23
Summary
WARNING:
Never use gasoline, gasoline type lantern fuel,
kerosene, charcoal lighter fluid or other similar liquids to start
or “freshen up” the fire in this fireplace or in any fireplace.
WARNING:
If processed solid fuel firelogs are used: Do not poke
or stir the logs while they are burning. Use only firelogs that
have been evaluated for the application in fireplace and refer
to firelog warnings and caution markings on packaging prior to
use.
5. Avoid over-firing this fireplace. Some examples of over-
firing are:
a. Burning of scrap lumber, construction debris, pine branches
and brush or cardboard boxes;
b. Burning small diameter twigs, branches or any other small
sized combustible materials in quantities which exceed the
volume of the normal log fire;
c. Use of artificial wax base logs, trash or other chemicals or
chemically treated combustibles.
WARNING:
Over-firing can permanently damage this
fireplace system.
6. Fireplace Doors and Screens:
This fireplace has not been tested for use with doors.
To reduce the risk of fire or injury, do not install doors. If doors
are required by the local authority having jurisdiction then
doors must be kept in the fully open position when the fireplace
is in operation. Isokern does not limit the use of fireplace
screens.
7.
Disposal of Ashes:
It is recommended that the firebox be cleaned of
excessive ashes before each use. It is necessary to remove
ashes from the open front of the fireplace. To do so, proceed in
the following manner:
Allow the fire to go out and the ashes to cool for at
least six to eight hours.
After the cooling period carefully pick up the ashes
from the firebox with a small, metal fireplace shovel or other
metal scoop and place them in a metal container with a tight
fitting lid.
If possible do not sweep the ashes as this will stir
them into the air and disperse them into the room.
The closed container of ashes should be placed on
a noncombustible floor or on the ground, well away from all
combustible materials, pending final disposal. If the ashes are
disposed of by burial in soil or otherwise locally dispersed,
they should be retained in the closed container until all cinders
have thoroughly cooled.
8. Inspection and Cleaning:
At least twice a year in warm climates or monthly
during the heating season in colder climates, thoroughly
inspect the Fire-Lite fireplace and chimney system.
Chimneys must be installed so that access is provided for
inspection and cleaning. The chimney should be inspected
monthly during the heating season.
Inspect the entire flue from the top down for
obstructions such as birds’ nests, leaves, etc. Such obstructions
must be removed.
Check spark arrestor screens for clear flow of smoke
every two to four weeks during the heating season.
Inspect the flue periodically during the heating season
for the presence of soot and creosote build up. If creosote or
soot has accumulated, it should be removed to reduce the risk
of chimney fire.
Have your chimney cleaned by a professional chimney
sweep if you have doubts about your ability to do it.
Use a plastic, wood or steel brush to clean the chimney.
Scrub the spark arrestor/chimney cap with a wire
brush.
Remove any chimney cap for flue cleaning from the
top. Open the damper in the firebox for cleaning access from
below.
Clean the inner portion of the flue by using a flexible
handled chimney cleaning brush.
For straight run flue the proper size brush can be pulled
up through the flue from the firebox with the damper open.
If the chimney has an offset chimney section, brush
cleaning from the chimney top down to the offset/return and
then from the firebox up to the offset section is the proper
method.
In either case, cover the fireplace opening with a damp
sheet (sealed to the opening with masking tape) before brush
cleaning. Do not remove sheet until the soot has settled. It is
advised to vacuum loosened soot. Do not sweep loosened soot
as sweeping will disperse soot into the air and about the room.
WARNING:
Do not use chemical fireplace and chimney
cleaners that are poured on a hot fire. These can be dangerous
and generally work only on the flue section nearest the fire,
leaving the rest of the flue unaffected.
9. Exterior Maintenance:
Annually, at a minimum, check all metal flashings and
weather seals around the exterior chimney where it penetrates
the roof surface; inspect any chimney top spark arrestors, metal
cowlings and weather hoods to make sure they are secure and
weather tight.
Seal any cracks or gaps in chimney-to-roof flashings
to prevent possible roof and chimney chase leaks.
Inspect any cement chimney cap or clay chimney pot
terminations to make sure they are not diverting water into the
structure. Seal any suspected cracks or gaps in these masonry
components.