Updating the eLogger’s Firmware 

 
Each time a new version of our software is installed, the software will 
check the firmware version of the eLogger, and will prompt you to 
update the firmware if a new version is available.    Always update the 
firmware if prompted to do so.   When new firmware is available, the 
“Firmware Control” screen will appear.  Simply click the “Click Here 
to Update Recorder Firmware Version” to start the firmware update 
process. 

 

Setting up the eLogger with the 
Windows Software 

 
Once the software is installed, run the software as described above.   
The first time the software is launched, the New Model Wizard will be 
invoked. 
 
The Wizard will prompt you to install the eLogger using the supplied 
USB cable.   
  
When you do this for the first time, the behavior will be different 
depending on which version of Windows you are using: 
 
 
Windows 7™, Windows Vista™, Windows 2000 ™ and Windows 
XP ™
:  When the eLogger is first connected to the USB port, 
Windows should automatically install the correct drivers without prompting you.   If you should receive a Windows prompt, however, 
do what it says. 
 
Windows 98SE™ and Windows Millennium™
:   When the eLogger is first connected to the USB port, the New Hardware Wizard 
will likely appear.   Follow the steps in the Wizard, choosing the options to allow Windows to find the appropriate drivers for the 
eLogger – these drivers are built into Windows.   If the devices you already have on your computer haven’t required the installation of 
the USB drivers, Windows will prompt you for your Windows CD to copy over the drivers.     Once this process is complete, you may 
be asked to reboot the system.   Reboot at this point, then launch the eLogger Software, and the New Model Wizard should start up 
again.    
 
Windows 98™:  The eLogger and software are not compatible with Windows 98. 

 
Telling the eLogger what to Log

 

 
The first time you run the software, you will be prompted to choose what  parameters you wish the eLogger  to record, using the 
dialog box shown below.  Note that this dialog box can be accessed at any time, by clicking “Hardware, Choose Parameters you want 
to Log in the Recorder.” 
 

Содержание eLogger V4

Страница 1: ...e logged to permanent memory which retains the data even when the power is removed Fully compatible with our OSD Pro expander Includes Y cable for throttle position logging Great for bench monitoring...

Страница 2: ...cting the eLogger to Your Model s Power System WARNING High Voltages can cause electric shock Be extremely careful when working with high voltage packs Work with high voltages at your own risk IMPORTA...

Страница 3: ...our eLogger Note see the instruction manuals accompanying your sensors or accessories for instructions on how to connect and configure them Measuring Temperature with the eLogger Up to three optional...

Страница 4: ...rong suitable glue It s important that the red line on the magnets faces away from the sensor once the sensor is installed When using two magnets the magnets should be glued 180 degrees apart to keep...

Страница 5: ...e Position with the eLogger IMPORTANT Do not use the throttle Y cable if your receiver is powered with greater than 6 Volts Make sure you connect the battery pack to the eLogger only AFTER connecting...

Страница 6: ...to check to see if a newer version of our software is available To install the software just place the CD in the CD ROM drive If AutoPlay is enabled on your PC the setup program should run automatica...

Страница 7: ...cted to the USB port Windows should automatically install the correct drivers without prompting you If you should receive a Windows prompt however do what it says Windows 98SE and Windows Millennium W...

Страница 8: ...optional Airspeed MicroSensor Altitude Choose this option if you want to record altitude with the optional Altitude MicroSensor Servo Current Choose this option if you want to record servo current wi...

Страница 9: ...ture The eLogger Software can display several model parameters in both numeric and instrument format on the main screen Select the parameters you wish the software to display on the PC screen by click...

Страница 10: ...Copyright 2003 2010 Eagle Tree Systems LLC Page 10 Note Select the Metric checkbox on this dialog if you want values displayed in metric units...

Страница 11: ...installed to ensure that there is no impact on your system Make sure that your antenna down operating range is within the manufacturer s specifications See your Radio owner s manual for the correct pr...

Страница 12: ...l and or Numeric Temperatures The software can display up to two Temperature readings in either gauge or numeric format Graphical and or Numeric RPM The software displays RPM readings in either gauge...

Страница 13: ...sheet Compatibility The eLogger software has extensive graphing capability built in Just click Data 2D Chart in the software to graph loaded data Note that individual sessions of the file can be graph...

Страница 14: ...due to a disconnected sensor etc Set Min Max Value This feature lets you select the Minimum and or Maximum value that will be displayed and charted for a particular parameter This feature is useful t...

Страница 15: ...down immediately if the power goes below around 5 volts for more than a few milliseconds and logs this occurrence when the power returns to above 5 volts If your battery s voltage frequently drops th...

Страница 16: ...See the Software license agreement for more information on Software restrictions Problems that result from o External causes such as accident abuse misuse or problems with electrical power o Servicin...

Страница 17: ...______________________ Where did you purchase your product _________________________________________________ Where did you hear about our product _______________________________________________ Any fe...

Отзывы: