EA Technology
CableData Collector Operating Manual
1365/L/01/1
Page 41 of 54
10.5
Data Analysis
Once testing is complete, collect all of the ZIP files that have been created during testing and
supply these files to EA Technology for analysis. EA Technology will produce a report with a
top level overview and more detail for each cable tested.
10.6
Restoring Software Default Options
It is possible to make changes to the options that appear in the CableData Collector
software. The list of
Voltages
and
Cable Types
can have user options added, as shown in
sections 10.4.5 and 10.4.7. If the additional options need to be removed, they can be using
the
Remove User Customisations
button. This removes all added options and will only
show the default ones.
From the software screen, click the
Settings
button, shown in Figure 59.
Figure 59 - Settings button on main screen
On the Settings screen, there is a button in the bottom left corner labelled
Remove User
Customisations
, visible in Figure 60.
Figure 60 - Remove User Customisations button
Содержание CableData CDC2
Страница 1: ...CableData Collector Operating Manual Product Code CDC2 Version 1 January 2013...
Страница 2: ......
Страница 50: ...EA Technology CableData Collector Operating Manual 1365 L 01 1 Page 46 of 54...
Страница 59: ......