![Eagle EV-30 Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/eagle/ev-30/ev-30_owners-manual_3294768085.webp)
rev_0.6
85 / 135
You can set piercing parameters in the Pierce tab.
There are four piercing modes, no piercing, single stage, two stages and three stages piercing. Each piercing
stage has a same set of parameters.
Parameter
Description
Step time
The feeding time from the piercing height of the current stage to the height of the next
stage.
Pierce
height
The initial space between the nozzle and the sheet in the current piercing stage.
Pierce gas
The assist gas for piercing.
Gas
pressure
Pressure of the assist gas, valid only for gases controlled via electrical regulator, e.g. O
2
.
Peak
power
The nominal laser power set in percentage.
Duty
cycle
Duty of the PWM control signal set in percentage.
Содержание EV-30
Страница 32: ...rev_0 6 32 135 10 Turn on the computer Turn on the computer on 3kW lasers Turn on the computer on 6kW lasers...
Страница 41: ...rev_0 6 41 135 Machining Now you can start machining the parts...
Страница 126: ...rev_0 6 126 135 3 Remove the access panel on top of the Z axis...
Страница 127: ...rev_0 6 127 135 4 Remove the covers of the X axis drag chain...
Страница 129: ...rev_0 6 129 135 7 Remove the corner access panel of the X Y intersection...
Страница 133: ...rev_0 6 133 135 2 Remove the laser head from the Z axis slider...