INSTRUCTIONS
AutoFill
®
Water System
1. Attach a continuous flowing hot water source to the
3
⁄
8
˝ compression water connection inlet.
2. Screw the barbed fitting into the drain line and connect a
1
⁄
2
˝ tube for the overflow drain. run to an appropriate floor sink.
3. Plug unit into proper power source stated on model/serial plate. Turn water source on and the AutoFill
®
ON/OFF switch to “ON”.
(Remember that the solenoid will make a “pop” sound the first time this is turned on.) The AutoFill
®
system will fill and maintain the
proper water level in all wells. If there is a desire to run the unit without automatically filling the wells with water, simply turn the
ON/OFF switch to the “OFF” position. The AutoFill
®
system runs independently of the hot wells, so the wells are still operational.
For further details about the AutoFill
®
Water System, call the factory at 1-800-441-8440.