ALL DIMENSIONS IN MM

IF IN DOUBT, ASK - 
DO NOT SCALE

2S

warning signals

NTS

D2xC2LD2 PUBLIC MODE FIRE/GENERAL SIGNALING
COMBINED BEACON AND SOUNDER WIRING DIAGRAM

D211-06-611

1

1

OF

R.N.POTTS

R.S. RAIT

B. ISARD

27-06-2019

27-06-2019

27-06-2019

MOD No.

REASON - INITIAL - DATE

ISSUE

1

INTRODUCTION
RSR 02-01-2020

D2x

-
-

-

+

+

+

E
E

+ve IN

+ve OUT

-ve IN

-ve OUT

EARTH IN

EARTH OUT

DC D2XC2LD2 UNITS
Line Monitoring

Stage 1: Apply power to Sve & -ve
Stage 2: Apply power to Sve & -ve. Connect Stage 2 to -ve
Stage 3: Apply power to Sve & -ve. Connect Stage 3 to -ve
Stage 4: Apply power to Sve & -ve. Connect Stage 2 and Stage 3 to -ve

AC D2XC2LD2 UNITS

Power: Live & Neutral

Stage 1: Apply power to Sounder L & N
Stage 2: Apply power to Sounder L & N. Connect Stage 2 to Common
Stage 3: Apply power to Sounder L & N. Connect Stage 3 to Common
Stage 4: Apply power to Sounder L & N. Connect Stage 2 and Stage 3 to Common

OPTIONAL LINE MONITORING RESISTOR, CUSTOMER SUPPLIED,  
REQUIRED MINIMUM VALUES:

R

1

 24VDC : 1KΩ MIN, 2W MIN OR 3K9Ω MIN, 0.5W MIN
 48VDC : 3.9KΩ MIN, 2W MIN OR 15KΩ MIN, 0.5W MIN

N
N

N

L

L

L

C
S2
S3
E
E

LIVE IN

LIVE OUT

NEUTRAL IN

NEUTRAL OUT

COMMON

STAGE 2
STAGE 3

EARTH IN

EARTH OUT

S3

S2

STAGE 3

STAGE 2

R

1

R

1

WIRING LINKING BEACON & SOUNDER
FACTORY FITTED

TO OPERATE SOUNDER AND BEACON 

INDEPENDENTLY, REMOVE FACTORY 
FITTED WIRES LINKING THE UNITS

-
-

+

+

-ve OUT

S3

S2

+ve OUT

NEUTRAL OUT

LIVE OUT

EARTH IN

EARTH OUT

N
N

L

L

E

E

2

UPDATED FORMAT
DH 17-05-2022

Содержание D2xC2LD2 Series

Страница 1: ...38 For use in public mode the beacon must be without the wire guard or plastic lens cover See fire instruction manual D211 00 611 IS SC UL 3 2 ATEX IECEx UKEx certification Standards EN IEC 60079 0 20...

Страница 2: ...lassification Area Classification Zone 2 Explosive gas air mixture not likely to occur in normal operation and if it does it will only exist for a short time Zone 22 Explosive dust air mixture not lik...

Страница 3: ...the area over which the warning signal must be visible and audible It should only be fixed to services that can carry the weight of the unit DxC2 Alarm Horn and Strobe to a flat surface via the two 9...

Страница 4: ...used If fitting 2 off wires to one terminal way the sum of the 2 off wires must be a maximum cross sectional area of 2 5mm Strip wires to 8mm Wires may also be fitted using ferrules Terminal screws n...

Страница 5: ...ove the ve and ve terminal plugs and fit the resistor across the two terminal plugs before refitting them to the PCBA as shown in Fig 8 A spacing of at least 1 16 1 58mm must be provided through air a...

Страница 6: ...re Alarm units cannot be used with a lens or a guard To change the lens cover unscrew the 4 off M5 posi pan head screws spring and flat washers using a screwdriver Remove the wire guard and replace th...

Страница 7: ...Triple Strike 144 8mA 211 2mA D2xC2LD2DC048 48Vdc 48Vdc Steady High Power 115mA 181mA 115mA 218mA Steady Low Power 62 4mA 62 4mA Flashing 1Hz 47 4mA 47 4mA Flashing 1 33Hz 50 3mA 50 3mA Flashing 2Hz 5...

Страница 8: ...s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 1 1 0 1 0 0 44 1 8 13 422 775Hz 0 85 on 0 5 off x3 1s gap NFPA Temporal Coded 0 0 1 1 0 0 44 1 8 14 1000 2000Hz 1Hz Singapore 1 0 1 1 0 0 23 3 35 15 3...

Страница 9: ...Hz Sweeping 1 0 0 0 1 1 44 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 44 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0 1 1 64 24 12 53 800 1000Hz 1Hz Sweeping 0 0 1 0 1 1 56 24 12 54 800 1000Hz 7Hz S...

Страница 10: ...ol section For fire alarm use the temporal pattern tone No 12 as per the tone table provided in these instructions must be selected This tone produces a minimum sound pressure level of CAN ULC S525 10...

Страница 11: ...75 Fig 1 Horizontal dispersion angles for wall mounting Table 1 Horizontal Light Output Dispersion for Wall Mounting Viewing Angle Of Rating Intensity cd at 1Hz flash rate Intensity cd at 1 33Hz flash...

Страница 12: ...ting public mode 75 60 45 30 15 0 90 Fig 2 Vertical dispersion angles for wall mounting Table 2 Vertical Light Output Dispersion for Wall Mounting Viewing Angle Of Rating Intensity cd at 1Hz flash rat...

Страница 13: ...CAN ULC S526 at worst case min input voltage 3 4 On axis light output rating private mode Table 3 Vertical Light Output Dispersion for Ceiling Mounting Viewing Angle Of Rating Intensity cd at 1Hz fla...

Страница 14: ...s Model Nom Voltage Voltage Range Flash Rate Setting Init Peak Surge Current A Init RMS Surge Current mA D2xC2LD2DC024 24Vdc Regulated 24 16 33Vdc 1Hz 60fpm 2 73 240 1 33Hz 80 fpm 2 75 214 2Hz 120fpm...

Страница 15: ...3 to ve AC D2XC2LD2 UNITS Power Live Neutral Stage 1 Apply power to Sounder L N Stage 2 Apply power to Sounder L N Connect Stage 2 to Common Stage 3 Apply power to Sounder L N Connect Stage 3 to Commo...

Страница 16: ...herlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc I...

Страница 17: ...e and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Страница 18: ...Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc IIIC Ex tc IIIC T55 75 80...

Страница 19: ...Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the marke...

Отзывы: