WIRING INSTRUCTIONS

CONDITION OF ACCEPTANCY

1)

This equipment must be installed in an all-metal fixture of steel or stainless steel construction, 0.050˝ minimum

thickness for the top and supporting frame. Side enclosures to be at least 22 gauge minimum thickness.

2)

A removable bottom enclosure must be provided under each drop-in unit, and must be of all-metal construction

of at least 22 gauge minimum. If ventilating openings are provided, they must not allow the entrance of a 3/4˝-

diameter rod; must not be located directly below uninsulated live terminals, wiring, or electrical components;

and must be located at least 1˝ away from any insulated live terminals.

3)

Minimum spacing between drop-ins or edges shown in

Step 1

(page 2).

4)

Controls shall be mounted on the front vertical surface of the fixture.

5)

Cabinet supply wires shall have minimum temperature rating of 220˚F (105˚C).

CAUTION:

Temperature in control area must not exceed 220˚F (105˚C).

3

Wiring diagram - Infinite control

Wiring diagram - Thermostatic control

Please note:

• Connect power supply to 15˝ power leads.

• Be sure to connect ground to green wire.

Содержание BM1220FW-120

Страница 1: ... keep food from drying out It is not designed for cooking foods but merely to keep hot foods at desired temperatures for serving During initial operation a little smoke or odor may be detected This will occur when the coating on the heating element burns off This should stop after 1 2 hour of operation This warmer is equipped with a variable control for different heat selections Suffix 120 may be ...

Страница 2: ...control knob mounting screws 2 screws or rivets not included 4 recessed control panel Step 4 Attach controls Remove control from recessed control panel by removing knob and two mounting screws With indicator light still attached to panel insert recessed control panel through 23 4 x 51 8 cutout from rear of enclosure Remount control to recessed control panel and attach knob Recessed control panel s...

Страница 3: ...ot allow the entrance of a 3 4 diameter rod must not be located directly below uninsulated live terminals wiring or electrical components and must be located at least 1 away from any insulated live terminals 3 Minimum spacing between drop ins or edges shown in Step 1 page 2 4 Controls shall be mounted on the front vertical surface of the fixture 5 Cabinet supply wires shall have minimum temperatur...

Страница 4: ...f power disconnect switch 4 Unit should be operated with feet provided to prevent overheating and damage to countertop or cord Check feet every 30 days to assure they are tight 5 Check cord and plug appearance for damage cracking or deterioration If visible have both replaced by an authorized service agency This equipment is designed and sold for commercial use only by personnel trained and experi...

Отзывы: