E2S Telephone: +44 (0)20 8743 8880 Fax: +44 (0)20 8740 4200 Email: [email protected] 

www.e2s.com 

DC-102_Issue_A - Page 1 of 2 - QAF_252_Issue_5

 

UKCA Declaration of Conformity 

Manufacturer:   

 

European Safety Systems Ltd. 

 

 

 

Impress House, Mansell Road, Acton 

 

 

 

London, W3 7QH 

 

 

 

United Kingdom 

 

Equipment Type:  

 

D2xS1, D2xC1X05, D2xC1X10 

 

 

 

D2xB1X05, D2xB1X10, D2xB1LD2, D2xB1XH1, D2xB1XH2, D2xB1LD3 

 

 

 

D2xC2X05, D2xC2X10, D2xC2LD2, D2xC2XH1, D2xC2XH2, D2xC2LD3 

 

 

 

D2xJ1

 

 

Directive  UKSI 2016:1107 (as amended by UKSI 2019:696) – Schedule 3A, Part 1 : Product or Protective System Intended for use in Potentially Explosive Atmospheres   
(UKCA) 

 

Notified Body for UK type Examination (Module B): 

UL International (UK) Ltd 
Notified Body No.: 0843 

Unit 1‐3 Horizon Kingsland Business Park, Wade Road, 

Basingstoke, Hampshire RG24 8AH UK 

UK‐type Examination Certificate (Module B): 

UL21UKEX2131X 

Notified Body for Quality Assurance Notification / Conformity to EU‐type 

based on 
quality assurance of the production process (Module D): 

Sira Certification Service 

Notified Body No.: 0518 
Rake Lane, Eccleston, Chester CH4 9JN, UK 

Quality Assurance Notification (Module D): 

CSAE 22UKQAN0046 

Provisions fulfilled by the equipment: 

II 3G Ex ec IIC T6/T4/T3/T2/T1 Gc 

II 3D Ex tc IIIC Ex tc IIIC T55/75/80/85/90/95/105/110°C Dc 

IP66 Ingress / Dust Protection to EN60079‐0 / EN60079‐31 

Standards applied: 

EN IEC 60079‐0:2018  
EN IEC 60079‐7:2015 +A1:2018 

EN 60079‐31:2014 

Directive 2014/30/EU: Electromagnetic Compatibility Directive (EMC)  

Standards applied: 

 

 

EN 61000‐6‐1:2007 
EN 61000‐6‐2:2005 

EN 61000‐6‐3:2007 / A1:2011 / AC: 2012 

EN 61000‐6‐4:2007 / A1: 2011 

Directive 2011/65/EU: Restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS) 
The product and all the components contained within it are in accordance with the restriction of the use of hazardous substances in electrical and electronic 
equipment, including amendment by Directive 2015/863/EU.

 

Regulation (EC) 1907/2006: Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) 

The product and all the components contained within it are free from substances of very high concern. 

Other Standards and Regulations 

EN 60529:1992+A2:2013 ‐ Degrees of protection provided by enclosures (IP code) – enclosure rated IP66 

 

 

 

Содержание D2xC2LD2 Series

Страница 1: ...38 For use in public mode the beacon must be without the wire guard or plastic lens cover See fire instruction manual D211 00 611 IS SC UL 3 2 ATEX IECEx UKEx certification Standards EN IEC 60079 0 20...

Страница 2: ...lassification Area Classification Zone 2 Explosive gas air mixture not likely to occur in normal operation and if it does it will only exist for a short time Zone 22 Explosive dust air mixture not lik...

Страница 3: ...the area over which the warning signal must be visible and audible It should only be fixed to services that can carry the weight of the unit DxC2 Alarm Horn and Strobe to a flat surface via the two 9...

Страница 4: ...used If fitting 2 off wires to one terminal way the sum of the 2 off wires must be a maximum cross sectional area of 2 5mm Strip wires to 8mm Wires may also be fitted using ferrules Terminal screws n...

Страница 5: ...ove the ve and ve terminal plugs and fit the resistor across the two terminal plugs before refitting them to the PCBA as shown in Fig 8 A spacing of at least 1 16 1 58mm must be provided through air a...

Страница 6: ...re Alarm units cannot be used with a lens or a guard To change the lens cover unscrew the 4 off M5 posi pan head screws spring and flat washers using a screwdriver Remove the wire guard and replace th...

Страница 7: ...Triple Strike 144 8mA 211 2mA D2xC2LD2DC048 48Vdc 48Vdc Steady High Power 115mA 181mA 115mA 218mA Steady Low Power 62 4mA 62 4mA Flashing 1Hz 47 4mA 47 4mA Flashing 1 33Hz 50 3mA 50 3mA Flashing 2Hz 5...

Страница 8: ...s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 1 1 0 1 0 0 44 1 8 13 422 775Hz 0 85 on 0 5 off x3 1s gap NFPA Temporal Coded 0 0 1 1 0 0 44 1 8 14 1000 2000Hz 1Hz Singapore 1 0 1 1 0 0 23 3 35 15 3...

Страница 9: ...Hz Sweeping 1 0 0 0 1 1 44 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 44 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0 1 1 64 24 12 53 800 1000Hz 1Hz Sweeping 0 0 1 0 1 1 56 24 12 54 800 1000Hz 7Hz S...

Страница 10: ...ol section For fire alarm use the temporal pattern tone No 12 as per the tone table provided in these instructions must be selected This tone produces a minimum sound pressure level of CAN ULC S525 10...

Страница 11: ...75 Fig 1 Horizontal dispersion angles for wall mounting Table 1 Horizontal Light Output Dispersion for Wall Mounting Viewing Angle Of Rating Intensity cd at 1Hz flash rate Intensity cd at 1 33Hz flash...

Страница 12: ...ting public mode 75 60 45 30 15 0 90 Fig 2 Vertical dispersion angles for wall mounting Table 2 Vertical Light Output Dispersion for Wall Mounting Viewing Angle Of Rating Intensity cd at 1Hz flash rat...

Страница 13: ...CAN ULC S526 at worst case min input voltage 3 4 On axis light output rating private mode Table 3 Vertical Light Output Dispersion for Ceiling Mounting Viewing Angle Of Rating Intensity cd at 1Hz fla...

Страница 14: ...s Model Nom Voltage Voltage Range Flash Rate Setting Init Peak Surge Current A Init RMS Surge Current mA D2xC2LD2DC024 24Vdc Regulated 24 16 33Vdc 1Hz 60fpm 2 73 240 1 33Hz 80 fpm 2 75 214 2Hz 120fpm...

Страница 15: ...3 to ve AC D2XC2LD2 UNITS Power Live Neutral Stage 1 Apply power to Sounder L N Stage 2 Apply power to Sounder L N Connect Stage 2 to Common Stage 3 Apply power to Sounder L N Connect Stage 3 to Commo...

Страница 16: ...herlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc I...

Страница 17: ...e and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Страница 18: ...Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc IIIC Ex tc IIIC T55 75 80...

Страница 19: ...Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the marke...

Отзывы: