INSTRUCTION MANUAL (ATEX / IECEx) 

BExDCS110-L1D 

Flameproof Combined Sounder / LED Beacon 

 
 
 
 
 

1) Introduction 

 
The BExDCS110-L1D is a flameproof combined sounder / 
LED beacon which is certified to meet the requirements of the 
ATEX directive 94/9/EC and the IECEx Scheme. The 
combined unit produces both loud audio warning signals and 
visual warning signals that can be used in hazardous areas 
where potentially flammable atmospheres may be present. 
Thirty-two different first stage audio alarm sounds can be 
selected by internal switches, and each one can be externally 
changed to a second or third stage alarm sound  (

see tone 

table on Page 5

).  The sounder produces output levels in the 

110dB(A) range. The beacon section has nine different 
selectable flash patterns including a steady ON state and can 
also be remotely switched to a second and third flash pattern 
(

see flash pattern table on page 5).

 The unit can be used in 

Zone 1 and Zone 2 areas with gases in groups IIA and IIB 
and with Temperature Classifications of T1, T2, T3 and T4 
and can also be used in Zone 21 and Zone 22 areas for 
combustible dusts and has an IP rating of IP 67 and a surface 
temperature rating of T115ºC (T100ºC at +55ºC). 
 

2) Marking 

 
All units have a rating label, which carries the following 
important information:- 
 
Unit Type No.     

       BExDCS110-L1D

 

 
Input Voltage:    DC Units    12V  or 24V  or  48V 

            AC Units         230V or 115V 

 

        

Codes:   Ex d IIB T4 for Ta –50°C to +70ºC 

Ex tD A21 IP6X T115°C based on max Ta of +70°C 

 

       

 

            

Certificate No.

 KEMA 

01ATEX2223X 

IECEx KEM 10.0025X 

 

 

 

 

 

“Warnings”

 

 

DO NOT OPEN WHEN AN EXPLOSIVE  

                         

     GAS ATMOSPHERE IS PRESENT 

 

      COVER BOLTS CLASS A4-80 

 

                    USE HEAT RESISTING CABLES AND        

                   CABLE GLANDS (Rated 110ºC) AT  

                       AMB. TEMPERATURES OVER 40ºC 

 
Year of Construction /  
Serial No.       

 

 i.e.  10 / 1DCS52000001 

 

3) 

Type Approval Standards

 

 
The units have an EC Type examination certificate issued by 
KEMA and have been approved to the following standards:- 

 
 
 
 
 
 
 
 

EN60079-0:2006   IEC60079-0:2004 (Ed4)

      

General Requirements

 

EN60079-1:2007   IEC60079-1:2007

 

(Ed6)

        Flameproof Enclosure ‘d’ 

EN61241-0:2006   IEC61241-0:2004 (Ed1)       Dust General 

          Requirements 

EN61241-1:2004   IEC60079-1:2004 (Ed1)       Dust Enclosures tD 

 

4)

 Installation Requirements 

 
The unit must be installed in accordance with the latest 
issues of the relevant parts of the EN60079 specifications or 
the equivalent IEC specifications – Selection, Installation and 
maintenance of electrical apparatus for use in potentially 
explosive atmospheres (other than mining applications or 
explosive processing and manufacture):- 
 

EN60079-14:2008

    

Electrical Installations in Hazardous 

IEC60079-14:2007 (Ed4) 

Areas (other than mines)

 

 

EN60079-10:2003

   

Classification of Hazardous Areas

 

IEC60079-10:2008 (Ed1) 

 
The installation of the unit must also be in accordance with 
any local codes that may apply and should only be carried 
out by a competent electrical engineer who has the 
necessary training. 

 

4) 

Zones, Gas Group, Category and Temperature 
Classification 

 

The BExDCS110-L1D unit has been certified Ex d IIB T4 for 
Ta –50°C to +70ºC for gas and Ex tD A21 IP6X T115ºC 
based on max. Ta of +70ºC for dust. This means that the 
units can be installed in locations with the following 
conditions:- 
  

Area Classification: 

 

Zone 1 

Explosive gas air mixture likely to occur in 
normal operation. 

Zone 2 

Explosive gas air mixture not likely to occur, 
and if  it does, it will only exist for a short time. 

  

Gas Groupings: 

 

Group IIA 

Propane 

Group IIB 

Ethylene 

 

 

 

Temperature Classification: 

 

T1 400

o

 C  

T2 300

o

 C 

T3 200

o

 C 

T4 135

o

 C 

 

Ambient Temperature Range: 

 

   

         -50

°

C to +70

°

0518 

II 2G 

Epsilon x: 
Equipment Group 
and Category: 

CE Marking: 
Notified Body No. 

Содержание BE DCS110-L1D Series

Страница 1: ...gs DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS PRESENT COVER BOLTS CLASS A4 80 USE HEAT RESISTING CABLES AND CABLE GLANDS Rated 110 C AT AMB TEMPERATURES OVER 40 C Year of Construction Serial No i...

Страница 2: ...of joints should be inspected to ensure that they are clean and that they have not been damaged during installation Also check that the earth bonding wire between the two casting sections is secure an...

Страница 3: ...standard EN60079 14 2008 IEC60079 14 SAFETY WARNING If the unit is used at high ambient temperatures i e over 40 C then the cable entry temperature may exceed 70 C and therefore suitable heat resisti...

Страница 4: ...pply voltage to the normal supply terminals ve and ve for DC units L and N for AC units The operation of the second and third stages is different for DC and AC units DC Units Second and Third Stage To...

Страница 5: ...DC units have a blocking diode fitted in their supply input lines on both the sounder section and the LED beacon section An end of line monitoring diode or an end of line monitoring resistor can be co...

Страница 6: ...eacon PCB L L N C S2 S3 L N C S2 S3 C L N N S2 S3 C L N C S2 S3 L N C S2 S3 L N C S2 S3 Beacon Connections Sounder Connections Beacon PCB Sounder PCB L N C S2 S3 S3 S2 Unit No 1 Unit No 2 Unit No 3 L...

Страница 7: ...ccleston Chester CH4 9JN UK Quality Assurance Notification SIRA 05 ATEX M342 Provisions fulfilled by the equipment ll2 G Ex d llB T4 ll 2 D Ex tD A21 IPGX T100 C or T115 C Standards applied EN 60079 0...

Отзывы: