E2S D2xC1 Скачать руководство пользователя страница 3

__________________________________________________________________________________________________________________ 

European Safety Systems Ltd.

   Impress House, Mansell Road, Acton, London W3 7QH           [email protected]              Tel: +44 (0)208 743 8880 

                                                                                                                                                             www.e-2-s.com             Fax: +44 (0)208 740 4200 
Document No. D189-00-001-IS     Issue:  9                        01-06-16               Sheet 3 of 7 

 

(Ingress Protection) rating is required then a suitable sealing 
washer must be fitted under the cable gland. For use in 
explosive gas atmospheres a  minimum ingress protection 
rating of IP54 must be maintained.  For use in explosive dust 
atmospheres a minimum ingress protection rating of IP64 must 
be maintained. 

 

Only the front cover is to be used for access to the enclosure 
for installation, service and maintenance.  Once the product is 
opened, the Type Rating cannot be maintained anymore 
unless a full verification of the gasket material is done and 
there is no damage. 
 
Connections are to be made into the terminal blocks using 
solid or stranded wire, sizes 0.5-2.5mm2  / AWG 20-14. Wire 
insulation needs to be stripped 6-7mm. Wires may be fitted 
securely with crimped ferrules. Terminal screws need to be 
tightened down with a tightening torque of 0.56 Nm / 5 Lb-in. 
Internal  earthing  connections should be made to the Internal 
earth terminal on the PCBA. The earth conductor should be at 
least equal in size and rating to the incoming power 
conductors.  The internal earth  bonding wire connects the 
PCBA  earth  terminal to the internal earth  terminal in the 
enclosure back box. 

 

External earthing connections should be made to the M5 earth 
stud, using a ring crimp terminal to secure the earth conductor 
to the earth stud. The external earth conductor should be at 
least 4mm

2

 / AWG 11 in size. 

 

Check that the earth bonding wire between the two castings is 
secure and the ‘O’ ring seal is in place and in good condition. 

 
4.2 Maintenance, Repair and Overhaul 

 
Maintenance, repair and overhaul of the equipment should only 
be carried out by suitably qualified personnel in accordance 
with the current relevant standards: 
 
EN60079-19 / IEC60079-19  

Explosive atmospheres - 

Equipment repair, overhaul and reclamation 
EN 60079-17/ IEC60079-17 

Explosive atmospheres - 

Electrical installations inspection and maintenance 
 
Units must not be opened while an explosive atmosphere is 
present. 
 
If opening the unit during maintenance operations a clean 
environment must be maintained and any dust layer removed 
prior to opening the unit. 
 
Electrostatic charging hazard - Clean only with a damp cloth 
 

5)  Installation 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig. 1 Fixing locations. 

 

D2xS1  alarm horn  should only be installed by trained 
competent personnel. 
 

5.1 Mounting 

 
The D2xS1 alarm horn  may be secured to any flat surface 
using the two 9.7 x 6.7mm, 147mm pitch fixing holes. The 
enclosure provides IP66 protection and is suitable for 
installation in exterior locations providing it is positioned so that 
water cannot collect in the horn, and the cable entry is sealed. 

 
 
5.2 Installation procedure 
 

a)  Remove  Secure the D2xS1 alarm horn  to a flat 

surface 

via the two 9.7 x 6.7mm, 147mm pitch fixing holes in 

the mounting feet. 

b)  Remove the front of the alarm horn by unscrewing the 

four captive cover screws and pulling the front away 

from the enclosure.  

c)  Fit an M20x1.5 suitably rated, certified cable gland or 

conduit entry into the hole in the enclosure and 

connect the field wiring to the appropriate alarm horn 

terminals as shown in section 9  and fig 8 (DC) or 

section 8 fig 5 (AC) of this manual. The power supply 

terminals are duplicated so that alarm horns may be 

connected in parallel and for DC units only an end of 

line monitoring resistor may be fitted.  If the second 

M20x1.5 entry is not used a suitably rated, certified 

stopping plug must always be fitted. 

d)  Select the required output tone by positioning the six 

switches as shown in Table 1 and Fig 2.  

e)  Adjust the internal volume control to provide the 

required sound level. (Refer to section 6) 

f) 

Check that the O-ring seal in the front cover is in good 

condition and not damaged. 

g)  Replace the front of the alarm horn  and tighten the 

four captive cover screws. 

 

6)  Volume Control

 

 

The output level of the D2xS1 alarm horn  can be set by 
adjusting the volume control potentiometer (see Fig 2). For 
maximum output, set the potentiometer fully clockwise. 

 

Fig. 2 Location of field controls 

 

7)  Cable Routing and Tone Selection 

 

7.1 Cable Routing 
 

Due to the compact design of the D2x units, it is important that 
the user strips off the outer sheath and biases any cables over 
the size of 1mm

2

 as shown below. 

Volume 
Control 

Tone Setting 
Switches 1-6 

(See tone 
selection table) 

Содержание D2xC1

Страница 1: ...NOWN TO BE FREE OF IGNITIBLE CONCENTRATIONS 3 Ratings and Markings 3 1 ATEX IECEx certification The D2xS1 alarm horn complies with the following standards EN60079 0 2012 IEC60079 0 ed 6 0 2011 06 EN60...

Страница 2: ...cable entry and or blanking devices during installation 3 7 Electrical Ratings Part No Nominal Voltage Nominal Current Voltage Range Max Current D2xS1DC024 24Vdc 313mA 10 30Vdc 313mA 24Vdc D2xS1DC048...

Страница 3: ...ations inspection and maintenance Units must not be opened while an explosive atmosphere is present If opening the unit during maintenance operations a clean environment must be maintained and any dus...

Страница 4: ...ply terminals see fig 5 8 3 AC Units Second Third and Fourth Stage Tone Selection To select the second third and fourth stage tones on the D2xS1 AC alarm horns Stage two S2 operation Power L and N lin...

Страница 5: ...se see fig 8 for DC fig 5 for AC The earth conductor should be at least equal in size and rating to the incoming power conductors The internal earth bonding wire connects the PCBA earth terminal to th...

Страница 6: ...f x3 1s gap ISO 8201 Temporal Pattern 0 1 0 1 0 0 44 1 8 12 1000Hz 0 5s on 0 5s off x3 1s gap ISO 8201 Temporal Pattern 1 1 0 1 0 0 44 1 8 13 422 775Hz 0 85 on 0 5 off x3 1s gap NFPA Temporal Coded 0...

Страница 7: ...44 24 12 49 560 1055Hz 0 18Hz Sweeping 0 0 0 0 1 1 44 24 12 50 560 1055Hz 3 3Hz Sweeping 1 0 0 0 1 1 44 24 12 51 600 1250Hz 0 125Hz Sweeping 0 1 0 0 1 1 44 24 12 52 660 1200Hz 1Hz Sweeping 1 1 0 0 1...

Отзывы: