2.2 NEC Class / Zone ratings US 

 
The  E2xC1LD2  combined  alarm  horn  and  LED  beacon 
complies with the following standards: 
 

UL 60079-0-2013 
UL 60079-15-2013 
UL 60079-31-2015 

 
The  E2xC1LD2  combined  alarm  horn  and  LED  beacon  is 
rated as follows: 
 
Class I Zone 2 AEx nA IIC Gc T3 Ta -20°C to +55°C 
Zone 22 AEx tc IIIC Dc T105°C Ta -20°C to +55°C 
Zone 22 AEx tc IIIC Dc T90°C Ta -20°C to +55°C 
 
Installation must be carried out in compliance with the 
National Electric Code. 
 

2.3 CEC Class / Zone ratings Canada 

 
The  E2xC1LD2  combined  alarm  horn  and  LED  beacon 
complies with the following standards: 
 

CAN/CSA C22.2 No. 60079-0:2015 
CAN/CSA C22.2 No. 60079-15:2016 
CAN/CSA C22.2 No. 60079-31:2015 

 
The  E2xC1LD2  combined  alarm  horn  and  LED  beacon  is 
rated as follows: 
 
Ex nA IIC Gc T3B Ta -20°C to +55°C 
Ex nA IIC Gc T3C Ta -20°C to +40°C 
Ex tc IIIC Dc T105°C Ta -20°C to +55°C 
Ex tc IIIC Dc T90°C Ta -20°C to +40°C 
 
Installation must be carried out in compliance with the 
Canadian Electric Code 
 

2.4 NEC & CEC Class / Division Ratings for US / Canada 

 
The  E2xC1LD2  combined  alarm  horn  and  LED  beacon 
complies with the following standards: 
 

ANSI/ISA 12.12.01-2015 
CSA C22.2 No. 213-16 

 
The  E2xC1LD2  combined  alarm  horn  and  LED  beacon  is 
rated as follows: 
 
Class I, Div 2, ABCD T3C Ta -20°C to +55°C 
Class II, Div 2, FG T4A Ta -20°C to +55°C 
Class II, Div 2, FG T5 Ta -20°C to +40°C 
Class III, Div 1&2 Ta -20°C to +55°C 
 
Installation must be carried out in compliance with the 
National Electric Code / Canadian Electric Code 
 

2.5 Ingress Protection Ratings 

 
The product is rated for ingress Protection as follows: 
 

IP rating per EN60079-0:   

IP64 

 

IP rating per EN60529: 

 

IP66 

 

Type rating per UL50E / NEMA250: 4 / 4X / 13 

 To maintain the ingress protection rating, the two off cable 
entries must be fitted with suitably rated, certified cable entry 
and/or blanking devices during installation. 
 

2.6 Electrical Ratings 

 

Part No. 

Voltage 

Beacon 
Current 

Sounder 

Current 

E2xC1LD2FDC024 / 
E2xC1LD2RDC024 

18-30Vdc 

346mA 

284mA 

E2xC1LD2FDC048 / 
E2xC1LD2RDC048 

42-54Vdc 

115mA 

146mA 

E2xC1LD2FAC115 / 
E2xC1LD2RAC115 

115-120Vac 
50/60Hz 

102.4mA 

104mA 

E2xC1LD2FAC230 / 
E2xC1LD2RAC230 

220-230Vac 
50/60Hz 

49.4mA 

54mA 

   

It is important that a suitable power supply is used to run the 
equipment.  The  power  supply  selected  must  have  the 
necessary  capacity  to  provide  the  input  current  to  all  the 
units. 

 

The input current will vary according to the voltage input level 
and  the  frequency  of  the  tone  selected.  The  current  levels 
shown  above  are  for  the  tone  resulting  in  max.  current draw 
(tone  1  -  340Hz  Continuous)  and  worst-case  input  voltage 
producing max. current. 

 

3)  Special Conditions of Use 

 

When  used  for  a  Group  III  application,  the  surface  of  the 
enclosure  may  store  electrostatic  charge  and  become  a 
source  of  ignition  in  applications  with  a  low  relative  humidity 
<~30% relative humidity where the surface is relatively free of 
surface contamination such as dirt, dust, or oil. 
 
Guidance  on  protection  against  the  risk  of  ignition  due  to 
electrostatic discharge can be found in EN TR50404 and IEC 
TR60079-32. 

 

End  user shall adhere  to  the manufacturer’s installation  and 
instruction  when  performing  housekeeping  to  avoid  the 
potential for hazardous electrostatic charges during cleaning, 
by using a damp cloth. 
 
To  maintain  the  ingress  protection  rating  and  mode  of 
protection, the cable entries must be fitted with suitably rated, 
certified  cable  entry  and/or  blanking  devices  during 
installation.  If  conduit  is  used  for  installation,  seal  conduit 
within 18 inches from the enclosure. 
 
Equipment  with  the  flare  horn  shall  not  be  installed  with  the 
flare higher than horizontal (to avoid accumulation of dust). 
 
The  equipment  incorporates  metal  parts  isolated  from  earth, 
having  capacitance  values  exceeding  the  limits  permitted  in 
the  standards  of  certification.  Mounting  bracket 

–  10.33pF; 

Lens guard 

– 12.33pF. 

 

4)  Location and Mounting

 

 

The  location  of  the  unit  should  be  made  with  due  regard  to 
the area over which the warning signal must be audible. They 
should  only  be  fixed  to  services  that  can  carry  the  weight  of 
the unit. 

 

The E2x combined sounder beacon should be secured to any 
flat surface using the three 7mm fixing holes on the stainless 
steel U shaped mounting bracket. See Figure 1. The required 
angle  can  be  achieved  by  loosening  the  two  large  bracket 
screws  in  the  side  of  the unit,  which  allow  adjustment  of  the 
unit in steps of 18°. On completion of the installation the two 

Содержание E2 C1LD2F Series

Страница 1: ...rtificate No DEMKO 06ATEX 0421554X IECEx ULD 14 0012X The E2xC1LD2 combined alarm horn and LED beacon is rated as follows CE Marking Zones Gas Dust Groups and Temperature Classification When connected...

Страница 2: ...24 18 30Vdc 346mA 284mA E2xC1LD2FDC048 E2xC1LD2RDC048 42 54Vdc 115mA 146mA E2xC1LD2FAC115 E2xC1LD2RAC115 115 120Vac 50 60Hz 102 4mA 104mA E2xC1LD2FAC230 E2xC1LD2RAC230 220 230Vac 50 60Hz 49 4mA 54mA I...

Страница 3: ...s and cable glands must be used as per table below Ambient Temp 40 C 45 C 50 C 55 C Min Rating of cables and cable glands 90 C 95 C 100 C 105 C If a high IP Ingress Protection rating is required then...

Страница 4: ...d be removed from both sets of terminal blocks refer to fig 3b 5b 9 AC Wiring A 6 way terminal block is provided on the AC Sounder for power There are 2 off Live 2 off Neutral and 2 off Earth terminal...

Страница 5: ...here are 2 off ve 2 off ve 1 off stage2 and 1 off stage 3 terminals in total 10 1 Wiring Diagrams Fig 5a E2xC1LD2 DC Simplified Block Diagram for Simultaneous Beacon Sounder Operation Pre wired Connec...

Страница 6: ...e resistor legs as shown in Fig 9a remove the ve and ve terminal plugs and fit the resistor across the two terminal plugs before refitting them to the PCBA as shown in Fig 9b A spacing of at least 1 1...

Страница 7: ...and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN60079 19 IEC60079 19 Explosive atmospheres Equipment repai...

Страница 8: ...1 1 0 554Hz Continuous 27 Tone 15 Tone 2 1 0 0 1 1 0 Bell 26 Tone 5 Tone 29 0 0 0 1 1 0 2400 2900Hz 50Hz Sweeping 25 Tone 5 Tone 29 1 1 1 0 1 0 800 1000Hz 50Hz Sweeping 24 Tone 5 Tone 6 0 1 1 0 1 0 8...

Страница 9: ......

Отзывы: