® 16k/8k CXP Color
48
e2v semiconductors SAS 2014
12.6
Digital IO Control
Feature Name
CXP @
Size
bytes
Bit field Description
By default
LineStatusAll
0x08460
4
Return the current status of all lines (bit0 for Line0, bit1
for Line1, bit2 for Line2)
LineSelector
Not a register
Select which physical line of the external device
connector to configure {Line0, Line1, Line2 }
Line0
LineSelector = Line0
LineMode
0x08470
4
[31]
Define the physical line as input {Input}
0: Input
1: Output
Input
LineInverter
[30]
Define the signal inversion:
0: False
1: True
False
LineDebounceFilter
[29]
Activate debounce filter {True, False}
False
LineStatus
[28]
Return the current status of the selected :
0: False
1: True
LineFormat
[25-24] Select the electrical format of the selected line (line0 or
line1):
0: TTL
1: LVDS
2: RS422
TTL
Off
LineSelector = Line1
LineMode
0x08480
Same as above
LineInverter
Same as above
LineDebounceFilter
Same as above
LineStatus
Same as above
LineFormat
Same as above
LineSelector = Line2
LineMode
0x08490
Same as above
LineInverter
Same as above
LineDebounceFilter
Same as above
LineStatus
Same as above
LineFormat
Same as above
12.7
Counters
Feature Name
CXP @
Size
bytes
Bit field Description
By default
CounterSelector
Not a register
Select which counter to configure {Counter1, Counter2}
Counter1
CounterSelector = Counter1
CounterTriggerSource
0x084B0
4
[31-27]
Select the signal that start (reset) the counter:
0: Off
9: ExposureStart
10: ExposureEnd
11: Line0
12: Line1
13: Line2
16: Counter1End
17: Counter2End
18: Timer1End
19: Timer2End