Telephone Selection Settings

 

DIP Switch                                    

Settings

 

DIP Switch                                    

Settings

 

Dialing Country Setting 

1    2   3   4  

5   6  
 

Australia 
Ireland 
New Zealand 
Singapore 
South Africa 
UK 

0    0   0   0

 

  
 

Belgium 
Canada 
Cyprus 
Hong Kong 
Spain 
Turkey 
USA 

1    0   0   0 

 

Czech Republic 
Finland 
France 
Germany 
Greece 
Italy 
Luxemburg 
Netherlands 
Norway 
Switzerland 

0    1   0   0 

 

Austria 
Iceland 
Portugal  
Sweden 

1    1   0   0  

 

Denmark 

0    0   1   0  

 

Pulse or Continuous Setting 

 

 

Beacon & Sounder Continuous 

 

0    0   

Beacon Continuous, Sounder Pulsed 

 

0    1 

Beacon Pulsed, Sounder Continuous 

 

 

1    0 

Beacon & Sounder Pulsed 

 

1    1 

Содержание BExCTS110-05D-P

Страница 1: ...126V BExCTS110 05DPAC230 BExCTS110 05DPAC230 R 230Vac 56mA 55mA 253V Max Tone 4 Nom Tone 44 The table shows the input current taken by the various units The current levels shown above are for the 440H...

Страница 2: ...s air mixture not likely to occur in normal operation and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group IIB Ethylene Temperature Classification for Gas Applicati...

Страница 3: ...it cannot move in service Fig 1a Fixing Location for Combined Flare Fig 1b Fixing Location for Combined Radial 7 Access to the Flameproof Enclosure To access the Ex d chamber remove the four M6 hexago...

Страница 4: ...the stainless steel M4 flat washer is between the incoming earth wire and the enclosure Internal earthing connections should be made to the Internal Earth terminal in the base of the housing using a...

Страница 5: ...g Diagram Fig 5a Sounder AC Terminals Fig 5b Beacon AC Terminals 12 DC Wiring Four connections must be made to the BExCTS110 05D DC unit A power supply input cable should enter the enclosure via one o...

Страница 6: ...cb see figures 5a 7a The Telephone Selection Table on page seven shows the switch positions 1 4 for the country setting and switch 5 for the beacon continuous or pulse mode and switch 6 for the sounde...

Страница 7: ...ixtures 15 Maintenance Overhaul Repair Maintenance repair and overhaul of the equipment should only be carried out by suitably qualified personnel in accordance with the current relevant standards EN6...

Страница 8: ...etting 1 2 3 4 5 6 Australia Ireland New Zealand Singapore South Africa UK 0 0 0 0 Belgium Canada Cyprus Hong Kong Spain Turkey USA 1 0 0 0 Czech Republic Finland France Germany Greece Italy Luxemburg...

Страница 9: ...mittent 660Hz 1 8s on 1 8s off 1 0 0 0 1 0 2 5 19 1400Hz to 1600Hz sweeep up over 1s 0 1 0 0 1 0 2 5 1600Hz to 1400Hz sweep down over 0 5s 20 Continuous 660Hz 1 1 0 0 1 0 2 5 21 Alternating 554 440Hz...

Страница 10: ...DRAWN WEIGHT Kg SURFACE FINISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210...

Страница 11: ...ISH MATERIAL ALTERNATIVE MATERIAL SHEET SCALE TITLE A3 IF IN DOUBT ASK DO NOT SCALE ALL DIMENSIONS IN MM DRAWING NUMBER A B C D E F G 10 9 G F E 7 8 6 5 D C 1 3 4 2 A B D210 06 685 R S RAIT B ISARD R...

Страница 12: ...cation Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 2813 CSA Group Netherlands B V Utrechtseweg 310 6812 AR Arnhem Ne...

Страница 13: ...te and Place of Issue London 21 05 2020 EU Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the...

Страница 14: ...X2639X Notified Body for Quality Assurance Notification Conformity to EU type based on quality assurance of the production process Module D Sira Certification Service Notified Body No 0518 Rake Lane E...

Страница 15: ...nd Place of Issue London 12 09 2022 UKCA Declaration of Conformity On behalf of European Safety Systems Ltd I declare that on the date the equipment accompanied by this declaration is placed on the ma...

Страница 16: ...Page left Intentionally blank...

Отзывы: