warning signals

Hazardous (Classified) Location

Class I, Division 1, Groups A, B, C, D

Class I, Zone 0, Groups IIA, IIB, IIC 

IS-mC1 Sounder Section
IS Class I, Zone 0, AEx ia IIC T4
(

40

°

 T

a

 

 

+

 60

°

C)

Entity Parameters:

      Terminals 

+

 w.r.t. 

      U

i

 = 28V

      I

i

 = 93mA

      P

i

 = 660mW

      C

i

 = 0

     L

i

 = 0

      Terminals 
      S2 & S3 w.r.t. -
      U

i

 = 28V

      I

i

 = 0

      Ci = 0
      Uo = 16.8V
      Io = 7.3mA
      Po = 31mW

 Unclassified Location

Associated Apparatus - Shunt Zener Diode 

Barrier with Entity Parameters:
U

o

 

 28V

I

o

 

 93mA

P

o

 

 660mW

C

o

 

 C

cable

 

(see note 10)

L

o

 

 L

cable

Associated Apparatus - Diode Return Barrier 
with Entity Parameters:

U

o

 

 28V

I

o

 = 0

C

o

 

 C

cable

Associated Apparatus - Diode Return Barrier 
with Entity Parameters:

U

o

 

 28V

I

o

 = 0

C

o

 

 C

cable

+

-

S2

S3

1. No revision to drawing without prior FM approval.

2. The associated apparatus must be FM approved.

3. The associated apparatus manufacturer's installation drawing must 
be followed when installing this equipment.

4. Installation should be in accordance with ANSI/ISA RP12.06.01 
"Installation of Intrinsically Safe Systems for Hazardous (Classified) 

Locations" and the National Electrical Code (ANSI/NFPA 70).

5. The resistance between the intrinsically safe ground and the earth 
ground must be less the 1 ohm.

6. The Shunt Zener Diode Barrier

 

must be a FM approved, resistively 

limited, single channel barrier having parameters less than, or equal 

to, those quoted, and for which the output is non-ignition capable for 
the Class, Division or Zone and Group of use.

7. The IS-mC1 Combined Unit enclosure has an ingress protection 
rating of IP 65. If supplied without cable entry devices then metallic or 
plastic cable glands, or conduit hubs, shall be fitted that provide the 
required environmental protection.

8. To prevent ignition of flammable or combustible atmospheres, 
disconnect power before servicing.

9. Substitution of components may impair safety.

10. The total capacitance connected to ter/- of the sounder, 
i.e. C

cable

 plus any other capacitance, shall not exceed 83nF.

11. If the sounder and /- supply terminals are connected 
internally then the wiring used for such a connection shall have a 
minimum radial thickness of insulation of 0.5mm.

Notes:

CAUTION - Bonding between conduit connections is not automatic 
and must be provided as part of this installation.

CAUTION - The clearance between sounder terminals S2 and S3 is 
less than 6mm.

Drawing No.

Computer Ref.

IS-mC1 Combined 

SOUNDER / BEACON

Control Drawing for shunt zener 
diode barrier / diode return barrier.

Title

21-04-06

-

+

IS-mC1 Beacon Section
IS Class I, Zone 0 AEx ia IIC T4
(

40

°

 T

a

 

 

+

 60

°

C)

Entity Parameters:

Terminals 

+

 w.r.t. 

U

i

 = 28V

Ii = 660mA
P

i

 = 1.2W

C

i

 = 0

L

i

 = 0

+

-

NOTE: 

THE BEACON SECTION CAN BE CONNECTED 
TO IT'S OWN BARRIER INDEPENDENT OF THE 
SOUNDER SECTION. THE REQUIREMENTS OF 
CONTROL DRAWING D5036 SHEET 1 CAN THEN 
BE APPLIED TO THE BEACON SECTION. IF THIS 
OPTION IS USED, THE INTERNAL LINKS 
BETWEEN THE SOUNDER SECTION AND 
BEACON SECTION MUST NOT BE FITTED.

(S

ee 

N

ote

 11)

SCHEDULE DRAWING

No modification permitted

without reference to the

"Notified Body"

Содержание Minialert IS-mC1

Страница 1: ...but at supply voltages above 16V the internal current limit will function and therefore it is recommended that they are not operated continuously with a direct supply greater than 16V IS mC1 Sounder S...

Страница 2: ...e that the equipment is not installed in a location where it may be subjected to external conditions that might cause a build up of electrostatic charges on non conducting surfaces additionally cleani...

Страница 3: ...nd remove the sounder beacon section from the base by turning it anti clockwise Ensure that the O ring seal remains in place b Remove the required 20mm knockout section s depending on system wiring an...

Страница 4: ...meet the requirements for the sounder section see section 4 3 Hazardous Area IS mC1 Beacon IS mC1 Sounder 0V Power Supply Safe Area Barrier On Off 28V 93mA Positive Fig 7 Combined Unit wired for simu...

Страница 5: ...Intermittent 800Hz 0 25s ON 1s OFF Alternating 544Hz 100ms 440Hz 400ms NFS 32 001 Motor Siren Slow rise to 1200Hz Motor Siren Slow rise to 800Hz Continuous 1200Hz Motor Siren Slow rise to 2400Hz Inte...

Страница 6: ...rictive but care should be taken not to exceed a capacitive limit of 83nF for installations when very long cables are used 9 Volume Control The output level of the IS mC1 Combined Sounder Beacon can b...

Страница 7: ...ounder Terminal w r t Sounder Terminal from a barrier having a maximum open circuit voltage Uo that is 28V and a maximum short circuit current Io that is 93mA where Io is resistively limited If not al...

Страница 8: ...uoted and for which the output is non ignition capable for the Class Division or Zone and Group of use 7 The IS mC1 Combined Unit enclosure has an ingress protection rating of IP 65 If supplied withou...

Страница 9: ...ospheres disconnect power before servicing 8 Substitution of components may impair safety 9 The total capacitance connected to terminals of the sounder i e Ccable plus any other capacitance shall not...

Страница 10: ...2018 EN 60079 11 2012 IEC 60079 26 2014 Regulation EU No 305 2011 Construction Products Regulation CPR IS mA1 tones 2 3 9 15 16 17 only Notified Product Certification Body for Certificate of Constanc...

Страница 11: ...and Place of Issue London 23 12 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Страница 12: ...EU No 305 2011 Construction Products Regulation CPR IS mA1 tones 2 3 9 15 16 17 only Notified Product Certification Body for Certificate of Constancy of Performance or EC Type Examination Certificate...

Страница 13: ...and Place of Issue London 04 02 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Отзывы: