LED BEACON SECTION CONNECTIONS 
The cable supply connections are made into the terminal 
blocks on the electronic pcb assembly located in the 
flameproof LED beacon section enclosure, see section 8 of 
this manual for access to the flameproof enclosure. The AC 
unit has two live terminals and two neutral terminals for the 
input and output supply wiring and the DC unit has two +ve 
terminals and two -ve terminals for the input and output 
supply wiring. Both units have S2 and S3 terminals to 
remotely change the flash pattern, see section 16 of this 
manual. 
 
Wires having a cross sectional area of up to 4mm² can be 
connected to each terminal way. When connecting wires to 
the terminals great care should be taken to dress the wires so 
that wires do not exert excess pressure on the terminal 
blocks. This is particularly important when using cables with 
large cross sectional areas such as 2.5mm² and above. 
 
 
 

N   L

 

 
 
 

+   +   -    -   

S2  S3

+   -

 

 

12) 

Tone Selection and 2nd and 3rd Stage Alarms

 

 

The BExCS110-L1D sounder section has 32 different tones 
that can be selected for the first stage alarm. The sounders 
can then be switched to sound second and third stage alarm 
tones. The tones are selected by operation of a DIP switch on 
the sounder pcb for both DC and AC units. The tone table on 
page five shows the switch positions for the 32 tones and 
which tones are available for the second and third stages. To 
operate the sounder on stage one simply connect the supply 
voltage to the normal supply terminals (+ve and –ve for DC 
units,  L and N for AC units).  

 
The operation of the second and third stages is different for 
DC and AC units. 
 
DC Units Second and Third Stage Tone Selection 
 
The BExCS110-L1D DC sounder section has the facility to 
use ve or –ve switching to change the tone to the 
second and third stages. For –ve switching connect the two 
headers on the pcb to the left-hand (marked –ve) and centre 
pins. For +ve switching connect the headers to the right hand 
(ve) and the centre pins. To change to the second 
stage tone, connect either a -ve or +ve supply line to terminal 
S2, depending on which switching mode is being used while 
maintaining the dc supply to the +ve and –ve terminals. 
Similarly for the third stage tone, connect a -ve or +ve supply 
line to terminal S3. The supply to the S3 terminal will 
automatically override a supply to the S2 terminal. 
 
AC Units Second and Third Stage Tone Selection 
 
To select the second and third stage tones on the 
BExDCS110-L1D AC sounder section, the Common (C) 
terminal on the three way terminal block on the pcb is 
connected to the S2 terminal for the second stage tone and 
the S3 terminal for the third stage tone. 
 

 

 
 

Volume Control

 

 

The BExDCS110-L1D sounder section, with the exception of 
12V DC units, has a volume control to adjust the output level. 
To set the required output level, adjust the potentiometer on 

Figure 7 

Figure 6 

BExDCS110-L1D  DC Sounder Section 

BExDCS110-L1D  AC Sounder Section 

Volume Control 

DIP Switch 

DIP Switch 

Volume Control 

DC Input 
Terminals 

Stage Headers 

Stage Terminals 

AC Input 
Terminals 

 
S2 
S3

 


+

 

       S2 
       S3 
        C 
 
 
        N 
        L

 

Figure 4 

AC Input 
Terminals 

Interconnecting 
Terminals to 
sounder pcb 
(simultaneous 
mode of 
operation) 

BExDCS110-L1D  AC LED Beacon Section 

Flash Pattern 
Pin Headers 

DC Input 
Terminals 

Figure 5 

Flip / Flop 
Pin Header 

BExDCS110-L1D  DC Beacon Section 

Interconnecting 
Terminals to 
sounder pcb 
(simultaneous 
mode of 
operation) 

2nd and 3

rd

 Stage 

Terminals 

Содержание BE DCS110-L1D Series

Страница 1: ...gs DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS PRESENT COVER BOLTS CLASS A4 80 USE HEAT RESISTING CABLES AND CABLE GLANDS Rated 110 C AT AMB TEMPERATURES OVER 40 C Year of Construction Serial No i...

Страница 2: ...of joints should be inspected to ensure that they are clean and that they have not been damaged during installation Also check that the earth bonding wire between the two casting sections is secure an...

Страница 3: ...standard EN60079 14 2008 IEC60079 14 SAFETY WARNING If the unit is used at high ambient temperatures i e over 40 C then the cable entry temperature may exceed 70 C and therefore suitable heat resisti...

Страница 4: ...pply voltage to the normal supply terminals ve and ve for DC units L and N for AC units The operation of the second and third stages is different for DC and AC units DC Units Second and Third Stage To...

Страница 5: ...DC units have a blocking diode fitted in their supply input lines on both the sounder section and the LED beacon section An end of line monitoring diode or an end of line monitoring resistor can be co...

Страница 6: ...eacon PCB L L N C S2 S3 L N C S2 S3 C L N N S2 S3 C L N C S2 S3 L N C S2 S3 L N C S2 S3 Beacon Connections Sounder Connections Beacon PCB Sounder PCB L N C S2 S3 S3 S2 Unit No 1 Unit No 2 Unit No 3 L...

Страница 7: ...ccleston Chester CH4 9JN UK Quality Assurance Notification SIRA 05 ATEX M342 Provisions fulfilled by the equipment ll2 G Ex d llB T4 ll 2 D Ex tD A21 IPGX T100 C or T115 C Standards applied EN 60079 0...

Отзывы: