Step 8: Center the Catalytic Combustor in the firebox and rest
it on top of the support brackets making sure that the filter is
equally settled on the brackets. The filter should be set toward
the rear of the firebox.
Step 9: If grouting the inside of the sidewalls, leave the top 1
3/4” without grout or else measure and locate the mounting
clip to the exact dimension (based on the thickness of the brick
& mortar used to line the inside of the firebox backwall).
Step 10: Set the back smoke dome component across the rear
side walls in a bed of mortar and flush with the back face of the
back wall.
Set the front smoke dome component in mortar across
the front side walls flush with the front of the sidewalls.
Step 11: Position the smoke dome’s sloping sidewalls at each
end of the smoke dome components.
The sloping sidewalls fit in between the front and rear
smoke dome components and also fit into the haunches at the
ends of the front and rear smoke dome components. Mortar all
contact surfaces thoroughly.
Note: The smoke dome sloping sidewalls have a beveled
bottom edge so that they will sit tight onto the flat top of the
side walls.
Step 12: Make sure that all component contact surfaces have
been properly sealed with approved mortar.
Check smoke dome front and back walls to see that
they are plumb, level and in alignment with mating components.
Check alignment of the smoke dome sloping sidewall
components to see that they are fully seated.
Step 13: Set the smoke dome top plate into position on top of
the smoke dome wall assembly.
One side of the smoke dome top plate shows a
thickened center. This side is the bottom face of the top plate.
The fourteen inch (14”) diameter flue hole in the top
plate is centered in the smoke dome from side to side but is
offset from front to back.
Make sure that the top plate is set so that the flue hole
is closer to the back wall of the smoke dome assembly.
Be sure to set the smoke dome top plate flush with the
front, back and sides of the smoke dome assembly. All contact
surfaces must be properly sealed with the approved mortar.
Note: The completed smoke dome assembly should present a
stable and level surface for setting the flue components.