ASSEMBLY INSTRUCTIONS

Q-LEVER Cantilever Shelving 

READ BEFORE ASSEMBLING OR USING SHELVING

WARNING

FOR  YOUR  SAFETY

These instructions and safety information should be reviewed with all store personnel, and along with all other

instructions  for  your  Eagle  Group  products,  must  be  preserved  and  provided  to  any  subsequent  user  or

purchaser of these fixtures. 

• Install all shelving according to installation and use components only as instructed. Shelving and components

should only be installed and rearranged by trained personnel who have read and understand these instructions

and warnings. 

• Local codes and regulations concerning building, fire, sanitation, or seismic requirements may apply to some

installations. It is the responsibility of the owner of these fixtures to check with local building authorities to

determine what codes or regulations, if any apply and always install the shelving in compliance with any such

requirements. 

• When installing or rearranging shelving, never move assembled shelving. 

• Do NOT combine Eagle products with non-Eagle products. 

• NEVER use damaged parts. Damaged parts may cause shelving to be structurally unsafe or create exposure

to sharp or pointed edges. If parts were damaged in shipment, do not use and contact your Eagle Customer

Service  Representative.  If  parts  are  damaged  after  shipment,  discontinue  use  immediately  and  order

replacement parts. 

• Do NOT exceed allowable load limits. Exceeding allowable loads may cause the shelving to tip over or collapse. 

• Bottom shelf is required for structural integrity and stability. Use of shelving without the shelf may cause the

shelving to collapse. 

• Do NOT lean tall or heavy items against shelving unless shelving is anchored to the floor or is otherwise braced

to prevent overturning. The weight and force of leaning items on anchors or unbraced shelving may cause the

shelving to overturn or collapse. 

• Shelving (or racks) that are leaning or bending when loaded may indicate a dangerous overload or impending

collapse. Loads should be immediately reduced, and the cause for this condition should be corrected, before

reloading. Refer to appropriate installation instructions to assure shelving (or racks) are properly assembled,

replace any damaged components or parts, and do not exceed recommended maximum loads or engage in

any other unsafe use of the shelving (racks). 

• Provide safe access to all levels of storage & display shelving in accordance with applicable OSHA regulations.

Never allow anyone to climb, walk, or stand in shelving. These shelves were not designed to withstand the

extra weight and impact of climbing, walking and standing, and the added weight and impact of such actions

may cause the fixture to collapse. 

• Never alter, modify or otherwise structurally change the shelving or any of its component parts. Modification

or alteration may cause the shelving or component part to become structurally unsafe, resulting in tipping,

collapse or other failure of the fixture. 

Содержание Q-LEVER unit with all-wire shelving

Страница 1: ...mbling shelving unit read this instruction manual carefully to ensure correct use After reading be sure to store this instruction in a safe place should it be needed for future reference Warranty If t...

Страница 2: ...replacement parts Do NOT exceed allowable load limits Exceeding allowable loads may cause the shelving to tip over or collapse Bottom shelf is required for structural integrity and stability Use of s...

Страница 3: ...s Units with Bottom Dunnage Shelf 24 to 72 600 lbs 600 lbs 1 000 lbs 2 800 lbs WARNING THE DEPTH OF THE LOAD SHOULD NEVER EXCEED THE LENGTH OF THE SHELF BRACKET Maximum capacities based on evenly dist...

Страница 4: ...figure 2a brace uprights Step 3 Attach top half of X BRACE to uprights and assemble X BRACE Align top half of X BRACE with hole on each upright as shown below Run 5 16 24 bolt through lock washer fla...

Страница 5: ...o upright Install opposite bracket at same height shelf mat bracket brackets dunnage shelf QLOK Quick Note QLOK in place bracket upright Step 6 Install brackets onto uprights at desired location Quick...

Страница 6: ...brace figure 8b until snug Don t forget Install warning labels in visible location End figure 8a figure 8b Place the shelf onto pair of brackets lowering the corner collars of shelf onto the four bra...

Страница 7: ...installing shelves tighten bolts as indicated in Step 8 5 16 bolt 5 16 bolt 5 16 bolt flat washer flat washer lock washer lock washer lock washer flat washer X brace flat washer lock washer 5 16 bolt...

Страница 8: ...oulevard Clayton Delaware 19938 8903 U S A www eaglegrp com Phone 302 653 3000 Foodservice 800 441 8440 MHC Retail 800 637 5100 Fax 302 653 2065 ASSEMBLY INSTRUCTIONS Q LEVER Cantilever Shelving Q LEV...

Отзывы: