![Eagle Equipment MTP-11V3 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/eagle-equipment/mtp-11v3/mtp-11v3_installation-and-operation-manual_3274794030.webp)
EAGLE MTP-11V3 Product Manual
30
IMPORTANT
STEP 18
POWER UNIT PRIMING PROCEDURE
THE PROBLEM: Power unit runs fine but will not pump any fluid.
Step 1
– Locate the check valve, the flush plug to the left of the lowering valve.
(See illustration below.)
Step 2
– Using an Allen wrench and shop towel – with shop towel in place to
catch fluid – loosen the check valve plug 2-1/2 turns to allow it to leak.
Step 3
– Push the
START
button for one second, then release for three seconds.
Repeat these steps until the unit starts pumping fluid.
Step 4
– Tighten the check valve.
THE POWER UNIT SHOULD BE PRIMED
Содержание MTP-11V3
Страница 19: ...EAGLE MTP 11V3 Product Manual 19 Fig 11a Fig 11b Mainside Lock Installed Offside Lock Installed Fig 11c Fig 11d...
Страница 20: ...EAGLE MTP 11V3 Product Manual 20 Fig 11e Fig 11f...
Страница 32: ...EAGLE MTP 11V3 Product Manual 32 Fig 22...
Страница 39: ...EAGLE MTP 11V3 Product Manual 39...
Страница 40: ...EAGLE MTP 11V3 Product Manual 40 SUPPLEMENTAL...
Страница 41: ...EAGLE MTP 11V3 Product Manual 41...
Страница 42: ...EAGLE MTP 11V3 Product Manual 42...
Страница 43: ...EAGLE MTP 11V3 Product Manual 43...