Fig. 7a DC Terminals
Fig. 7b Beacon DC Terminals
13. Settings
13.1 Tone Settings
The sounders have 32 different tones that can be selected for
the first stage alarm. The sounders can then be switched to
sound second and third stage alarm tones. The tones are
selected by operation of a DIP switch on the pcb for both DC
and AC units. The tone table D210-95-001-IS shows the switch
positions for the 32 tones and which tones are available for the
second and third stages. To operate the sounder on stage one
simply connect the supply voltage to the normal supply
terminals (+ve and
–ve for DC units, L and N for AC units).
Refer to wiring schematics D210-06-601 (DC) or D210-06-605
(AC).
Default =
Tone 1
0 0 0 0 0 0
(ON = 1, OFF = 0)
Figure 8: DIP switch configuration
13.2
Telephone Setting DIP & Continuous or
Pulse Sounder Beacon Operation
The BExCTS110-05D combined sounder / beacon has a
number of modes of operation. The sounder and beacon can
be set individually to either run continuously or pulsed at the
cadence of the ringing tone.
This is set by setting the DIP switches on the Telephone pcb
(see figures 5a & 7a).
The Telephone Selection Table on page seven shows the
switch positions 1 - 4 for the country setting and switch 5 for
the beacon continuous or pulse mode and switch 6 for the
sounder continuous or pulse mode.
When making any
changes to the country selection, the unit needs to be de-
energised for a minimum of 2 minutes for the changes to
take effect
.
When pulse mode of operation is selected the tone, pattern will
pulse on and off following the telephone input signal. Note if
pulsed tone operation is selected it is advisable not to select
any of the intermittent tones, such as tone 11.
The beacon will flash at the ringing cadence if pulse is
selected.
13.3
Volume Control
The output level of the BEx sounder can be set by adjusting
the volume control potentiometer (see Fig 9a/9b) with the
exception of 12V DC units. For maximum output, set the
potentiometer fully clockwise.
BExCTS110-05D AC
Fig. 9a Location of Volume Control Potentiometer
Warning - High noise levels above 85dB(A)
during operation. High levels of noise may
cause hearing loss, wear suitable ear
protection when equipment is in operation.
Volume Control
Potentiometer
Volume Control
Potentiometer
Volume Control
DIP Switch
DC
Terminals
Stage
Headers
S2
S3
-
+
-
-
+
+
Interconnecting Terminals
to sounder PCB
(simultaneous
mode of operation)
TB1 Telephone
Signal
Input Terminals
TB3 Sounder
Mains Supply
Output L
Telephone Setting DIP Switch
TB2 Beacon
Mains Supply
Output L