Document No. D209-00-511-IS-SC           Issue C          13-06-17                         Sheet 3 of 8

 

large bracket adjustment screws on the side of the unit must 
be  fully  tightened  to  ensure  that  the  unit  cannot  move  in 
service. 

 

 

Fig. 1a Fixing Location for Combined Sounder Beacon Flare 

 

 

Fig. 1b Fixing Location for Combined Sounder Beacon Radial 

 

5)  Access to the Enclosure

 

 

 

 

To access the enclosure, remove the four M4 posi pan head 
screws, M4 spring and plain washers and withdraw the cover.  

 

 

Fig. 2 Accessing the Enclosure. 

 

To  replace  cover,  c

heck  that  the  ‘O’  ring  seal  is  in  place. 

Carefully push the cover in place. Insert and tighten down M4 
screws,  spring  and  plain  washers  in  the  order  shown  above 
and tighten down. 

6)  Selection of Cable, Cable Glands, Blanking 

Elements & Adapters

 

 

When  selecting  the  cable  size,  consideration  must  be  given 
to  the  input  current  that  each  unit  draws  (see  Table  1),  the 
number  of  sounders  on  the  line  and  the  length  of  the  cable 
runs.  The  cable  size  selected  must  have  the  necessary 
capacity  to  provide  the  input  current  to  all  of  the  sounders 
connected to the line.  

 

The  dual  entries  can  be  ordered  with  one  of  the  following 
options: 
 
2-off M20 x 1.5 thread 
2-

off ½” NPT thread 

1-off M20 x 1.5 & 1-

off ½” NPT thread 

 
To  maintain  the  ingress  protection  rating  and  mode  of 
protection, the cable entries must be fitted with suitably rated, 
certified  cable  entry  and/or  blanking  devices  during 
installation.  If  conduit  is  used  for  installation,  seal  conduit 
within 18 inches from the enclosure. 
 
For  ambient  temperatures  over  +40ºC  the  cable  entry 
temperature  may  exceed  +70ºC  or  the  cable  branching 
temperature  may  exceed  +80ºC.  Therefore  suitable  heat 
resisting cables and cable glands must be used as per table 
below 
 

Ambient Temp. 

40ºC 

45ºC 

50ºC 

55ºC 

Min. Rating of cables 
and cable glands 

90ºC 

95ºC 

100ºC 

105ºC 

 

If  a  high  IP  (Ingress  Protection)  rating  is  required  then  a 
suitable sealing washer must be fitted under the cable glands 
or blanking plugs.  

 

For  use  in  explosive  dust  atmospheres,  a  minimum  ingress 
protection rating of IP6X must be maintained. 
 
For  use  in  explosive  gas  atmospheres,  a  minimum  ingress 
protection rating of IP54 must be maintained. 

 

7)  Cable Connections 

 
The  E2xC1LD2  combined  sounder  beacon  has  separate 
printed  circuit  boards  in  the  sounder  and  beacon  sections. 
The terminals for the sounder are on the printed circuit board 
in  the  sounder  section  and  the  terminals  for  the  beacon  are 
on the printed circuit board in the beacon section (see figures 
4a, 4b, 6a and 6b). See section 5 of this manual for access to 
the  enclosure.  See  section  9  and  10  for  AC  and  DC  wiring 
diagrams respectively. Electrical connections are to be made 
into  the  terminal  blocks  on  the  PCBA  located  in  the 
enclosure.  See  section  5  of  this  manual  for  access  to  the 
enclosure.  

 

Wires  having  a  cross  sectional  area  between  0.5  mm²  to 
2.5mm²  can  be  connected  to  each  terminal  way.  If  an  input 
and  output  wire  is  required  the  2-off  Live/Neutral  or  +/- 
terminals  can  be  used.  If  fitting  2-off  wires  to  one  terminal 
way  the  sum  of  the  2-off  wires  must  be  a  maximum  cross 
sectional area of 2.5mm². Strip wires to 8mm. Wires may also 
be  fitted  using  ferrules.  Terminal  screws  on  the  sounder 
PCBA need to be tightened down with a  tightening torque of 
0.45  Nm  /  4  Lb-in.  Terminal  screws  on  the  beacon  PCBA 
need  to  be  tightened  down  with  a  tightening  torque  of  0.56 
Nm  /  5  Lb-in.  When  connecting  wires  to  the  terminals  great 

Warning 

 

Hot surfaces. External surfaces 

and internal components may be hot after 
operation, take care when handling the 
equipment. 

Warning 

– High voltage may be present, 

risk of electric shock. DO NOT open when 
energised, disconnect power before 
opening. 

(Appropriate cable entry devices 
to be customer supplied)  

Beacon 
Housing  

M4 Cover 
Screw 

M4 Spring 
Washer 

M4 Plain 
Washer 

Sounder 
Housing  

Содержание E2 C1LD2F Series

Страница 1: ...rtificate No DEMKO 06ATEX 0421554X IECEx ULD 14 0012X The E2xC1LD2 combined alarm horn and LED beacon is rated as follows CE Marking Zones Gas Dust Groups and Temperature Classification When connected...

Страница 2: ...24 18 30Vdc 346mA 284mA E2xC1LD2FDC048 E2xC1LD2RDC048 42 54Vdc 115mA 146mA E2xC1LD2FAC115 E2xC1LD2RAC115 115 120Vac 50 60Hz 102 4mA 104mA E2xC1LD2FAC230 E2xC1LD2RAC230 220 230Vac 50 60Hz 49 4mA 54mA I...

Страница 3: ...s and cable glands must be used as per table below Ambient Temp 40 C 45 C 50 C 55 C Min Rating of cables and cable glands 90 C 95 C 100 C 105 C If a high IP Ingress Protection rating is required then...

Страница 4: ...d be removed from both sets of terminal blocks refer to fig 3b 5b 9 AC Wiring A 6 way terminal block is provided on the AC Sounder for power There are 2 off Live 2 off Neutral and 2 off Earth terminal...

Страница 5: ...here are 2 off ve 2 off ve 1 off stage2 and 1 off stage 3 terminals in total 10 1 Wiring Diagrams Fig 5a E2xC1LD2 DC Simplified Block Diagram for Simultaneous Beacon Sounder Operation Pre wired Connec...

Страница 6: ...e resistor legs as shown in Fig 9a remove the ve and ve terminal plugs and fit the resistor across the two terminal plugs before refitting them to the PCBA as shown in Fig 9b A spacing of at least 1 1...

Страница 7: ...and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 19 IEC60079 19 Explosive atmospheres Equipment repai...

Страница 8: ...1 1 0 554Hz Continuous 27 Tone 15 Tone 2 1 0 0 1 1 0 Bell 26 Tone 5 Tone 29 0 0 0 1 1 0 2400 2900Hz 50Hz Sweeping 25 Tone 5 Tone 29 1 1 1 0 1 0 800 1000Hz 50Hz Sweeping 24 Tone 5 Tone 6 0 1 1 0 1 0 8...

Страница 9: ......

Отзывы: