Input Terminals
Change
Function
Code
Setting Range
Default
Parameter Name
0: No function
1: Forward RUN (FWD) or running command
2: Reverse RUN (REV) or running direction
(Note: F4-11 must be set when F4-00 is set to
1 or 2.)
3: Three-wire control 4: Forward JOG (FJOG)
5: Reverse JOG (RJOG) 6: Terminal UP
7: Terminal
Y
WN 8: Coast to stop
9: Fault reset (RESET) 10: RUN pause
11: External fault normally open (NO) input
12: Multi-reference terminal 1
13: Multi-reference terminal 2
14: Multi-reference terminal 3
15: Multi-reference terminal 4
16: Terminal 1 for acceleration/ deceleration
time selection
17: Terminal 2 for acceleration/ deceleration
time selection
18: Frequency source switchover
19: UP and
Y
WN setting clear (terminal,
operating panel)
20: Running command switchover terminal 1
21: Acceleration/Deceleration prohibited
22: PID pause 23: PLC status reset
24: Wobble pause 25: Counter input
26: Counter reset 27: Length count input
28: Length reset
29: Torque control prohibited
30: Pulse input (enabled only for
S
5)
31: Reserved
32: Immediate DC injection braking
33: External fault normally closed (NC) input
34: Frequency modification enabled
35: PID action direction reverse
36: External STOP terminal 1
37: Running command switchover terminal 2
38: PID integral disabled
39: Switchover between main frequency source
and preset frequency
40: Switchover between auxiliary frequency
source and preset frequency
41: Motor terminal selection
42: Reserved
43: PID parameter switchover
44: User-defined fault 1
45: User-defined fault 2
46: Speed control/Torque control switchover
47: Emergency stop
48: External STOP terminal 2
49: Deceleration DC injection braking
50: Clear the current running time
51: Two-wire/Three-wire mode switchover
52: Reverse frequency forbidden
53-59: Reserved
F4
-
00
S1 terminal
function
1
★
F4
-
01
S2 terminal
function
4
★
F4
-
02
S3 terminal
function
9
★
F4
-
03
S4 terminal
function
12
★
F4
-
04
S5 terminal
function
13
★
F4
-
05
S6 terminal
function
0
★
F4
-
10
S
filter time
☆
0.000s to 1.000s
0.010s
F4
-
11
Terminal control
mode
★
0: Two-wire control mode 1
1: Two-wire control mode 2
2: Three-wire control mode 1
3: Three-wire control mode 2
0
F4
-
12
Terminal UP/
Y
WN
rate
☆
0.001Hz/s~65.535Hz/s
1.00Hz/s
F4
-
13
F4
-
14
F4
-
15
F4
-
16
☆
☆
☆
☆
F4
-
17
☆
F4
-
28
☆
F4
-
29
F4
-
30
F4
-
31
☆
F4
-
32
☆
AI curve 1
minimum input
0.00V~F4-15
0.00V
AI curve 1
minimum input
corresponding
setting
-100.0%~+100.0%
0.0%
AI curve 1
maximum input
F4
-
13~+10.00V
10.00V
AI curve 1
maximum input
corresponding
setting
-100.0%~+100.0%
100.0%
AI1 filter time
0.00~10.00s
0.10s
F4
-
18
F4
-
19
F4
-
20
F4
-
21
☆
☆
☆
☆
F4
-
22
☆
AI curve 2
minimum input
0.00V~F4-20
0.00V
AI curve 2
minimum input
corresponding
setting
-100.0%~+100.0%
0.0%
AI curve 2
maximum input
F4
-
18~+10.00V
10.00V
AI curve 2
maximum input
corresponding
setting
-100.0%~+100.0%
100.0%
AI2 filter time
0.00~10.00s
0.10s
F4
-
23
AI curve 3
minimum input
-10.00V~F4-25
-10.00V
☆
F4
-
24
-100.0%
☆
AI curve 3
minimum input
corresponding
setting
-100.0%~+100.0%
F4
-
25
AI curve 3
maximum input
F4-23~+10.00V
10.00V
AI curve 3
maximum input
corresponding
setting
F4
-
26
-100.0%~+100.0%
100.0%
☆
☆
F4
-
27
Keyboard
potentiometer
filter time
0.00s~10.00s
0.10s
☆
PULSE
minimum input
PULSE minimum
inputcorresponding
setting
0.00kHz~F4-30
0.00kHz
-100.0%~100.0%
0%
☆
PULSE
maximum input
PULSE maximum
inputcorresponding
setting
F4-28~100.00kHz
50.00kHz
☆
-100.0%~100.0%
100.0%
PULSE
filter time
0.00s~10.00s
0.10s