, it 
still needs to be cut, split, and seasoned for 6 to 24 months 
depending on the wood. 

 
WOOD STORAGE 

Wood to be seasoned should be stacked in an area open 
enough to ensure good air circulation on both sides – leav-
ing adequate space between woodpiles to walk comfort-
able.  Do not stack wood against a wall or building.  It helps 
to elevate the woodpiles off the ground (two 2 x 4’s running 
lengthwise beneath the woodpile works well). This allows 
air to flow under the bottom logs. 
 

Wood that is kept outdoors, either covered with a tarp, or 
not covered at all, will not burn well until it has been in an 
enclose space for one to two months.  

 
SMALL AREA PAINT TOUCH-UP

 

The stove body is painted with a quality high-
temperature stove paint. Use only model TSPK-B Stove 
Paint, Catalog # 70K99. Do not touch-up your stove with 
any other paint. 
 
Using one small piece of 320 grit sand paper and lightly 
sand the blemish so that the edges are “feathered” or 
smooth to the touch between the painted and bare sur-
faces. Do not let the sand paper gum up with paint, as 
this will cause scratches on the metal surface. If there 
are any scratches, use 600 grit sandpaper instead. Mask 
off surfaces you do not want painted. Paint lightly over 
the bare surface first as this will act as an undercoat. 
Then paint over a larger area in smooth even strokes to 
blend.  

 
See Break-In Period on page 13 for information on 
curing the paint.

 

 

FIREBRICK

 

The firebrick should be inspected periodically and re-
placed if damaged (crumbling or excessively cracked). 
 

ASH REMOVAL AND DISPOSAL

 

 

CAUTION: Make sure that the fire is out and the 
stove is cold before removing ashes! (If optional ash 
drawer is installed) Never burn your stove with the 
ash dump cover off! 

 
Ashes can hold live embers for several days, and must 
be disposed of with care.  
 
(If the optional ash drawer is installed) Scrape ashes 
from the firebox through ash dump opening into ash 
drawer. After emptying, clean and replace the ash 
drawer. 
 
NEVER place ashes in a cardboard box or any other 
combustible receptacle.  
 

Proper Disposal of Ashes: 

Ashes should be placed in a metal container with a tight 
fitting lid. The closed container of ashes should be 
placed on a noncombustible floor or on the ground, well 
away from all combustible materials, pending final dis-
posal. If the ashes are disposed of by burial in soil or 
other wise locally dispersed, they should be retained in 
the closed container until all cinders have thoroughly 
cooled. 

 

Содержание BV400C-2

Страница 1: ...EL BV400C 2 RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE EPA CERTIFIED CATALYTIC WOOD BURNING FIREPLACE INSERT THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER READ ENTIRE MANUAL THOROUGHLY BEFORE INSTALLATION P N 775 005M Rev M 12 03 ...

Страница 2: ...imney con nector glows you are overfiring Overfiring this appliance could cause a house fire Overfiring is a condition where the appliance is operated at temperatures above its design capabilities see Overfiring on page 19 Overfiring can be caused by improper installation improper op eration lack of maintenance or improper fuel usage Damage caused from overfiring is NOT covered under the manufactu...

Страница 3: ...re probe and sleeve One Damper hook One Skid plate One 48 x 32 Surround Kit USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention to the safety instructions provided in this manual The Home owner s Care and Operation Instructions included here will assure you have many years of dependable and enjoyable service from your applian...

Страница 4: ...hin the same room you must follow the requirements of your local code Check with your local building de partment for requirements in your area IMPORTANT THIS APPLIANCE IS NOT APPROVED FOR INSTALLATION INTO A MANUFACTURED MO BILE HOME FLOOR PROTECTION This appliance requires a heat resistant non combustible approved fireplace hearth or hearth extension If a hearth extension is used it must be a 3 8...

Страница 5: ...tute ANSI NFPA 211 92 draft 1 7 A chimney or vent shall be so designed and con structed to develop a flow sufficient to completely remove all flue and vent gases to the outside atmosphere The venting system shall satisfy the draft requirements of the connected appliance in accordance with the manufacturer s instructions PROVIDE ADEQUATE AIR FOR COMBUSTION In well insulated and weather tight homes ...

Страница 6: ...S This appliance is approved for installation into a ma sonry fireplace built to UBC Chapter 37 standards Do not remove brick or mortar form the masonry fireplace to accommodate this appliance Venting Requirements for masonry fireplace The fireplace damper must be secured in the open po sition As a minimum a flue extension past the fireplace header is required A preferred installation is a positiv...

Страница 7: ... your Catalytic Combus tor should operate between 1000 1800 F POWER CORD CHANGEOVER DANGER Risk of electrical shock Disconnect power be fore servicing unit Do not route power cord beneath heater To change the power cord from one side of insert to the other perform the following steps 1 Ensure power cord in NOT plugged in 2 Remove the louver blower panels on each side of fuel door as follows Each p...

Страница 8: ...starter pipe with flue See Offset Adapter page 24 for ordering information Do not push in sert in completely until surround assembly is in stalled Care should be used to ensure that this ad justable connector is oriented so it does not angle downhill when positioned on the flue outlet on top of insert Offset Adaptors comes in two sizes See page 24 11 The floor of the fireplace is lower then the he...

Страница 9: ...ing il lustrations Attach trim to the surround Clips Heat Deflector Must Be Installed If There is a Mantel 16 Push the insert back until surround panel insulation is compressed against the fireplace front forming a tight seal Test for air leaks by holding a candle around the edge of the surround to see if the smoke is pulled into the fireplace TEST FOR AIR LEAKS BY HOLDING A CANDLE AROUND EDGE OF ...

Страница 10: ...stall 6 or 8 flex pipe to achieve the same result Use an offset adapter see page 24 to handle offsets This part is available through your dealer A preferable installation is the positive flue connection a posi tive seal between the flue extension and the chimney This can be achieved by using a filler plate A filler plate can be made by making a cardboard pattern to fit the fireplace throat Lay the...

Страница 11: ...ower Higher AIR AND DAMPER CONTROLS CATALYTIC BYPASS DAMPER CONTROL The bypass damper control handle is located on the front of the insert see above illustration By pushing in or pulling out the handle the operator can route the ex haust either through the catalytic combustor pushed in or directly up the flue pulled out When starting a fire or refueling the handle must be pulled out Once the fire ...

Страница 12: ...will help clean off much of the normal buildup see Troubleshooting A commer cial glass cleaner designed for fireplace inserts is rec ommended for cleaning The glass should be cleaned thoroughly with glass cleaner and a soft cloth BEFORE the fireplace insert is burned DOOR GASKET The door gasket must be kept in good condition Do not leave the stove burning with the door ajar or open Leav ing the do...

Страница 13: ...ueling we recommend that the stove be refired for about 10 minutes with the bypass open to ensure a good draw is established and that the catalyst reaches 600 F The refiring will ensure sufficient tempera tures and proper amounts of volatiles for the catalyst to operate properly When refueling a hot stove with the catalyst still operating no refiring step is necessary Just open the bypass set the ...

Страница 14: ... have to be manually turned off by rotating the rheostat dial counterclockwise until it clicks CAUTION Burning the insert at a high burn rate for extended periods without running the blowers can cause excessive temperatures resulting in overfir ing damage to the appliance Overfiring damage is not covered under the 5 year prorated warranty WARNING This appliance is equipped with a blower system whi...

Страница 15: ...h to ensure good air circulation on both sides leav ing adequate space between woodpiles to walk comfort able Do not stack wood against a wall or building It helps to elevate the woodpiles off the ground two 2 x 4 s running lengthwise beneath the woodpile works well This allows air to flow under the bottom logs Wood that is kept outdoors either covered with a tarp or not covered at all will not bu...

Страница 16: ...his creosote makes an extremely hot fire Also creosote deposits tend to form in long runs of venting where gases become too cool prior to exhausting Note Single wall pipe cools rapidly there fore installations using this type of flue are more suscep tible to creosote deposits To inhibit the build up of creosote adjust the primary air control to a medium high or high setting for a 10 minute period ...

Страница 17: ...r old combustor can be improved by following this Major Cleaning Procedure Soak the combustor in a hot cleaning solution of a 50 50 mixture of white vinegar and distilled water for 30 minutes Then rinse by soak ing in hot distilled water After 15 minutes remove the combustor from the rinse water and gently shake out excess water It is unlikely that you will notice a visible difference in the combu...

Страница 18: ...e based on average climates and home design 5 There s an obstruction in the chimney 6 The chimney or chimney cap is restricted by creosote preventing enough draw to sustain a HIGH heat rate 7 Combustor light off has not occurred DOES NOT MAINTAIN A FIRE 1 Soft wood does not burn as long or as well as seasoned hardwood resulting in a short burn time 2 Wood size too small Burns at too rapid a rate 3...

Страница 19: ...ft requirements of the appliance are being met A draft gauge should read between 05 and 07 inches water column W C I Excessive draft above 07 W C I will allow too much combustion air to be pulled into the firebox which results in hotter burns Too little draft below 05 W C I will not allow enough combustion air delivery to maintain a fire well or cause performance problems such as smoking this may ...

Страница 20: ...Stove to Center of Flue 6 Approximate burn time 8 12 hours Approximate Fuel capacity 80 lbs Firebox size cubic feet 3 72 c f Maximum Burn Rate BTU 66 805 EPA BTU Range 11 000 48 100 BTU EPA Efficiency 72 Emissions Rate grams hour 3 0 gph Approximate weight with brick 455 lbs Air Control Manual Blower Assemblies Standard 500 cfm Comes standard with 4 blowers 125 cfm each heat activation switch manu...

Страница 21: ...g BV100 Probe Combustor Temperature 11485 Housing Combustor 11481H Gasket Interam Combustor 1 16 x3 x36 Room Air Blower Parts 410 25L Blower Assembly Left 410 25R Blower Assembly Right 11565 Disc Low Limit fan disc for blowers F110 20F 60T12 LB 102280 Wire Harness Kit Includes Left Side Crossover Wire Harness Right Side Wire Harness and Power Cord 10050087 Knob Rheostat LB 101496 Motor Blower 1 ea...

Страница 22: ...ed FB22 Firebrick 9 x 3 Regular order 2 if set is needed FB 1 Firebrick 9 x 4 Regular order 8 if set is needed FB 2 Firebrick 9 x 4 w Notch order 4 if set is needed 11812 Gasket Ash Dump 4 1 4 x 8 3 8 x 1 2 C 200 51 Hook Damper Coil handle with hook for opening closing damper bypass Blower assemblies include 2 blowers w propellers mounting bracket and terminal block All firebrick are 1 thick FIREB...

Страница 23: ... Shown HANDLE ASSEMBLY P N LB 102214 DRAFT MODULE ASSEMBLY Cat No 26M68 WIRE HARNESS KIT P N LB 102280 Includes the following 3 Components Wire Harness Right Side Wire Harness Left Side Crossover Wires To Left Side Replacement Power Cord Damper Rod Damper Stop LB 102215 Set Screws Damper Door Damper Blade Assembly Torque Plate Nut Washers Handle Rod Coil Handle ...

Страница 24: ...ic Black 12 oz Spray Can stove pipe paint OFFSET ADAPTERS CAT NO 14M77 8 to 8 for Masonry Fireplaces 14M79 8 to 6 for Factory Built Fireplaces Installations requiring offsets can be handled using an offset adapter it aligns starter pipe with flue CAT NO 14M77 8 to 8 CAT NO 14M79 8 to 6 Actual Appearance OPTIONAL ASH DRAWER Catalog 14M69 The optional ash drawer assembly installs underneath the ap p...

Страница 25: ...SAFETY LISTING LABEL PAGE 25 ...

Страница 26: ...EPA LABEL PAGE 26 ...

Страница 27: ...ERSHIP RECORDS PAGE 27 Dealer s Name Dealer s Address City State Zip Code Serial Number Date of Purchase Date Installed Notes SERVICE AND MAINTENANCE LOG Service Service Service Date Technician Description ...

Страница 28: ...1110 West Taft Avenue Orange CA 92865 ...

Отзывы: