INSTALLATION
PAGE 8
FIREPLACE INSTALLATION
BV4000C MINIMUM FIREPLACE DIMENSIONS
Approx. minimum
Height: 21”
dimensions into fireplace
Width: 22 ½”
Depth: 16”
CATALYTIC TEMPERATURE PROBE
Install temperature probe prior to installing insert
.
To install the
Catalytic Temperature Probe
locate the
plug on the top, right-hand side of the bypass control
rod. Remove the plug, install the sleeve, and place
probe in sleeve. It may be necessary to bend the
flange on the plug so it won't interfere with the probe
temperature indicator.
The Catalytic Temperature Probe is provided so you
can monitor the temperature of your Catalytic Com-
bustor. Once you have established a fire and the
Catalytic Temperature Probe indicates the tempera-
ture of your Catalytic Combustor is between 500° -
600° F (approximately 20 - 25 minutes) close the By-
pass Damper Control. Depending on the type and size
of the fuel load as well as the length of time the stove
has been burning, your Catalytic Combustor should
operate between 1000 - 1800° F.