European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e-2-s.com             Fax: +44 (0)208 740 4200 
Document No. D189-00-001-IS     Issue:  9                        01-06-16               Sheet 6 of 7 

 

1600Hz

1400Hz

1s

0.5s

Tone Selection

 

– 

To select the required first stage tone set the tone switches 1 to 6 (see Fig 2) to the tone setting shown in the table below. The table also shows 

which 2

nd

, 3

rd

 and 4

th

 stage tones are available for use with the selected first stage tone if more than one tone output stage is required.

 

Stage 1 

Tone No 

Tone Description 

Tone Visual 

Switch Settings 

1 2 3 4 5 6

 

Stage 2 

Tone 

(S2) 

Stage 3 

Tone 

(S3) 

Stage 4 

Tone 

(S2 + S3) 

1000Hz PFEER Toxic Gas 

  

0 0 0 0 0 0 

44 

1200/500Hz @ 1Hz DIN / 
PFEER P.T.A.P. 

  

1 0 0 0 0 0 

44 

1000Hz @ 0.5Hz(1s on, 1s 
off) PFEER Gen. Alarm 

  

0 1 0 0 0 0 

44 

1.4KHz-1.6KHz 1s, 1.6KHz-
1.4KHz 0.5s NF C 48-265 

  

1 1 0 0 0 0 

44 

24 

544Hz(100mS)/440Hz 
(400mS) NF S 32-001 

  

0 0 1 0 0 0 

52 

19 

1500/500Hz - (0.5s on , 0.5s 
off) x3 + 1s gap AS4428 

  

1 0 1 0 0 0 

44 

500-1500Hz Sweeping 2 sec 
on 1 sec off AS4428 

  

0 1 1 0 0 0 

44 

500/1200Hz @ 0.26Hz(3.3s 
on, 0.5s off) Netherlands - 
NEN 2575 

  

1 1 1 0 0 0 

44 

24 

35 

1000Hz (1s on, 1s off)x7 + (7s 
on, 1s off) IMO Code 1a 

  

  

0 0 0 1 0 0 

18 

34 

10 

1000Hz (1s on, 1s off)x7 + (7s 
on, 1s off) IMO Code 1a 

1 0 0 1 0 0 

21 

34 

11 

420Hz(0.5s on, 0.5s off)x3 + 
1s gap ISO 8201 Temporal 
Pattern 

  

0 1 0 1 0 0 

44 

12 

1000Hz(0.5s on, 0.5s off)x3 + 
1s gap ISO 8201 Temporal 
Pattern 

  

1 1 0 1 0 0 

44 

13 

422/775Hz  -  (0.85 on, 0.5 
off) x3 + 1s gap NFPA - 
Temporal Coded 

  

0 0 1 1 0 0 

44 

14 

1000/2000Hz @ 1Hz 
Singapore 

  

1 0 1 1 0 0 

23 

35 

15 

300Hz Continuous 

  

0 1 1 1 0 0 

44 

24 

35 

16 

440Hz Continuous 

  

1 1 1 1 0 0 

44 

24 

35 

17 

470Hz Continuous 

  

0 0 0 0 1 0 

44 

24 

35 

18 

500Hz Continuous IMO code 
2 (Low) 

  

1 0 0 0 1 0 

44 

24 

35 

19 

554Hz Continuous 

  

0 1 0 0 1 0 

64 

24 

35 

20 

660Hz Continuous 

  

1 1 0 0 1 0 

44 

24 

35 

21 

800Hz IMO code 2 (High) 

  

0 0 1 0 1 0 

44 

24 

35 

22 

1200Hz Continuous 

  

1 0 1 0 1 0 

44 

24 

35 

23 

2000Hz Continuous 

  

0 1 1 0 1 0 

15 

35 

24 

2400Hz Continuous 

  

1 1 1 0 1 0 

48 

20 

35 

25 

440 @0.83Hz (50 
cycles/minute) Intermittent 

  

0 0 0 1 1 0  

44 

26 

470 @0.9Hz - 1.1s 
Intermittent 

  

1 0 0 1 1 0 

44 

27 

470Hz @5Hz - (5 
cycles/second) Intermittent 

  

0 1 0 1 1 0 

44 

28 

544Hz @ 1.14Hz - 0.875s 
Intermittent 

  

1 1 0 1 1 0 

44 

24 

29 

655Hz @ 0.875Hz 
Intermittent 

  

0 0 1 1 1 0 

44 

30 

660Hz @0.28Hz - 1.8sec on, 
1.8sec off Intermittent 

  

1 0 1 1 1 0 

44 

24 

31 

660Hz @3.34Hz - 150mS on, 
150mS off

 Intermittent

 

  

0 1 1 1 1 0 

30 

24 

1000Hz

 

1000Hz

1s

1s

544Hz

440Hz

0.1s

0.4s

1500Hz

500Hz

0.5s

0.5s

1.5s

0.5s

0.5s

0.5s

1500Hz

500Hz

2s

1s

1200Hz

500Hz

3.3s

0.5s

1s

1s

1s

7s

7s

1s

1s

1s

1s

1s

1s

1s

1000Hz 1s

1s

1s

1s

0.5s

0.5s

0.5s

1.5s

420Hz 0.5s

0.5s

1000Hz 0.5s

0.5s

0.5s

0.5s

0.5s

1.5s

775Hz

422Hz

0.85s

0.5s

0.85s

0.5s

0.85s

1.5s

2000Hz

1000Hz

1s

300Hz

 

440Hz

 

470Hz

 

500Hz

 

554Hz

 

660Hz

 

800Hz

 

1200Hz

 

2000Hz

 

2400Hz

 

440Hz

0.6s

0.6s

470Hz 0.55s

0.55s

470Hz

0.1s

0.1s

470Hz 0.43s

0.44s

655Hz

0.57s

0.57s

660Hz

1.8s

1.8s

660Hz 0.15s

0.15s

500Hz

 

1s

 

1200Hz

 

Содержание D2xC1

Страница 1: ...NOWN TO BE FREE OF IGNITIBLE CONCENTRATIONS 3 Ratings and Markings 3 1 ATEX IECEx certification The D2xS1 alarm horn complies with the following standards EN60079 0 2012 IEC60079 0 ed 6 0 2011 06 EN60...

Страница 2: ...cable entry and or blanking devices during installation 3 7 Electrical Ratings Part No Nominal Voltage Nominal Current Voltage Range Max Current D2xS1DC024 24Vdc 313mA 10 30Vdc 313mA 24Vdc D2xS1DC048...

Страница 3: ...ations inspection and maintenance Units must not be opened while an explosive atmosphere is present If opening the unit during maintenance operations a clean environment must be maintained and any dus...

Страница 4: ...ply terminals see fig 5 8 3 AC Units Second Third and Fourth Stage Tone Selection To select the second third and fourth stage tones on the D2xS1 AC alarm horns Stage two S2 operation Power L and N lin...

Страница 5: ...se see fig 8 for DC fig 5 for AC The earth conductor should be at least equal in size and rating to the incoming power conductors The internal earth bonding wire connects the PCBA earth terminal to th...

Страница 6: ...f x3 1s gap ISO 8201 Temporal Pattern 0 1 0 1 0 0 44 1 8 12 1000Hz 0 5s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 1 1 0 1 0 0 44 1 8 13 422 775Hz 0 85 on 0 5 off x3 1s gap NFPA Temporal Coded 0...

Страница 7: ...44 24 12 49 560 1055Hz 0 18Hz Sweeping 0 0 0 0 1 1 44 24 12 50 560 1055Hz 3 3Hz Sweeping 1 0 0 0 1 1 44 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 44 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0 1...

Отзывы: