E2S D2xC2LD2 Series Скачать руководство пользователя страница 8

 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH

 

www.e2s.com

 

Tel: +44 (0)208 743 8880

 

Document No. D211-00-611-IS

 

Issue 1

 

20-08-22

 

 

Sheet 8 of 9

 

 

1600Hz

1400Hz

1s

0.5s

17) Tone Table 

Tone Selection

 

– 

To select the required first stage tone set the tone switches 1 to 6 (see Fig 2) to the tone setting shown in the table below. The table also shows 

which 2

nd

, 3

rd

 and 4

th

 stage tones are available for use with the selected first stage tone if more than one tone output stage is required.

 

Stage 1 

Tone No 

Tone Description 

Tone Visual 

Switch Settings 

1 2 3 4 5 6

 

Stage 2 

Tone 

(S2) 

Stage 3 

Tone 

(S3) 

Stage 4 

Tone 

(S2 + S3) 

1000Hz PFEER Toxic Gas 

  

0 0 0 0 0 0 

44 

1200/500Hz @ 1Hz DIN / 
PFEER P.T.A.P. 

  

1 0 0 0 0 0 

44 

1000Hz @ 0.5Hz(1s on, 1s 
off) PFEER Gen. Alarm 

  

0 1 0 0 0 0 

44 

1.4KHz-1.6KHz 1s, 1.6KHz-
1.4KHz 0.5s NF C 48-265 

  

1 1 0 0 0 0 

44 

24 

544Hz(100mS)/440Hz 
(400mS) NF S 32-001 

  

0 0 1 0 0 0 

52 

19 

1500/500Hz - (0.5s on , 0.5s 
off) x3 + 1s gap AS4428 

  

1 0 1 0 0 0 

44 

500-1500Hz Sweeping 2 sec 
on 1 sec off AS4428 

  

0 1 1 0 0 0 

44 

500/1200Hz @ 0.26Hz(3.3s 
on, 0.5s off) Netherlands - 
NEN 2575 

  

1 1 1 0 0 0 

44 

24 

35 

1000Hz (1s on, 1s off)x7 + (7s 
on, 1s off) IMO Code 1a 

  

  

0 0 0 1 0 0 

18 

34 

10 

1000Hz (1s on, 1s off)x7 + (7s 
on, 1s off) IMO Code 1a 

1 0 0 1 0 0 

21 

34 

11 

420Hz(0.5s on, 0.5s off)x3 + 
1s gap ISO 8201 Temporal 
Pattern 

  

0 1 0 1 0 0 

44 

12 

1000Hz(0.5s on, 0.5s off)x3 + 
1s gap ISO 8201 Temporal 
Pattern 

  

1 1 0 1 0 0 

44 

13 

422/775Hz  -  (0.85 on, 0.5 
off) x3 + 1s gap NFPA - 
Temporal Coded 

  

0 0 1 1 0 0 

44 

14 

1000/2000Hz @ 1Hz 
Singapore 

  

1 0 1 1 0 0 

23 

35 

15 

300Hz Continuous 

  

0 1 1 1 0 0 

44 

24 

35 

16 

440Hz Continuous 

  

1 1 1 1 0 0 

44 

24 

35 

17 

470Hz Continuous 

  

0 0 0 0 1 0 

44 

24 

35 

18 

500Hz Continuous IMO code 
2 (Low) 

  

1 0 0 0 1 0 

44 

24 

35 

19 

554Hz Continuous 

  

0 1 0 0 1 0 

64 

24 

35 

20 

660Hz Continuous 

  

1 1 0 0 1 0 

44 

24 

35 

21 

800Hz IMO code 2 (High) 

  

0 0 1 0 1 0 

44 

24 

35 

22 

1200Hz Continuous 

  

1 0 1 0 1 0 

44 

24 

35 

23 

2000Hz Continuous 

  

0 1 1 0 1 0 

15 

35 

24 

2400Hz Continuous 

  

1 1 1 0 1 0 

48 

20 

35 

25 

440 @0.83Hz (50 
cycles/minute) Intermittent 

  

0 0 0 1 1 0  

44 

26 

470 @0.9Hz - 1.1s 
Intermittent 

  

1 0 0 1 1 0 

44 

27 

470Hz @5Hz - (5 
cycles/second) Intermittent 

  

0 1 0 1 1 0 

44 

28 

544Hz @ 1.14Hz - 0.875s 
Intermittent 

  

1 1 0 1 1 0 

44 

24 

29 

655Hz @ 0.875Hz 
Intermittent 

  

0 0 1 1 1 0 

44 

30 

660Hz @0.28Hz - 1.8sec on, 
1.8sec off Intermittent 

  

1 0 1 1 1 0 

44 

24 

31 

660Hz @3.34Hz - 150mS on, 
150mS off

 Intermittent

 

  

0 1 1 1 1 0 

30 

24 

1000Hz

 

1000Hz

1s

1s

544Hz

440Hz

0.1s

0.4s

1500Hz

500Hz

0.5s 0.5s

1.5s

0.5s 0.5s 0.5s

1500Hz

500Hz

2s

1s

1200Hz

500Hz

3.3s

0.5s

1s

1s

1s

7s

7s

1s

1s

1s

1s

1s

1s

1s

1000Hz 1s

1s

1s

1s

0.5s

0.5s

0.5s

1.5s

420Hz 0.5s

0.5s

1000Hz 0.5s

0.5s

0.5s

0.5s

0.5s

1.5s

775Hz

422Hz

0.85s

0.5s

0.85s

0.5s

0.85s

1.5s

2000Hz

1000Hz

1s

300Hz

 

440Hz

 

470Hz

 

500Hz

 

554Hz

 

660Hz

 

800Hz

 

1200Hz

 

2000Hz

 

2400Hz

 

440Hz

0.6s

0.6s

470Hz 0.55s

0.55s

470Hz 0.1s

0.1s

470Hz 0.43s

0.44s

655Hz 0.57s

0.57s

660Hz 1.8s

1.8s

660Hz 0.15s

0.15s

500Hz

1s

1200Hz

 

Содержание D2xC2LD2 Series

Страница 1: ...38 For use in public mode the beacon must be without the wire guard or plastic lens cover See fire instruction manual D211 00 611 IS SC UL 3 2 ATEX IECEx UKEx certification Standards EN IEC 60079 0 20...

Страница 2: ...lassification Area Classification Zone 2 Explosive gas air mixture not likely to occur in normal operation and if it does it will only exist for a short time Zone 22 Explosive dust air mixture not lik...

Страница 3: ...the area over which the warning signal must be visible and audible It should only be fixed to services that can carry the weight of the unit DxC2 Alarm Horn and Strobe to a flat surface via the two 9...

Страница 4: ...used If fitting 2 off wires to one terminal way the sum of the 2 off wires must be a maximum cross sectional area of 2 5mm Strip wires to 8mm Wires may also be fitted using ferrules Terminal screws n...

Страница 5: ...ove the ve and ve terminal plugs and fit the resistor across the two terminal plugs before refitting them to the PCBA as shown in Fig 8 A spacing of at least 1 16 1 58mm must be provided through air a...

Страница 6: ...re Alarm units cannot be used with a lens or a guard To change the lens cover unscrew the 4 off M5 posi pan head screws spring and flat washers using a screwdriver Remove the wire guard and replace th...

Страница 7: ...Triple Strike 144 8mA 211 2mA D2xC2LD2DC048 48Vdc 48Vdc Steady High Power 115mA 181mA 115mA 218mA Steady Low Power 62 4mA 62 4mA Flashing 1Hz 47 4mA 47 4mA Flashing 1 33Hz 50 3mA 50 3mA Flashing 2Hz 5...

Страница 8: ...s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 1 1 0 1 0 0 44 1 8 13 422 775Hz 0 85 on 0 5 off x3 1s gap NFPA Temporal Coded 0 0 1 1 0 0 44 1 8 14 1000 2000Hz 1Hz Singapore 1 0 1 1 0 0 23 3 35 15 3...

Страница 9: ...Hz Sweeping 1 0 0 0 1 1 44 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 44 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0 1 1 64 24 12 53 800 1000Hz 1Hz Sweeping 0 0 1 0 1 1 56 24 12 54 800 1000Hz 7Hz S...

Страница 10: ...ol section For fire alarm use the temporal pattern tone No 12 as per the tone table provided in these instructions must be selected This tone produces a minimum sound pressure level of CAN ULC S525 10...

Страница 11: ...75 Fig 1 Horizontal dispersion angles for wall mounting Table 1 Horizontal Light Output Dispersion for Wall Mounting Viewing Angle Of Rating Intensity cd at 1Hz flash rate Intensity cd at 1 33Hz flash...

Страница 12: ...ting public mode 75 60 45 30 15 0 90 Fig 2 Vertical dispersion angles for wall mounting Table 2 Vertical Light Output Dispersion for Wall Mounting Viewing Angle Of Rating Intensity cd at 1Hz flash rat...

Страница 13: ...CAN ULC S526 at worst case min input voltage 3 4 On axis light output rating private mode Table 3 Vertical Light Output Dispersion for Ceiling Mounting Viewing Angle Of Rating Intensity cd at 1Hz fla...

Страница 14: ...s Model Nom Voltage Voltage Range Flash Rate Setting Init Peak Surge Current A Init RMS Surge Current mA D2xC2LD2DC024 24Vdc Regulated 24 16 33Vdc 1Hz 60fpm 2 73 240 1 33Hz 80 fpm 2 75 214 2Hz 120fpm...

Страница 15: ...3 to ve AC D2XC2LD2 UNITS Power Live Neutral Stage 1 Apply power to Sounder L N Stage 2 Apply power to Sounder L N Connect Stage 2 to Common Stage 3 Apply power to Sounder L N Connect Stage 3 to Commo...

Страница 16: ...herlands B V Utrechtseweg 310 6812 AR Arnhem Netherlands Quality Assurance Notification Module D SIRA 05 ATEX M342 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc I...

Страница 17: ...e and Place of Issue London 22 08 2022 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the m...

Страница 18: ...Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification Module D CSAE 22UKQAN0046 Provisions fulfilled by the equipment II 3G Ex ec IIC T6 T4 T3 T2 T1 Gc II 3D Ex tc IIIC Ex tc IIIC T55 75 80...

Страница 19: ...Place of Issue London 22 08 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the marke...

Отзывы: