CARE AND OPERATION
PAGE 16
BYPASS DAMPER CONTROL
The operating handle of your bypass damper control is lo-
cated on the front of the stove flue collar. By moving the by-
pass damper control, the operator can route the fire either
through the catalytic combustor (pushed in) or directly up the
flue (pulled out). When starting a fire or refueling, the bypass
damper control should be pulled out. Once the fire is estab-
lished, it should be pushed in.
CATALYTIC TEMPERATURE PROBE
The catalytic temperature probe monitors the tempera-
ture of your catalytic combustor. Once you have estab-
lished a fire and the catalytic temperature probe indi-
cates the temperature of your catalytic combustor.
When it reaches a temperature between 500 to 600 de-
grees (approximately 20 - 25 minutes), close the bypass
damper control. Depending on the type and size of the
fuel load as well as the length of time the stove has
been burning, your catalytic combustor should operate –
between 1000 to 1800 degrees.
When the blower is operating it will affect the temperature
probe reading. Turn the blower off for an accurate reading.