® 16k/8k CXP Color
49
e2v semiconductors SAS 2014
Feature Name
CXP @
Size
bytes
Bit field Description
By default
CounterTriggerActivation
[26-24] Select the type of activation for the trigger to start (reset)
the counter :
0: RisingEdge
1: FallingEdge
2: AnyEdge,
3: LevelHigh
4: LevelLow
RisingEdge
CounterEventSource
[23-19] Select the event that will be the source to increment the
counter :
0: Off
9: ExposureStart
10: ExposureEnd
11: Line0
12: Line1
13: Line2
16: Counter1End
17: Counter2End
18: Timer1End
19: Timer2End
20: TimeStampTick
21: MissedTrigger
Off
CounterEventActivation
[18-16]
Select the type of activation for the event that increment
the counter :
0: RisingEdge
1: FallingEdge
2: AnyEdge,
3: LevelHigh
4: LevelLow
RisingEdge
CounterStatus
[15-13]
Get counter status :
0: CounterIdle
1: CounterTriggerWait
2: CounterActive,
3: CounterCompleted
4: CounterOverflow
CounterDuration
0x084B4
4
[31-0]
Set the counter duration (or number of events) before
CounterEnd event is generated
100
CounterReset
0x084B8
4
Reset the selected counter
CounterValue
0x084BC
4
[31-0]
Read the current value of the selected counter
CounterValueAtReset
0x084C0
4
[31-0]
Read the value of the selected counter, when the counter
was reset by a trigger or by an explicit CounterReset.
CounterResetSource
0x084C4
4
[31-27]
Select the signal that reset the counter:
0: Off
1: Software
2: Line0,
3: Line1
4: Line2
CounterResetActivation
[26-24] Select the type of activation for the counter reset source :
0: RisingEdge
1: FallingEdge
2: AnyEdge,
3: LevelHigh
4: LevelLow
RisingEdge
CounterSelector = Counter2
CounterTriggerSource
0x084D0
4
Same as above
CounterTriggerActivation
Same as above
CounterEventSource
Same as above
CounterEventActivation
Same as above
CounterStatus
Same as above
CounterDuration
0x084D4
4
Same as above
CounterReset
0x084D8
4
Same as above
CounterValue
0x084DC
4
Same as above
CounterValueAtReset
0x084E0
4
Same as above
CounterResetSource
0x084E4
4
Same as above
CounterResetActivation
Same as above