WIRING INSTRUCTIONS
CONDITION OF ACCEPTANCY
1)
This equipment must be installed in an all-metal fixture of steel or stainless steel construction, 0.050˝ minimum
thickness for the top and supporting frame. Side enclosures to be at least 22 gauge minimum thickness.
2)
A removable bottom enclosure must be provided under each drop-in unit, and must be of all-metal construction
of at least 22 gauge minimum. If ventilating openings are provided, they must not allow the entrance of a 3/4˝-
diameter rod; must not be located directly below uninsulated live terminals, wiring, or electrical components;
and must be located at least 1˝ away from any insulated live terminals.
3)
Minimum spacing between drop-ins or edges shown in
Step 1
(page 2).
4)
Controls shall be mounted on the front vertical surface of the fixture.
5)
Cabinet supply wires shall have minimum temperature rating of 220˚F (105˚C).
CAUTION:
Temperature in control area must not exceed 220˚F (105˚C).
3
Wiring diagram - Infinite control
Wiring diagram - Thermostatic control
Please note:
• Connect power supply to 15˝ power leads.
• Be sure to connect ground to green wire.