First Line:  Model Name 
Second Line: Data about your Model’s setup.   This line is needed to allow sharing of your session log files with others. 
Third line:  header indicating what each of the data fields represents.  In the current software, these columns are: 

 

 

 

If “IsEvent” is 1, the record contains event data as well as regular data.   Typical events are power-up (restart), and servo glitches. 
Ignore the non-event fields when IsEvent is set to 1. 
 
Event Codes in the “EventCode” field are as follows.  Note that codes other than those below should be reported to Eagle Tree 
Systems: 

 

 

 

9 = ERROR_RESTART: The eLogger has been started or restarted (power was applied) 

 

18 = ERROR_GPS_DATA_PACKET:  GPS Data was received from the GPS Expander, 

 

27 = ERROR_SPEKTRUM_DATA_PACKET: Data was received from the AR9000 Interface 

 

 

Milliseconds indicates when each record was collected, in Milliseconds since the eLogger was turned on. 
Email us if you need more information on the file format. 
 

Advanced Software Features 

 
There are many advanced features included with our software, available via the “Advanced” tab in the software.  Some of these are 
described below: 
 

Set Logging Triggers

 

This feature lets you select events that will cause logging to start, such as elapsed time after power-up, or threshold readings for 
amperage, RPM, Altitude, or when GPS fix is attained.   Note that until the selected event occurs, the eLogger will be in “paused” 
mode, and the LED will flash two blinks in a row.  If you set a logging trigger, don’t forget about setting it, since it can be confusing if 
the eLogger is not logging due to a disconnected sensor, etc. 
 

Set Min/Max Value

 

This feature lets you select the Minimum and/or Maximum value that will be displayed and charted for a particular parameter.   This 
feature is useful to filter out “glitches” in the data, should they occur.   Setting a maximum value for RPM, for example, will filter out 
RPM values above the set value, which can improve the visualization of the data when charting. 

  
Calibrate Pack Voltage and Amperage 

The eLogger’s voltage and amperage measurement system is factory calibrated.   If you’d prefer that the eLogger’s readings match 
the readings of another instrument you are accustomed to using, the calibration feature is included.  However, if your eLogger is 
reading inaccurately, please see the troubleshooting section below before recalibrating. 
 
 Happy Modeling!! 
 

Troubleshooting 

 
Below is a list of problems that may be encountered, and steps to remedy them.    
 
A good first step to troubleshooting, if you are able to connect your eLogger to your PC, is to download our latest software and update 
the eLogger’s Firmware via “Hardware, Firmware Control.”   Doing this will ensure that you have the latest software and firmware 
available.   Just click “Help, Download latest updates…” in the software to check to see if a newer version of our software is available. 
 
 If your particular issue is not addressed by this update, or by the suggestions below, please visit our web support page for additional 
support options, at 

http://www.eagletreesystems.com/Support/support.html

.     

 

 

Issue:  My PC does not recognize the eLogger. 
Solution:  Try to eliminate the problem in the following ways: 

Milliseconds  IsEvent 

EventError  EventData  Altitude  Airspeed  ServoCurrent*100  Throttle 

PackVolt*100 

Amps*100 

Temp1*10 

Temp2*10 

Temp3*10 

RPM 

 

GPSLat 

GPSLon  GPSAlt 

GPSSpeed 

GPSCourse  GPSDist 

GPSUTC 

NumSats  GPSFlags 

Содержание eLogger V4

Страница 1: ...e logged to permanent memory which retains the data even when the power is removed Fully compatible with our OSD Pro expander Includes Y cable for throttle position logging Great for bench monitoring...

Страница 2: ...cting the eLogger to Your Model s Power System WARNING High Voltages can cause electric shock Be extremely careful when working with high voltage packs Work with high voltages at your own risk IMPORTA...

Страница 3: ...our eLogger Note see the instruction manuals accompanying your sensors or accessories for instructions on how to connect and configure them Measuring Temperature with the eLogger Up to three optional...

Страница 4: ...rong suitable glue It s important that the red line on the magnets faces away from the sensor once the sensor is installed When using two magnets the magnets should be glued 180 degrees apart to keep...

Страница 5: ...e Position with the eLogger IMPORTANT Do not use the throttle Y cable if your receiver is powered with greater than 6 Volts Make sure you connect the battery pack to the eLogger only AFTER connecting...

Страница 6: ...to check to see if a newer version of our software is available To install the software just place the CD in the CD ROM drive If AutoPlay is enabled on your PC the setup program should run automatica...

Страница 7: ...cted to the USB port Windows should automatically install the correct drivers without prompting you If you should receive a Windows prompt however do what it says Windows 98SE and Windows Millennium W...

Страница 8: ...optional Airspeed MicroSensor Altitude Choose this option if you want to record altitude with the optional Altitude MicroSensor Servo Current Choose this option if you want to record servo current wi...

Страница 9: ...ture The eLogger Software can display several model parameters in both numeric and instrument format on the main screen Select the parameters you wish the software to display on the PC screen by click...

Страница 10: ...Copyright 2003 2010 Eagle Tree Systems LLC Page 10 Note Select the Metric checkbox on this dialog if you want values displayed in metric units...

Страница 11: ...installed to ensure that there is no impact on your system Make sure that your antenna down operating range is within the manufacturer s specifications See your Radio owner s manual for the correct pr...

Страница 12: ...l and or Numeric Temperatures The software can display up to two Temperature readings in either gauge or numeric format Graphical and or Numeric RPM The software displays RPM readings in either gauge...

Страница 13: ...sheet Compatibility The eLogger software has extensive graphing capability built in Just click Data 2D Chart in the software to graph loaded data Note that individual sessions of the file can be graph...

Страница 14: ...due to a disconnected sensor etc Set Min Max Value This feature lets you select the Minimum and or Maximum value that will be displayed and charted for a particular parameter This feature is useful t...

Страница 15: ...down immediately if the power goes below around 5 volts for more than a few milliseconds and logs this occurrence when the power returns to above 5 volts If your battery s voltage frequently drops th...

Страница 16: ...See the Software license agreement for more information on Software restrictions Problems that result from o External causes such as accident abuse misuse or problems with electrical power o Servicin...

Страница 17: ...______________________ Where did you purchase your product _________________________________________________ Where did you hear about our product _______________________________________________ Any fe...

Отзывы: