0000 to FFFF
BIT0 0:PID feedback
BIT0 1:PLC stage
BIT0 2:Pulse reference(kHz)
BIT0 3:Running frequency 2(Hz)
BIT0 4:Remaining running time
BIT0 5:AI1 voltage before correction(V)
BITO 6:AI2 voltage before correction(V)
BIT0 7:Keyboard potentiometer 
voltage before correction
BITO 8:Linear speed
BIT0 9:currentpower-on time(h)
BITO 10:currentpower running time(Min)
BIT0 11:Pulse reference(Hz)
BITO 12:Communication reference
BIT0 13:Enceder feedback speed(Hz)
BITO 14:Main frequency X display(Hz)
BIT0 15:Auxiliary frequency Y display(Hz)

F7-04

LED display 

running 

parameters 2

0

33

F7-06

Product number

0h to 65535h

1.0000

Performance 

software 

version

-

Number of decimal

places for load

speed display

BIT0:Number of decimal places for U0-14
0:No decimal places
1:One decimal places    2:Two decimal places
BIT1:Number of decimal places for U0-19/
U0-29
1:One decimal places    2:Two decimal places

  F u n c t i o n C o d e T a b l e

EC590

 

  F u n c t i o n C o d e T a b l e

EC590

 

F7-13

Accumulative power

on time

0 to 65535h

Accumulative power

consumption

F8-00

Jog frequency

refence

0.00Hz to the maximum frequency

2.00Hz

 0.00Hz to the maximum frequency

0

.

00Hz

 

-

10

.

00

 to 10

.

00

Accept data gain 

(frequency)

Forward/Reverse 
run switch over

dead-zone time

Reverse RUN 
selection

 0.0s to 3000.0s

0.0s

Running mode when

frequency lower

than frequency

lower limit

0

Droop rate

0h

F7-05

Display stop

parameter

0000 to FFFF
BIT0 0:Frequency reference(Hz)
BIT0 1:Bus voltage
BIT0 2:S state
BIT0 3:YO state
BIT0 4:AI1 voltage(V)
BIT0 5:AI2 voltage(V)
BITO 6:Keyboard potentiometer 
voltage 
BIT0 7:Count value
BITO 8:Length value
BIT0 9:PLC stage
BITO 10:Load speed
BIT0 11:PID reference
BITO 12:Pulse reference (kHz)

Load speed

display 

coefficient

0.0001 to 6.5000

F7-07

Inverter module

heat sink

temperature

-20

to 120

-

F7-08

-

-

F7-09

Accumulative 
running time

-

F7-10

-

F7-11

Function 
software 

version

-

-

F7-12

20

-

F7-14

0 to 65535kWh

-

F8 Auxiliary Functions

Change

Function 

Code

Setting Range

Default

 

Parameter Name

F8-01

Jog acceleration

time

0.0s to 6500.0s

0.0s to 6500.0s

Jog deceleration

time

F8-02

20.0s

20.0s

F8-03

Acceleration time

2

0.00s to 650.00s (F0-19=2)
0.0s to 6500.0s

(F0-19=1)

0s to 65000s (F0-19=0)

Deceleration time

2

0.00s to 650.00s (F0-19=2)
0.0s to 6500.0s

(F0-19=1)

0s to 65000s (F0-19=0)

Model

dependent

Model

dependent

Model

dependent

Model

dependent

F8-04

F8-05

F8-06

F8-07

F8-08

Acceleration time

3

Deceleration time

3

0.00s to 650.00s (F0-19=2)
0.0s to 6500.0s

(F0-19=1)

0s to 65000s (F0-19=0)

0.00s to 650.00s (F0-19=2)
0.0s to 6500.0s

(F0-19=1)

0s to 65000s (F0-19=0)

0.00s to 650.00s (F0-19=2)
0.0s to 6500.0s

(F0-19=1)

0s to 65000s (F0-19=0)

0.00s to 650.00s (F0-19=2)
0.0s to 6500.0s

(F0-19=1)

0s to 65000s (F0-19=0)

Acceleration time

4

Deceleration time

4

0.0s

0.0s

F8-09

1.00

F8-10

Frequency jump 2

F8-11

Frequency jump 

band

 0.00Hz to the maximum frequency

0

.

00Hz

F8-12

F8-13

F8-14

F8-15

0

0:Disable            1:Enable 

0:Run at frequency reference lower limit
1:Stop
2:Run at zero speed

0

.

00% to 100.00%

0.00%

F8-16

Accumulative 
running time 

threshold

0

to 65000h

Содержание EC590 Series

Страница 1: ...0 in 2022 Copyright subject to change without notice Professional AC Drive Manufacturer ZHEJIANG EACN ELECTRONIC TECHNOLOGY CO LTD Address No 1 Jinhe Road Qinshan Street Haiyan County Jiaxing City Zh...

Страница 2: ...s 9 5 F4 Input Terminals 9 6 F5 Output Terminals 9 7 F6 Start stop control 9 8 F7 Operating panel and display 9 9 F8 Auxiliary Functions 9 10 F9 Fault and Protection 9 11 FA PID Function 9 12 FB Fixed...

Страница 3: ...e read carefully If you have any questions please contact with the agents of our company and our technicians are ready to serve you The instructions are subject to change without notice You can contac...

Страница 4: ...range of 0 0 6500 0s DC braking JOG control DC braking frequency 0 00 Hz to maximum frequency Braking time 0 0 100 0s Braking action current value 0 0 150 0 Simple PIC Multiple preset speeds JOG frequ...

Страница 5: ...It helps to avoid frequent overcurrent faults of the AC drive Timing control Time range 0 0 6500 0 minutes Individua lized functions Multiple communication protocols It supports Modbus Item Specifica...

Страница 6: ...171 160 130 127 4 5 1 5Kw 2 2Kw 4 0Kw 7 5Kw 18 5Kw 15Kw 126 146 170 115 131 151 320 186 256 175 243 305 158 174 198 155 171 195 4 5 6 6 30Kw 5 5Kw 11Kw 22Kw A Structure 45Kw 75Kw 180 250 120 170 489 6...

Страница 7: ...C 0V 10V 2 Impedance 22k 1 Input range DC 0V 10V 4mA 20mA decided by selection of F4 40 2 Impedance 22k voltage input 500 current input 10V GND 24V COM PLC AI1 GND AI2 GND Name External 10V power supp...

Страница 8: ...sudden load is added during operation 5 The AC drive model is of too small power class 6 Subject to external inter ference 1 Eliminate external faults 2 Perform the motor autotuning 3 Adjust the volta...

Страница 9: ...oard is faulty 4 The module is faulty 1 Eliminate external faults 2 Check whether the motor three phase winding is normal 3 Seek technical support 4 Seek technical support 13 14 Err14 Module overheat...

Страница 10: ...ameter protection password is set In the function parameter mode and user change parameter mode the parameter menu can only be entered after correctly entering the password Set FP 00 to 0 to cancel th...

Страница 11: ...anel keypad display 0 No function 1 Digital setting 2 AI1 3 AI2 4 Keyboard potentiometer 5 Pulse reference S5 6 Multi reference 7 Simple PLC 8 PID reference 9 Serial communication Tens terminal contro...

Страница 12: ...V F complete separation 11 V F half separation Default 0 Parameter Name F3 02 Cut off frequency of torque boost 0 00 Hz to the maximum frequency 50 00Hz F3 03 F3 04 F3 05 F3 06 F3 07 F3 08 Multi poin...

Страница 13: ...control switchover 47 Emergency stop 48 External STOP terminal 2 49 Deceleration DC injection braking 50 Clear the current running time 51 Two wire Three wire mode switchover 52 Reverse frequency forb...

Страница 14: ...specified count value reached 10 Length arrives 11 PLC cycle completed 0 2 F5 06 F5 07 0 Operationg frequency 1 Set frequency 2 Output current 3 Output torque torque absolute value 4 Output power 5 O...

Страница 15: ...l Change Function Code Setting Range Default Parameter Name 0 Speed tracking method 0 Start with stop frequency 1 Start from zero speed 2 Start from maximum frequency 0 F6 02 Speed tracking speed 1 10...

Страница 16: ...eference Hz BIT0 1 Bus voltage BIT0 2 S state BIT0 3 YO state BIT0 4 AI1 voltage V BIT0 5 AI2 voltage V BITO 6 Keyboard potentiometer voltage BIT0 7 Count value BITO 8 Length value BIT0 9 PLC stage BI...

Страница 17: ...d 0 00Hz F8 25 Switch over frequency of acceleration time 1 and acceleration time 2 0 00Hz to the maximum frequency F8 26 Switch over frequency of deceleration time 1 and deceleration time 2 0 00Hz to...

Страница 18: ...upon 3rd latest fault Current upon 3rd latest fault 3rd latest fault type F9 19 F9 20 Bus voltage upon 3rd latest fault S state upon 3rd latest fault Y state upon 3rd latest fault F9 21 Power on time...

Страница 19: ...reached Err29 0 Coast to stop 1 Stop according to the stop mode 2 Continue to run BIT3 Load lost Err30 0 Coast to stop 1 Deceleration to stop 2 Continue to run at 7 of rated motor frequency and restor...

Страница 20: ...d 0 00 to 60 00s 0 AI1 1 AI2 2 Keyboard potentiometer 3 AI1 AI2 4 Pulse reference S5 5 Communication reference 6 AI1 AI2 7 Max AI1 AI2 8 Min AI1 AI2 0 0 FA 03 PID operation direction 0 Forward 1 Rever...

Страница 21: ...ence 4 FC 29 FC 28 Running time of simple PLC reference 5 0 0s h to 6553 5s h Acceleration Deceleration time of simple PLC reference 4 0 to 3 Running time of simple PLC reference 6 FC 30 0 0s h to 655...

Страница 22: ...mmunication detection time FE 00 User defined parameter 0 U3 17 FE 01 User defined parameter 1 F0 00 F0 00 FC 47 Acceleration Deceleration time of simple PLC reference 14 0 to 3 Running time of simple...

Страница 23: ...ter 27 F0 00 FE 28 User defined parameter 28 F0 00 FE 29 User defined parameter 29 F0 00 F0 00 to FP xx A0 00 to Ax xx U0 00 to U0 xx U3 00 to U3 xx FP Parameter Management Change Function Code Settin...

Страница 24: ...2 10 A2 27 A2 28 Rotor resistance Leakage inductive reactance Mutual inductive reactance No load current Encoder pulses per revolution Encoder type 0 001 to 65 535 AC drive power 55 kW 0 0001 to 6 553...

Страница 25: ...0 DPWM switchover frequency upper limit 5 00 Hz to the maximum frequency 0 Asynchronous modulation 1 Synchronous modulation A5 02 Dead zone compensation mode selection 0 Disabled 1 Enabled compensatio...

Страница 26: ...ump range A7 User Programmable Card Change Function Code Setting Range Default Parameter Name 0 Disabled 1 Enabled A7 01 Control board output terminal control mode selection 0 0 AC drive control 1 Use...

Страница 27: ...tory corrected Factory corrected Factory corrected Factory corrected Factory corrected Factory corrected Factory corrected Factory corrected U Minimum Unit UO Monitoring Parameters Function Code Param...

Страница 28: ...de parameters some function codes cannot be changed only for manufacturers to use or monitor function code parameter address marking rules The rules are represented by the function code group number a...

Страница 29: ...BIT1 Y2 output control BIT2 RELAY1 output control BIT3 RELAY2 output control BIT4 Y4R output control BIT5 VY1 BIT6 VY2 BIT7 VY3 BIT8 VY4 BIT9 VY5 2001 Digital output terminal control write only Comman...

Страница 30: ...4 port is constrained by the functional parameter F5 00 and can be used as a high speed pulse output channel with a maximum output frequency of 50KHz when used as an open collector output Same specifi...

Отзывы: